Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Atom Interferometry: A Matter Wave Clock and a Measurement of $\alpha$

Brian Estey, Shau-Yu Lan, Pei-Chen Kuan, Michael Hohensee, Philipp Haslinger, Pauli Kehayias, D. English, Holger M uller

Published Jun 5, 2012• 0 citations
OpenAlex

Related papers

Atom interferometry and coherent matter waves

Arnaud Landragin, Philippe Bouyer

•Dec 1, 2005•1 citation

Atomic Clocks and Atom Interferometry

Christian Bordé

Springer eBooks•Jan 1, 2002•5 citations

Magic-wavelength matter-wave interferometry with optical clock states

Jianing Li, Swarup Das, Xinyuan Ma +4 more

Optical clocks and atom interferometers provide complementary ways to measure time, motion and gravity. Combining these capabilities requires matter-wave beam splitters that manipulate different clock states in the same way, so that optical internal energy becomes a controlled degree of freedom rather than a source of systematic phase shifts. Here we realized a dual matter-wave interferometer operating simultaneously on the two states of the $^{88}$Sr optical clock transition, $^1S_0$ and $^3P_0$. The interferometer is driven by Bragg pulses at the 813 nm magic wavelength, for which the two clock states experience the same optical coupling strength. This realizes a common matter-wave beam splitter for atoms whose internal energies differ by an optical excitation. With a sensitivity of 30 mrad, our measurement is consistent with a zero differential phase shift between the two clock-state Mach-Zehnder interferometers, translating to an absence of state-dependent acceleration in free fall at the level of $10^{-5}$. We further used the same interferometer to measure state-dependent optical dipole forces and determine a tune-out wavelength of the metastable $^3P_0$ state to be 478.95(8) nm. These results establish magic-wavelength clock-state interferometry as a platform for differential force sensing, excited-state polarizability metrology and future quantum-clock tests of gravity.

arXiv:2608.17576•Aug 18, 2026•0 citations

Sagnac Interferometry with a Single Atomic Clock

R. Stevenson, Michael Hush, T. Bishop +2 more

The Sagnac effect enables interferometric measurements of rotation with high precision. Using matter waves instead of light promises resolution enhancement by orders of magnitude that scales with particle mass. So far, the paradigm for matter wave Sagnac interferometry relies on de Broglie waves and thus on free propagation of atoms either in free fall or within waveguides. However, the Sagnac effect can be expressed as a proper time difference experienced by two observers moving in opposite directions along closed paths and has indeed been measured with atomic clocks flown around Earth. Inspired by this, we investigate an interferometer comprised of a single atomic clock. The Sagnac effect manifests as a phase shift between trapped atoms in different internal states after transportation along closed paths in opposite directions, without any free propagation. With analytic models, we quantify limitations of the scheme arising from atomic dynamics and finite temperature. Furthermore, we suggest an implementation with previously demonstrated technology.

arXiv:1504.05530•Physical Review Letters•Oct 13, 2015•59 citations

Atom Interferometry as a Probe of the Terrestrial GMWT Geometric Amplitude Matter-Wave Phase Shifts, Dual-Species Tests, Gradiometry, Source-Mass Measurements, Aharonov–Bohm Phase, Frequency-Shift Outlook, and the Canonical 10−12 Contractive Scale

Rafik Hiahemzizou

This article investigates atom interferometry, precision clocks, resonant cavities, and selected geometry-sensitive anomalies as experimental consistency tests for the Gravitation Matter–Wave Theory (GMWT). The central quantity is the terrestrial geometric amplitude εgeo⊕ =6πCGMWTNp,⊕ ≃2.3×10−12,derived from the geometric projection of the Earth’s protonic wave field, distinct from the energetic projection that reconstructs the gravitational acceleration g. Applied to the Earth radius, this amplitude gives a micrometric contraction scale∆Lgeo⊕ ≃ 14.5µm,which lies in the same domain as the effective phase-distance gT2 measured in millisecond light-pulse atom interferometry.The article then organizes a sequence of experimental comparisons into three levels.First-level established cases include atom-interferometric phase shifts, dual-species tests, gravity gradiometry, source-mass measurements, the gravitational Aharonov–Bohm phase, atomic clocks, blackbody-radiation shifts, and residual caesium fountain shifts. In these cases, the terrestrial GMWT amplitude enters explicitly as a normalized geometric factor.Exploratory first-level cases are then considered separately: the Tajmar superconducting ring anomaly and LIGO blip glitches, where the same terrestrial amplitude appears in geometry-sensitive but unresolved phenomena. Finally, second-level wave-geometric cases, including Hong–Ou–Mandel interference, Haroche-type cavities, high-finesse optical cavities, optomechanics, circuit-QED, and cesium anomalous phases, are used to test the broader GMWT idea that waves carry both energetic and geometric components. The aim is not to claim experimental confirmation of GMWT, nor to treat all cases as having the same evidential status. Rather, the article proposes a structured experimental roadmap showing that a single normalized GMWT architecture yields recurrent order-of magnitude correspondences across matter-wave phase, frequency shifts, effective wave-space dilations, inertial anomalies, and interferometric transients.

