Near-diffraction limited direct imaging of patterned light fields for trapping (Conference Presentation)

Guillaume Gauthier, Issac Lenton, Mark A. Baker, Matthew J. Davis, Halina H. Rubinsztein-Dunlop, Tyler W. Neely

Published Apr 28, 2017• 0 citations
Publisher

Abstract

Configurable trapping potentials are of great interest in cold atom physics, as they enable production of dynamical highly flexible fields that exhibit unprecedented stability and diverse geometries. Direct imaging can be used to create large area trapping potentials but is often overlooked due to its inability to correct for wavefront aberrations of the optical system [1]. This need not be a major disadvantage for a well-corrected optical system and brings advantages including the simplicity and speed of direct imaging. This is in contrast to the Fourier plane method which requires complex calculations to generate proper holograms and suffers from phase defects and speckle. For applications in cold atom trapping, these effects are especially detrimental as the atoms are sensitive to perturbations at the ~1% level of the optical potential. Our approach uses off-the-shelf lenses and microscope objectives and is able to achieve 630(10) nm full width half maximum (FWHM) patterning resolution using a 0.45 NA objective, within 5% of the diffraction limit of the system, while imaging through 1.25 mm of glass. The light field patterning is done using a digital micromirror device (DMD) which allows for dynamic trapping potentials due to its ability to store 13,889 frames and its 22 kHz full frame refresh rate. We use this method to pattern planar potentials for the purpose of cold atom experiments and have found that for atoms, which tend to respond relatively slowly to perturbations, it is possible to combine half-toning and time averaging to produce grey scale patterns, additionally allowing for pattern correction [2]. [1] P. C. Mogensen and J. Glückstad, Optics Communications 175, 75–81 (2000). [2] G. Gauthier, I. Lenton, N. McKay Parry, M. Baker, M. J. Davis, H. Rubinsztein-Dunlop, and T. W. Neely, arXiv preprint arXiv:1605.04928 (2016).

DOI
10.1117/12.2251851

Related papers

Configurable and dynamic trapping potentials for ultracold atoms using a DMD device (Conference Presentation)

Tyler W. Neely, Guillaume Gauthier, Isaac C. D. Lenton +3 more

The implementation of spatial light modulators (SLMs) in quantum gas experiments has allowed the realization of ever more complex trapping geometries. As ultracold atoms may be sensitive to perturbations of the trapping potential at the 1% level, the high contrast ratios of digital micromirror devices are proving advantageous for use in optical trapping. Our laboratory pursues configurable traps based on the direct (nearly diffraction limited) imaging of a digital micromirror device (DMD). We achieve highly flexible potentials using commercially available microscope objectives external to our vacuum chamber that directly project the DMD to the atom plane, producing optical traps over an area of 130 μm × 200 μm, with a resolution of 630(10) nm full width at half maximum (FWHM) at 532 nm illumination. We combine these potentials with a horizontally propagating TEM00 or TEM01 Hermite-Gaussian optical sheet that provides vertical confinement. With the dynamic control enabled by the maximum full-frame rate of 20 KHz and on-board storage of <13,000 frames of the DMD, we study the transport of atoms and superfluid dynamics in configurable trapping geometries. Using the fast frame rate of the DMD we also produce intermediate grey levels that complement half-toning techniques for producing optimized grayscale patterns.

•May 3, 2017•0 citations

Direct imaging of a digital-micromirror device for configurable microscopic optical potentials

G. Gauthier, Isaac C. D. Lenton, Nicholas McKay Parry +4 more

Programable spatial light modulators (SLMs) have significantly advanced the configurable optical trapping of particles. Typically, these devices are utilized in the Fourier plane of an optical system, but direct imaging of an amplitude pattern can potentially result in increased simplicity and computational speed. Here we demonstrate high-resolution direct imaging of a digital micromirror device (DMD) at high numerical apertures (NA), which we apply to the optical trapping of a Bose-Einstein condensate (BEC). We utilise a (1200 x 1920) pixel DMD and commercially available 0.45 NA microscope objectives, finding that atoms confined in a hybrid optical/magnetic or all-optical potential can be patterned using repulsive blue-detuned (532 nm) light with 630(10) nm full-width at half-maximum (FWHM) resolution, within 5% of the diffraction limit. The result is near arbitrary control of the density the BEC without the need for expensive custom optics. We also introduce the technique of time-averaged DMD potentials, demonstrating the ability to produce multiple grayscale levels with minimal heating of the atomic cloud, by utilising the high switching speed (20 kHz maximum) of the DMD. These techniques will enable the realization and control of diverse optical potentials for superfluid dynamics and atomtronics applications with quantum gases. The performance of this system in a direct imaging configuration has wider application for optical trapping at non-trivial NAs.

arXiv:1605.04928•Optica•Oct 10, 2016•237 citations

Microscopic trapping and high-resolution imaging of ultra cold Rydberg atoms

Harish Rathore

In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.

