Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Precision measurement of magnetic field based on the transient process in a K-Rb-^21Ne co-magnetometer

Wei Quan, Kai Wei, Hairong Li

Published Apr 3, 2017• 20 citations
Publisher

Abstract

Ne in steady state is presented. We characterize the dynamics of the coupled spin ensembles by a set of Bloch equations, and formulate the expression of transient output signal. After verifying the stability of this method, the measurement range and error are studied. This method is also verified to be valid in various temperature and pumping light power density.

DOI
10.1364/oe.25.008470

Related papers

Effects of pump laser intensity on the cell temperature working point in a K-Rb- 21 Ne spin-exchange relaxation-free co-magnetometer

Jiasen Ruan, Lihong Duan, Yang Fu +2 more

The cell temperature working point optimization of the spin-exchange relaxation-free (SERF) co-magnetometer is studied theoretically and experimentally in this article. Based on the steady-state solution of the Bloch equations, the steady-state response model of the K-Rb- 21 Ne SERF co-magnetometer output signal with cell temperature is established in this paper. And combined with the model, a method to find the optimal working point of the cell temperature that incorporates the pump laser intensity is proposed. The scale factor of the co-magnetometer under different pump laser intensities and cell temperatures is obtained experimentally, and the long-term stability of the co-magnetometer at the different cell temperatures with corresponding pump laser intensities is measured. The results show that the bias instability of the co-magnetometer is reduced from 0.0311 deg/h to 0.0169 deg/h by obtaining the optimal working point of the cell temperature, which verifies the validity and accuracy of the theoretical derivation and the proposed method.

Optics Express•Feb 6, 2023•12 citations

Simultaneous measurement of magnetic field and inertia based on hybrid optical pumping

Wei Quan, Yang Li, Baiqi Liu

We present a method for simultaneous measurement of magnetic field and inertia by using a hybrid optical pumping of and atoms. The K atoms are directly pumped by a laser and the two species interact with each other by spin exchange and the average magnetization of each other. A simultaneous-measurement model of magnetic field and inertia is proposed based on the coupled spin ensemble. By solving the K-Rb Bloch equation analytically and numerically, we find that the steady-state response for K, Rb transverse polarizations is linearly dependent on magnetic field and inertial rotation rate. The optimal bias magnetic field, suppression of the disturbance magnetic field in the signal, density ratio of K/Rb, and temperature of the cell are carefully analyzed to make the measurement model precise.

Europhysics Letters (EPL)•Jun 1, 2015•18 citations

Precise Determination of Magnetic Gradient Relaxation of Coupled Atomic Spin Ensemble in Spin-Exchange Relaxation-Free Co-Magnetometer

Xiujie Fang, Kai Wei, Wenfeng Fan +5 more

Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation of alkali metal atoms and inert atoms of strongly coupled spin systems under triaxial magnetic field gradients in the K-Rb-21Ne co-magnetometer. The magnetic field gradient relaxation of alkali metal atoms is measured using a step magnetic field modulation method, and the magnetic field gradient relaxation of inert atoms is measured using a combined free induction decay and spin growth method. The method does not require the use of large background magnetic fields and RF fields to maintain the atoms in the SERF state, does not require additional optics, and is not affected by the pumping or detecting of optical power. A kinetic model that considers a large electron-equivalent magnetic field was designed and a gradient relaxation model was developed. The quadratic coefficients of the experimentally measured gradient relaxation curves fit the theoretical model well over the range of the applied magnetic field gradients, confirming the validity of the proposed method.

Photonics•Apr 3, 2023•3 citations

Suppression of Low-Frequency Magnetic Drift Based on Magnetic Field Sensitivity in K-Rb-21Ne Atomic Spin Comagnetometer

Ye Liu, Wenfeng Fan, Yang Fu +3 more

A spin-exchange relaxation-free comagnetometer is a promising high-precision gyroscope as its inertial measurement sensitivity can rival that of existing technologies. The magnetic field error is one of the main factors that limits the long-term stability of the comagnetometer. The steady-state response and frequency response models of a K-Rb-21Ne comagnetometer are modified by considering the spin-exchange rate between the electron spins and the nuclear spins. The modified models are used to redefine the bias magnetic sensitivity of the K-Rb-21Ne comagnetometer and the suppression method of low-frequency magnetic field error is proposed. We demonstrate the magnetic drift suppression method proposed in the article by optimizing the cell temperature and pump laser power density. This study is helpful to improve the rotation measurement performance of the K-Rb-21Ne comagnetometer.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•19 citations

Probe beam influence on spin polarization in spin-exchange relaxation-free co-magnetometers

Yao Wei, Xing Li, Yueyang Zhai +4 more

Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.