•Jul 24, 2026•0 citations

Atom Interferometry with Bose-Einstein condensates to measure $\alpha$

Alan O. Jamison, Benjamin Plotkin-Swing, Anders H. Hansen +4 more

Bulletin of the American Physical Society•Jun 6, 2012•0 citations
Atom Interferometry: A Matter Wave Clock and a Measurement of α\alphaα
Optical clocks and atom interferometers provide complementary ways to measure time, motion and gravity. Combining these capabilities requires matter-wave beam splitters that manipulate different clock states in the same way, so that optical internal energy becomes a controlled degree of freedom rather than a source of systematic phase shifts. Here we realized a dual matter-wave interferometer operating simultaneously on the two states of the 88^{88}88Sr optical clock transition, 1S0^1S_01S0​ and 3P0^3P_03P0​. The interferometer is driven by Bragg pulses at the 813 nm magic wavelength, for which the two clock states experience the same optical coupling strength. This realizes a common matter-wave beam splitter for atoms whose internal energies differ by an optical excitation. With a sensitivity of 30 mrad, our measurement is consistent with a zero differential phase shift between the two clock-state Mach-Zehnder interferometers, translating to an absence of state-dependent acceleration in free fall at the level of 10−510^{-5}10−5. We further used the same interferometer to measure state-dependent optical dipole forces and determine a tune-out wavelength of the metastable 3P0^3P_03P0​ state to be 478.95(8) nm. These results establish magic-wavelength clock-state interferometry as a platform for differential force sensing, excited-state polarizability metrology and future quantum-clock tests of gravity.
The Sagnac effect enables interferometric measurements of rotation with high precision. Using matter waves instead of light promises resolution enhancement by orders of magnitude that scales with particle mass. So far, the paradigm for matter wave Sagnac interferometry relies on de Broglie waves and thus on free propagation of atoms either in free fall or within waveguides. However, the Sagnac effect can be expressed as a proper time difference experienced by two observers moving in opposite directions along closed paths and has indeed been measured with atomic clocks flown around Earth. Inspired by this, we investigate an interferometer comprised of a single atomic clock. The Sagnac effect manifests as a phase shift between trapped atoms in different internal states after transportation along closed paths in opposite directions, without any free propagation. With analytic models, we quantify limitations of the scheme arising from atomic dynamics and finite temperature. Furthermore, we suggest an implementation with previously demonstrated technology.
This article investigates atom interferometry, precision clocks, resonant cavities, and selected geometry-sensitive anomalies as experimental consistency tests for the Gravitation Matter–Wave Theory (GMWT). The central quantity is the terrestrial geometric amplitude εgeo⊕ =6πCGMWTNp,⊕ ≃2.3×10−12,derived from the geometric projection of the Earth’s protonic wave field, distinct from the energetic projection that reconstructs the gravitational acceleration g. Applied to the Earth radius, this amplitude gives a micrometric contraction scale∆Lgeo⊕ ≃ 14.5µm,which lies in the same domain as the effective phase-distance gT2 measured in millisecond light-pulse atom interferometry.The article then organizes a sequence of experimental comparisons into three levels.First-level established cases include atom-interferometric phase shifts, dual-species tests, gravity gradiometry, source-mass measurements, the gravitational Aharonov–Bohm phase, atomic clocks, blackbody-radiation shifts, and residual caesium fountain shifts. In these cases, the terrestrial GMWT amplitude enters explicitly as a normalized geometric factor.Exploratory first-level cases are then considered separately: the Tajmar superconducting ring anomaly and LIGO blip glitches, where the same terrestrial amplitude appears in geometry-sensitive but unresolved phenomena. Finally, second-level wave-geometric cases, including Hong–Ou–Mandel interference, Haroche-type cavities, high-finesse optical cavities, optomechanics, circuit-QED, and cesium anomalous phases, are used to test the broader GMWT idea that waves carry both energetic and geometric components. The aim is not to claim experimental confirmation of GMWT, nor to treat all cases as having the same evidential status. Rather, the article proposes a structured experimental roadmap showing that a single normalized GMWT architecture yields recurrent order-of magnitude correspondences across matter-wave phase, frequency shifts, effective wave-space dilations, inertial anomalies, and interferometric transients.
Atom Interferometry with Bose-Einstein condensates to measure α\alphaα