•Jul 22, 2020•0 citations

Sculpted light in optical micromanipulation and quantum atom optics

Halina H. Rubinsztein-Dunlop

Sculpted light refers to the generation of custom designed light fields. These light fileds can be applied in many diverse fields ranging from interrogating single atoms or atom assembly to using these fields for optical micromanipulation and optical tweezers as well as creating new quantum devices and sensors. We consider here the study and application of light with structured intensity, polarization and phase. We can create custom fields in multiple planes using dynamic and geometric phase control. As an example, the use of sculpted light in imaging has led to superresolution microscopy developed by Betzig, Hell and Moerner (2014 Nobel prize in Chemistry). Sculpted light can be generated using several technologies. These are spatial light modulators (SLM) and Digital Micromirror Devices (DMD) that enable the production of configurable and flexible confining potentials at the nano and micron-scale. Sculpted light can also be produced using time averaged methods such as Acousto-Optics Modulators (AOM), enabling production of highly configurable time-averaged traps. All these methods achieve dynamical and flexible sculpted light fields and enable imaging of the amplitude patterns, phase and polarization. Using these sculpted light we can produce novel optical potentials which can be used for intricate studies of light -matter interactions in a variety of environments. We will describe their use ranging from studies such as quantum thermodynamics using ultra cold atoms to trapping and manipulating nano and micron-size objects or even making measurements in-vivo inside biological cells.

SPIE Conference on Quantum and Nonlinear Optics•Dec 31, 2022•0 citations

Design of compact high resolution imaging system for cold atom experiments

Xiaoyang Shen, Yi-Hao Cheng, Xia Lin

In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.

Acta Physica Sinica•Dec 15, 2023•0 citations

Ultrafast and high resolution spatial light modulation for cold atoms

Alexander Dennisovich Deters, Yanfei Li, Alexander Douglas +2 more

Programmable arrays of ultracold atoms are a leading platform for quantum computation and simulation, enabling state-of-the-art implementations of quantum error correction, and analog simulations of Hubbard models that address open problems in condensed matter physics. In these systems, all local control is mediated through precisely shaped optical fields, and so the challenge of managing many-body quantum states becomes an exercise in optical design. In particular, one wishes for fast, flexible control with low disorder and heating, and access to large arrays with many atoms. An ideal optical system therefore must generate arbitrary patterns with high spatial resolution and low disorder, and alter these patterns on a timescale that is faster than the relevant atomic dynamics. Here, we present an optical system that is comparable to previous approaches in scale, while advancing all other axes. We demonstrate arbitrary pattern generation with $10^{-3}$ intensity resolution, a frame rate of $>84$ MFPS (megaframes per second), and a spatial resolution of $83 \times 52$ beam waists (with $11 \times 52$ waists accessible via a single $40$ GHz electro-optic modulator). These capabilities unlock a new class of experiments. We develop and numerically validate a scheme for fully programmable Hubbard models, with time-dependent control over local chemical potentials, tunneling amplitudes, on-site interactions, and patterns of artificial magnetic flux. The same architecture performs fast, arbitrary permutations of tweezers in 2D, decoupling optical constraints from the design of high-rate error-correcting codes.