Journal of Physics D Applied Physics•Feb 20, 2023•5 citations

In situ measurement of residual magnetic field in SERF atomic magnetometer based on transient response

Di Zhan, Yaoguo Wang, Jixi Lu

Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.

Advanced Sensor Systems and Applications•Nov 20, 2024•0 citations
Ne in steady state is presented. We characterize the dynamics of the coupled spin ensembles by a set of Bloch equations, and formulate the expression of transient output signal. After verifying the stability of this method, the measurement range and error are studied. This method is also verified to be valid in various temperature and pumping light power density.
The cell temperature working point optimization of the spin-exchange relaxation-free (SERF) co-magnetometer is studied theoretically and experimentally in this article. Based on the steady-state solution of the Bloch equations, the steady-state response model of the K-Rb- 21 Ne SERF co-magnetometer output signal with cell temperature is established in this paper. And combined with the model, a method to find the optimal working point of the cell temperature that incorporates the pump laser intensity is proposed. The scale factor of the co-magnetometer under different pump laser intensities and cell temperatures is obtained experimentally, and the long-term stability of the co-magnetometer at the different cell temperatures with corresponding pump laser intensities is measured. The results show that the bias instability of the co-magnetometer is reduced from 0.0311 deg/h to 0.0169 deg/h by obtaining the optimal working point of the cell temperature, which verifies the validity and accuracy of the theoretical derivation and the proposed method.
We present a method for simultaneous measurement of magnetic field and inertia by using a hybrid optical pumping of and atoms. The K atoms are directly pumped by a laser and the two species interact with each other by spin exchange and the average magnetization of each other. A simultaneous-measurement model of magnetic field and inertia is proposed based on the coupled spin ensemble. By solving the K-Rb Bloch equation analytically and numerically, we find that the steady-state response for K, Rb transverse polarizations is linearly dependent on magnetic field and inertial rotation rate. The optimal bias magnetic field, suppression of the disturbance magnetic field in the signal, density ratio of K/Rb, and temperature of the cell are carefully analyzed to make the measurement model precise.
Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation of alkali metal atoms and inert atoms of strongly coupled spin systems under triaxial magnetic field gradients in the K-Rb-21Ne co-magnetometer. The magnetic field gradient relaxation of alkali metal atoms is measured using a step magnetic field modulation method, and the magnetic field gradient relaxation of inert atoms is measured using a combined free induction decay and spin growth method. The method does not require the use of large background magnetic fields and RF fields to maintain the atoms in the SERF state, does not require additional optics, and is not affected by the pumping or detecting of optical power. A kinetic model that considers a large electron-equivalent magnetic field was designed and a gradient relaxation model was developed. The quadratic coefficients of the experimentally measured gradient relaxation curves fit the theoretical model well over the range of the applied magnetic field gradients, confirming the validity of the proposed method.
A spin-exchange relaxation-free comagnetometer is a promising high-precision gyroscope as its inertial measurement sensitivity can rival that of existing technologies. The magnetic field error is one of the main factors that limits the long-term stability of the comagnetometer. The steady-state response and frequency response models of a K-Rb-21Ne comagnetometer are modified by considering the spin-exchange rate between the electron spins and the nuclear spins. The modified models are used to redefine the bias magnetic sensitivity of the K-Rb-21Ne comagnetometer and the suppression method of low-frequency magnetic field error is proposed. We demonstrate the magnetic drift suppression method proposed in the article by optimizing the cell temperature and pump laser power density. This study is helpful to improve the rotation measurement performance of the K-Rb-21Ne comagnetometer.
Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.
Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.