Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A large mode optical resonator for enhanced atom interferometry

Sapam Ranjita Chanu, N. Mielec, David Holleville, Bess Fang, Arnaud Landragin, Rémi Geiger, Isabelle Riou, B. Canuel

Published Jul 1, 2017• 0 citations
Publisher

Abstract

The development of atom interferometry in the last few decades has led to high precision measurements of inertial effects and tests of fundamental physics. New methods for higher sensitivity atom interferometers (AIs) are being explored, particularly the interrogation of atoms with optical cavities [1]. Its benefits would be higher optical power allowing large momentum transfer beam splitters, and possibly cleaner and controlled phase profiles. However high sensitivity AIs require long interrogation times, which combined with cold atom expansion, bring the challenges of large waists in cavities.

DOI
10.1109/fcs.2017.8088989

Related papers

A large mode optical resonator for enhanced atom interferometry

N. Mielec, Sapam Ranjita Chanu, Isabelle Riou +5 more

Summary form only given. The development of atom interferometry in the last few decades has led to high precision measurements of inertial effects and tests of fundamental physics [1]. New methods for higher sensitivity atom interferometers (AIs) are being explored, in particular the interrogation of atoms with optical cavities. The benefits of optical cavities would be higher optical power allowing large momentum transfer beam splitters, and possibly cleaner and controlled phase profiles [2]. However high sensitivity AIs require long interrogation times, which, combined with cold atom cloud expansion, bring the challenges of large centimetric waists in cavities. We propose an optical resonator composed of a convergent lens with two flat mirrors at its focal planes as shown on figure 1 [3]. When perfectly aligned any input field can be resonating inside. Especially, when a Gaussian beam, with waist w0' on the first mirror, is inputted to the cavity, the lens conjugates it to the second mirror with waist w0= λf/πw0'. This cavity is marginally stable and exhibits a half degenerate behaviour: all modes resonate at the same frequencies, odd and even modes being separated by half a free spectral range. Thus it does not have strong mode cleaning properties but it is able to magnify any input field. When misaligned, this cavity goes out of its degenerate behaviour and the circulating field begins to degrade due to mode filtering. A numerical study of the cavity behaviour, using an ABCD transfer matrix formalism, showed that typical controllable misalignments of a few micrometres would not be critical for atom interrogation. Further degradations due to surface defects and tilts are being investigated.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

High resolution atom interferometry with optical resonators

Isabelle Riou, G. Lefèvre, N. Mielec +7 more

During the past decades, atom interferometry experiments were developed for various applications like precision measurement of fundamental constants [1, 2], gravimetry [3], gradiometry [4] or inertial sensing [5, 6].

International Conference on Space Optics (ICSO)•Sep 25, 2017•0 citations

Multiphoton Atom Interferometry via Cavity-Enhanced Bragg Diffraction

Dylan O. Sabulsky, Joseph Junca, X. Zou +7 more

We present a novel atom interferometer configuration that combines large momentum transfer with the enhancement of an optical resonator for the purpose of measuring gravitational strain in the horizontal directions. Using Bragg diffraction and taking advantage of the optical gain provided by the resonator, we achieve momentum transfer up to 8ℏk with mW level optical power in a cm-sized resonating waist. Importantly, our experiment uses an original resonator design that allows for a large resonating beam waist and eliminates the need to trap atoms in cavity modes. We demonstrate inertial sensitivity in the horizontal direction by measuring the change in tilt of our resonator. This result paves the way for future hybrid atom or optical gravitational wave detectors. Furthermore, the versatility of our method extends to a wide range of measurement geometries and atomic sources, opening up new avenues for the realization of highly sensitive inertial atom sensors.

arXiv:2201.11693•Physical Review Letters•May 23, 2024•13 citations

Atom Interferometry in an Optical Cavity

Paul Hamilton, Matt Jaffe, Justin M. Brown +3 more

We propose and demonstrate a new scheme for atom interferometry, using light pulses inside an optical cavity as matter wave beam splitters. The cavity provides power enhancement, spatial filtering, and a precise beam geometry, enabling new techniques such as low power beam splitters (<100 μW), large momentum transfer beam splitters with modest power, or new self-aligned interferometer geometries utilizing the transverse modes of the optical cavity. As a first demonstration, we obtain Ramsey-Raman fringes with >75% contrast and measure the acceleration due to gravity, g, to 60 μg/sqrt[Hz] resolution in a Mach-Zehnder geometry. We use >10(7) cesium atoms in the compact mode volume (600 μm 1/e(2) waist) of the cavity and show trapping of atoms in higher transverse modes. This work paves the way toward compact, high sensitivity, multiaxis interferometry.