physics.atom-phCross-listedarXiv:2608.18071•Aug 19, 2026•3 citations
Configurable trapping potentials are of great interest in cold atom physics, as they enable production of dynamical highly flexible fields that exhibit unprecedented stability and diverse geometries. Direct imaging can be used to create large area trapping potentials but is often overlooked due to its inability to correct for wavefront aberrations of the optical system [1]. This need not be a major disadvantage for a well-corrected optical system and brings advantages including the simplicity and speed of direct imaging. This is in contrast to the Fourier plane method which requires complex calculations to generate proper holograms and suffers from phase defects and speckle. For applications in cold atom trapping, these effects are especially detrimental as the atoms are sensitive to perturbations at the ~1% level of the optical potential. Our approach uses off-the-shelf lenses and microscope objectives and is able to achieve 630(10) nm full width half maximum (FWHM) patterning resolution using a 0.45 NA objective, within 5% of the diffraction limit of the system, while imaging through 1.25 mm of glass. The light field patterning is done using a digital micromirror device (DMD) which allows for dynamic trapping potentials due to its ability to store 13,889 frames and its 22 kHz full frame refresh rate. We use this method to pattern planar potentials for the purpose of cold atom experiments and have found that for atoms, which tend to respond relatively slowly to perturbations, it is possible to combine half-toning and time averaging to produce grey scale patterns, additionally allowing for pattern correction [2]. [1] P. C. Mogensen and J. Glückstad, Optics Communications 175, 75–81 (2000). [2] G. Gauthier, I. Lenton, N. McKay Parry, M. Baker, M. J. Davis, H. Rubinsztein-Dunlop, and T. W. Neely, arXiv preprint arXiv:1605.04928 (2016).
The implementation of spatial light modulators (SLMs) in quantum gas experiments has allowed the realization of ever more complex trapping geometries. As ultracold atoms may be sensitive to perturbations of the trapping potential at the 1% level, the high contrast ratios of digital micromirror devices are proving advantageous for use in optical trapping. Our laboratory pursues configurable traps based on the direct (nearly diffraction limited) imaging of a digital micromirror device (DMD). We achieve highly flexible potentials using commercially available microscope objectives external to our vacuum chamber that directly project the DMD to the atom plane, producing optical traps over an area of 130 μm × 200 μm, with a resolution of 630(10) nm full width at half maximum (FWHM) at 532 nm illumination. We combine these potentials with a horizontally propagating TEM00 or TEM01 Hermite-Gaussian optical sheet that provides vertical confinement. With the dynamic control enabled by the maximum full-frame rate of 20 KHz and on-board storage of <13,000 frames of the DMD, we study the transport of atoms and superfluid dynamics in configurable trapping geometries. Using the fast frame rate of the DMD we also produce intermediate grey levels that complement half-toning techniques for producing optimized grayscale patterns.
Programable spatial light modulators (SLMs) have significantly advanced the configurable optical trapping of particles. Typically, these devices are utilized in the Fourier plane of an optical system, but direct imaging of an amplitude pattern can potentially result in increased simplicity and computational speed. Here we demonstrate high-resolution direct imaging of a digital micromirror device (DMD) at high numerical apertures (NA), which we apply to the optical trapping of a Bose-Einstein condensate (BEC). We utilise a (1200 x 1920) pixel DMD and commercially available 0.45 NA microscope objectives, finding that atoms confined in a hybrid optical/magnetic or all-optical potential can be patterned using repulsive blue-detuned (532 nm) light with 630(10) nm full-width at half-maximum (FWHM) resolution, within 5% of the diffraction limit. The result is near arbitrary control of the density the BEC without the need for expensive custom optics. We also introduce the technique of time-averaged DMD potentials, demonstrating the ability to produce multiple grayscale levels with minimal heating of the atomic cloud, by utilising the high switching speed (20 kHz maximum) of the DMD. These techniques will enable the realization and control of diverse optical potentials for superfluid dynamics and atomtronics applications with quantum gases. The performance of this system in a direct imaging configuration has wider application for optical trapping at non-trivial NAs.
In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.
Sculpted light refers to the generation of custom designed light fields. These light fileds can be applied in many diverse fields ranging from interrogating single atoms or atom assembly to using these fields for optical micromanipulation and optical tweezers as well as creating new quantum devices and sensors. We consider here the study and application of light with structured intensity, polarization and phase. We can create custom fields in multiple planes using dynamic and geometric phase control. As an example, the use of sculpted light in imaging has led to superresolution microscopy developed by Betzig, Hell and Moerner (2014 Nobel prize in Chemistry). Sculpted light can be generated using several technologies. These are spatial light modulators (SLM) and Digital Micromirror Devices (DMD) that enable the production of configurable and flexible confining potentials at the nano and micron-scale. Sculpted light can also be produced using time averaged methods such as Acousto-Optics Modulators (AOM), enabling production of highly configurable time-averaged traps. All these methods achieve dynamical and flexible sculpted light fields and enable imaging of the amplitude patterns, phase and polarization. Using these sculpted light we can produce novel optical potentials which can be used for intricate studies of light -matter interactions in a variety of environments. We will describe their use ranging from studies such as quantum thermodynamics using ultra cold atoms to trapping and manipulating nano and micron-size objects or even making measurements in-vivo inside biological cells.
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.
Programmable arrays of ultracold atoms are a leading platform for quantum computation and simulation, enabling state-of-the-art implementations of quantum error correction, and analog simulations of Hubbard models that address open problems in condensed matter physics. In these systems, all local control is mediated through precisely shaped optical fields, and so the challenge of managing many-body quantum states becomes an exercise in optical design. In particular, one wishes for fast, flexible control with low disorder and heating, and access to large arrays with many atoms. An ideal optical system therefore must generate arbitrary patterns with high spatial resolution and low disorder, and alter these patterns on a timescale that is faster than the relevant atomic dynamics. Here, we present an optical system that is comparable to previous approaches in scale, while advancing all other axes. We demonstrate arbitrary pattern generation with 10−310^{-3}10−3 intensity resolution, a frame rate of >84>84>84 MFPS (megaframes per second), and a spatial resolution of 83×5283 \times 5283×52 beam waists (with 11×5211 \times 5211×52 waists accessible via a single 404040 GHz electro-optic modulator). These capabilities unlock a new class of experiments. We develop and numerically validate a scheme for fully programmable Hubbard models, with time-dependent control over local chemical potentials, tunneling amplitudes, on-site interactions, and patterns of artificial magnetic flux. The same architecture performs fast, arbitrary permutations of tweezers in 2D, decoupling optical constraints from the design of high-rate error-correcting codes.