Superconducting Nonlinear Kinetic Inductance Devices

Kher, Aditya Shreyas

Published Feb 10, 2017• 19 citations
Publisher

Abstract

We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.

DOI
10.7907/z9jq0z1f

Related papers

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Paul Szypryt, D. A. Bennett, I. M. Fogarty Florang +12 more

Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of $$1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}$$ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

arXiv:2405.15017•Communications Engineering•Nov 6, 2024•19 citations

Development of an Array of Kinetic Inductance Magnetometers (KIMs)

Sasha Sypkens, Farzad Faramarzi, Marco Colangelo +6 more

We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).

arXiv:2102.11001•IEEE Transactions on Applied Superconductivity•Feb 3, 2021•3 citations

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Andrea Giachero, Michael R. Vissers, Jordan Wheeler +6 more

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

arXiv:2403.11354•Journal of Low Temperature Physics•Apr 5, 2024•16 citations

SKIFFS: Superconducting Kinetic Inductance Field-Frequency Sensors for sensitive magnetometry in moderate background magnetic fields

Abraham T. Asfaw, Ethan Kleinbaum, Thomas Hazard +3 more

We describe sensitive magnetometry using lumped-element resonators fabricated from a superconducting thin film of NbTiN. Taking advantage of the large kinetic inductance of the superconductor, we demonstrate a continuous resonance frequency shift of 27 MHz for a change in the magnetic field of 1.8 μT within a perpendicular background field of 60 mT. By using phase-sensitive readout of microwaves transmitted through the sensors, we measure phase shifts in real time with a sensitivity of 1°/nT. We present measurements of the noise spectral density of the sensors and find that their field sensitivity is at least within one to two orders of magnitude of superconducting quantum interference devices operating with zero background field. Our superconducting kinetic inductance field-frequency sensors enable real-time magnetometry in the presence of moderate perpendicular background fields up to at least 0.2 T. Applications for our sensors include the stabilization of magnetic fields in long coherence electron spin resonance measurements and quantum computation.

arXiv:1807.09860•Applied Physics Letters•Oct 22, 2018•5 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations

Hybridized-Mode Parametric Amplifier in Kinetic-Inductance Circuits

Danial Davoudi, Abdul Mohamed, Shabir Barzanjeh

Parametric amplification is essential for quantum measurement, enabling the amplification of weak microwave signals with minimal added noise. While Josephson-junction-based amplifiers have become standard in superconducting quantum circuits, their magnetic sensitivity, limited saturation power, and sub-kelvin operating requirements motivate the development of alternative nonlinear platforms. Here we demonstrate a two-mode kinetic-inductance parametric amplifier based on a pair of capacitively coupled Kerr-nonlinear resonators fabricated from NbTiN and NbN thin films. The distributed Kerr nonlinearity of these materials enables nondegenerate four-wave-mixing amplification with gains approaching 40 dB, gain-bandwidth products up to 6.9 MHz, and 1-dB compression powers two to three orders of magnitude higher than those of state-of-the-art Josephson amplifiers. A coupled-mode theoretical model accurately captures the pump-induced modification of the hybridized modes and quantitatively reproduces the observed signal and idler responses. The NbN device exhibits a significantly larger Kerr coefficient and superior gain-bandwidth performance, highlighting the advantages of high-kinetic-inductance materials. Our results establish coupled kinetic-inductance resonators as a robust platform for broadband, high-power, and magnetically resilient quantum-limited amplification, offering a scalable route for advanced readout in superconducting qubits, spin ensembles, quantum dots, and other microwave-quantum technologies.

quant-pharXiv:2512.03362•Dec 4, 2025•2 citations
We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.
Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/Hz1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}1.4pA/Hz​ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.
We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).
Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.
We describe sensitive magnetometry using lumped-element resonators fabricated from a superconducting thin film of NbTiN. Taking advantage of the large kinetic inductance of the superconductor, we demonstrate a continuous resonance frequency shift of 27 MHz for a change in the magnetic field of 1.8 μT within a perpendicular background field of 60 mT. By using phase-sensitive readout of microwaves transmitted through the sensors, we measure phase shifts in real time with a sensitivity of 1°/nT. We present measurements of the noise spectral density of the sensors and find that their field sensitivity is at least within one to two orders of magnitude of superconducting quantum interference devices operating with zero background field. Our superconducting kinetic inductance field-frequency sensors enable real-time magnetometry in the presence of moderate perpendicular background fields up to at least 0.2 T. Applications for our sensors include the stabilization of magnetic fields in long coherence electron spin resonance measurements and quantum computation.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
Parametric amplification is essential for quantum measurement, enabling the amplification of weak microwave signals with minimal added noise. While Josephson-junction-based amplifiers have become standard in superconducting quantum circuits, their magnetic sensitivity, limited saturation power, and sub-kelvin operating requirements motivate the development of alternative nonlinear platforms. Here we demonstrate a two-mode kinetic-inductance parametric amplifier based on a pair of capacitively coupled Kerr-nonlinear resonators fabricated from NbTiN and NbN thin films. The distributed Kerr nonlinearity of these materials enables nondegenerate four-wave-mixing amplification with gains approaching 40 dB, gain-bandwidth products up to 6.9 MHz, and 1-dB compression powers two to three orders of magnitude higher than those of state-of-the-art Josephson amplifiers. A coupled-mode theoretical model accurately captures the pump-induced modification of the hybridized modes and quantitatively reproduces the observed signal and idler responses. The NbN device exhibits a significantly larger Kerr coefficient and superior gain-bandwidth performance, highlighting the advantages of high-kinetic-inductance materials. Our results establish coupled kinetic-inductance resonators as a robust platform for broadband, high-power, and magnetically resilient quantum-limited amplification, offering a scalable route for advanced readout in superconducting qubits, spin ensembles, quantum dots, and other microwave-quantum technologies.