arXiv:1409.7130•Physical Review Letters•Mar 11, 2015•113 citations

Benefits and challenges of high sensitivity atom interferometers in optical cavities

N. Mielec, Isabelle Riou, Bess Fang +3 more

•Jan 1, 2016•0 citations

Interleaved atom interferometry for high-sensitivity inertial measurements

Denis Savoie, Matteo Altorio, Bess Fang +3 more

Interleaved atom interferometry brings high sensitivity and temporal resolution to cold-atom inertial sensors.

arXiv:1808.10801•Science Advances•Dec 7, 2018•231 citations
The development of atom interferometry in the last few decades has led to high precision measurements of inertial effects and tests of fundamental physics. New methods for higher sensitivity atom interferometers (AIs) are being explored, particularly the interrogation of atoms with optical cavities [1]. Its benefits would be higher optical power allowing large momentum transfer beam splitters, and possibly cleaner and controlled phase profiles. However high sensitivity AIs require long interrogation times, which combined with cold atom expansion, bring the challenges of large waists in cavities.
Summary form only given. The development of atom interferometry in the last few decades has led to high precision measurements of inertial effects and tests of fundamental physics [1]. New methods for higher sensitivity atom interferometers (AIs) are being explored, in particular the interrogation of atoms with optical cavities. The benefits of optical cavities would be higher optical power allowing large momentum transfer beam splitters, and possibly cleaner and controlled phase profiles [2]. However high sensitivity AIs require long interrogation times, which, combined with cold atom cloud expansion, bring the challenges of large centimetric waists in cavities. We propose an optical resonator composed of a convergent lens with two flat mirrors at its focal planes as shown on figure 1 [3]. When perfectly aligned any input field can be resonating inside. Especially, when a Gaussian beam, with waist w0' on the first mirror, is inputted to the cavity, the lens conjugates it to the second mirror with waist w0= λf/πw0'. This cavity is marginally stable and exhibits a half degenerate behaviour: all modes resonate at the same frequencies, odd and even modes being separated by half a free spectral range. Thus it does not have strong mode cleaning properties but it is able to magnify any input field. When misaligned, this cavity goes out of its degenerate behaviour and the circulating field begins to degrade due to mode filtering. A numerical study of the cavity behaviour, using an ABCD transfer matrix formalism, showed that typical controllable misalignments of a few micrometres would not be critical for atom interrogation. Further degradations due to surface defects and tilts are being investigated.
We present a novel atom interferometer configuration that combines large momentum transfer with the enhancement of an optical resonator for the purpose of measuring gravitational strain in the horizontal directions. Using Bragg diffraction and taking advantage of the optical gain provided by the resonator, we achieve momentum transfer up to 8ℏk with mW level optical power in a cm-sized resonating waist. Importantly, our experiment uses an original resonator design that allows for a large resonating beam waist and eliminates the need to trap atoms in cavity modes. We demonstrate inertial sensitivity in the horizontal direction by measuring the change in tilt of our resonator. This result paves the way for future hybrid atom or optical gravitational wave detectors. Furthermore, the versatility of our method extends to a wide range of measurement geometries and atomic sources, opening up new avenues for the realization of highly sensitive inertial atom sensors.
We propose and demonstrate a new scheme for atom interferometry, using light pulses inside an optical cavity as matter wave beam splitters. The cavity provides power enhancement, spatial filtering, and a precise beam geometry, enabling new techniques such as low power beam splitters (<100 μW), large momentum transfer beam splitters with modest power, or new self-aligned interferometer geometries utilizing the transverse modes of the optical cavity. As a first demonstration, we obtain Ramsey-Raman fringes with >75% contrast and measure the acceleration due to gravity, g, to 60 μg/sqrt[Hz] resolution in a Mach-Zehnder geometry. We use >10(7) cesium atoms in the compact mode volume (600 μm 1/e(2) waist) of the cavity and show trapping of atoms in higher transverse modes. This work paves the way toward compact, high sensitivity, multiaxis interferometry.