Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Spin-exchange collision cooling in an ultracold $^{85}$Rb/$^{87}$Rb Mixture

Mathew Hamilton, Rebekah Ferrier, Jacob Roberts

Published Jun 15, 2011• 0 citations
OpenAlex

Related papers

Spin Exchange Cooling in an Ultracold $^{85/87}$Rb Mixture

Rebekah Ferrier, Mathew Hamilton, Jacob Roberts

Bulletin of the American Physical Society•Jun 5, 2012•0 citations

Spin-exchange and spin-relaxation in ultracold Rb-Sr$^+$ collisions

Masato Morita, Tomáš Šikorský, Ziv Meir +6 more

Bulletin of the American Physical Society•May 30, 2018•0 citations

Observation of resonant dipole collisions in ultracold 23 Na 87 Rb rotational mixtures

J. He, Xin Ye, Junyu Lin +1 more

APS•May 1, 2019•0 citations

Three-body collision in ultracold Cs/Rb and Cs/Li mixtures

Paul S. Julienne, Yujun Wang

Bulletin of the American Physical Society•Jun 7, 2013•0 citations

Spin-Exchange Cross Section for Rb^ -Rb^ and Rb^ -Cs^ Collisions

H. M. Gibbs

Physical review. D/Physical review. D.•Jan 1, 1967•0 citations

Experimental realization of two-isotope collision-assisted Zeeman cooling

Mathew Hamilton, Roberts, Jacob, Lundeen, Stephen +2 more

The work presented in this thesis focuses on the demonstration and initial evaluation of a novel non-evaporative cooling method called collision-assisted Zeeman cooling. For this realization, an ultracold gas consisting of a mixture of 87Rb and 8Rb was used. Cooling was accomplished through interisotope inelastic spin-exchange collisions that converted kinetic energy into magnetic energy. Continual optical pumping spin polarized the 85Rb which ensured that only kinetic energy reducing collisions occurred and the scattered pump photons carried entropy out of the system. Thus, cooling of the ultracold gas can be achieved without requiring the loss of any atoms in order to do so. This represents a theoretical advantage over forced evaporative cooling, which is the current state-of-the-art cooling technique in most experiments. This thesis discusses the details of collision-assisted Zeeman cooling, as well as how the theory of the technique has been extended from cooling a single species to cooling with two species. There are many predicted advantages from using two rather than one species of atom in this type of cooling: greater flexibility in finding favorable spin-exchange collision rates, easier requirements on the magnetic fields that must be used, and an additional means to mitigate reabsorption (the primary limitation in many if not most non-evaporative cooling techniques). The experimental considerations needed to prepare a system that simultaneously trapped two isotopes to be able to perform collision-assisted Zeeman cooling are discussed. Because this cooling scheme is highly reliant on the initial conditions of the system, a focused experiment examining the loading of the optical trap with both isotopes of Rb was conducted and the results of that experiment are described here. The first experimental observations of spin-exchange collisions in an ultracold gas mixture of Rb are described as a part of this work. The experiments where collision-assisted Zeeman cooling were demonstrated are then described and evaluated. In this first implementation of the cooling technique the initial densities were too low and optical-pump-induced heating and loss too high for achieving the full predicted performance of the cooling technique. Through additional modeling, these limitations were understood and the necessary improvements for the next iteration of CAZ cooling experiments are laid out at the end of this work.

•Jan 3, 2007•0 citations
Spin-exchange collision cooling in an ultracold 85^{85}85Rb/87^{87}87Rb Mixture
Spin Exchange Cooling in an Ultracold 85/87^{85/87}85/87Rb Mixture
Spin-exchange and spin-relaxation in ultracold Rb-Sr+^++ collisions
The work presented in this thesis focuses on the demonstration and initial evaluation of a novel non-evaporative cooling method called collision-assisted Zeeman cooling. For this realization, an ultracold gas consisting of a mixture of 87Rb and 8Rb was used. Cooling was accomplished through interisotope inelastic spin-exchange collisions that converted kinetic energy into magnetic energy. Continual optical pumping spin polarized the 85Rb which ensured that only kinetic energy reducing collisions occurred and the scattered pump photons carried entropy out of the system. Thus, cooling of the ultracold gas can be achieved without requiring the loss of any atoms in order to do so. This represents a theoretical advantage over forced evaporative cooling, which is the current state-of-the-art cooling technique in most experiments. This thesis discusses the details of collision-assisted Zeeman cooling, as well as how the theory of the technique has been extended from cooling a single species to cooling with two species. There are many predicted advantages from using two rather than one species of atom in this type of cooling: greater flexibility in finding favorable spin-exchange collision rates, easier requirements on the magnetic fields that must be used, and an additional means to mitigate reabsorption (the primary limitation in many if not most non-evaporative cooling techniques). The experimental considerations needed to prepare a system that simultaneously trapped two isotopes to be able to perform collision-assisted Zeeman cooling are discussed. Because this cooling scheme is highly reliant on the initial conditions of the system, a focused experiment examining the loading of the optical trap with both isotopes of Rb was conducted and the results of that experiment are described here. The first experimental observations of spin-exchange collisions in an ultracold gas mixture of Rb are described as a part of this work. The experiments where collision-assisted Zeeman cooling were demonstrated are then described and evaluated. In this first implementation of the cooling technique the initial densities were too low and optical-pump-induced heating and loss too high for achieving the full predicted performance of the cooling technique. Through additional modeling, these limitations were understood and the necessary improvements for the next iteration of CAZ cooling experiments are laid out at the end of this work.