Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Results from the Cold Atom Laboratory's ground test bed

Ethan Elliott

Published Jun 8, 2017• 0 citations
OpenAlex

Related papers

NASA's Cold Atom Laboratory (CAL): system integration and ground tests

David C. Aveline, Ethan Elliott, Jason Williams +1 more

Bulletin of the American Physical Society•May 30, 2018•1 citation

Experiments with Cold Atoms

Jean Dalibard, Christophe Salomon

Birkhäuser Basel eBooks•Jan 1, 2004•1 citation

Comparison of laser system designs for quantum technologies: BECCAL flight system vs. BECCAL ground test bed

Victoria Henderson, Jean Pierre Marburger, André Wenzlawski +31 more

Abstract We present the design of laser systems for the Bose-Einstein Condensate and Cold Atom Laboratory (BECCAL) payload, enabling numerous quantum technological experiments onboard the International Space Station (ISS), in particular dual species 87 Rb and 41 K Bose-Einstein condensates. A flight model (FM) and a commercial off the shelf (COTS) based model are shown, both of which meet the BECCAL requirements in terms of functionality, but have differing size, weight and power (SWaP) and environmental requirements. The capabilities of both models are discussed and characteristics compared. The flight model of BECCAL uses specifically developed and qualified custom components to create a compact and robust system suitable for long-term remote operation onboard the ISS. This system is based on ECDL-MOPA lasers and free-space optical benches made of Zerodur, as well as commercial fibre components. The COTS-based system utilizes entirely commercial parts to create a functionally equivalent system for operation in a standard laboratory, without the strict SWaP and environmental constraints of the flight model.

arXiv:2505.08680•EPJ Quantum Technology•Nov 26, 2025•0 citations

SOME PROBLEMS IN COLD ATOM RESEARCH

C. N. Yang

WORLD SCIENTIFIC eBooks•Jan 1, 2026•0 citations

SOME PROBLEMS IN COLD ATOM RESEARCH

Chongming Yang

International Journal of Modern Physics B•Jul 20, 2010•1 citation

The space cold atom interferometer for testing the equivalence principle in the China Space Station

Meng He, Xi Chen, Jie Fang +25 more

The precision of the weak equivalence principle (WEP) test using atom interferometers (AIs) is expected to be extremely high in microgravity environment. The microgravity scientific laboratory cabinet (MSLC) in the China Space Station (CSS) can provide a higher-level microgravity than the CSS itself, which provides a good experimental environment for scientific experiments that require high microgravity. We designed and realized a payload of a dual-species cold rubidium atom interferometer. The payload is highly integrated and has a size of [Formula: see text]. It will be installed in the MSLC to carry out high-precision WEP test experiment. In this article, we introduce the constraints and guidelines of the payload design, the compositions and functions of the scientific payload, the expected test precision in space, and some results of the ground test experiments.

arXiv:2306.04097•npj Microgravity•Jul 28, 2023•29 citations
Abstract We present the design of laser systems for the Bose-Einstein Condensate and Cold Atom Laboratory (BECCAL) payload, enabling numerous quantum technological experiments onboard the International Space Station (ISS), in particular dual species 87 Rb and 41 K Bose-Einstein condensates. A flight model (FM) and a commercial off the shelf (COTS) based model are shown, both of which meet the BECCAL requirements in terms of functionality, but have differing size, weight and power (SWaP) and environmental requirements. The capabilities of both models are discussed and characteristics compared. The flight model of BECCAL uses specifically developed and qualified custom components to create a compact and robust system suitable for long-term remote operation onboard the ISS. This system is based on ECDL-MOPA lasers and free-space optical benches made of Zerodur, as well as commercial fibre components. The COTS-based system utilizes entirely commercial parts to create a functionally equivalent system for operation in a standard laboratory, without the strict SWaP and environmental constraints of the flight model.
The precision of the weak equivalence principle (WEP) test using atom interferometers (AIs) is expected to be extremely high in microgravity environment. The microgravity scientific laboratory cabinet (MSLC) in the China Space Station (CSS) can provide a higher-level microgravity than the CSS itself, which provides a good experimental environment for scientific experiments that require high microgravity. We designed and realized a payload of a dual-species cold rubidium atom interferometer. The payload is highly integrated and has a size of [Formula: see text]. It will be installed in the MSLC to carry out high-precision WEP test experiment. In this article, we introduce the constraints and guidelines of the payload design, the compositions and functions of the scientific payload, the expected test precision in space, and some results of the ground test experiments.