Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Information and Measurement (QIM)

Controlling Induced Coherence in Parametric Down-Conversion

Mikhail I. Kolobov, Enno Giese, Samuel Lemieux, Robert Fickler, Robert W. Boyd

Published Jan 1, 2017• 0 citations
Publisher

Abstract

We address the question of controlling induced coherence between two coherently pumped parametric down-convertors. We evaluate visibility in the interference pattern of two signal waves and demonstrate that for high parametric gain it can approach values arbitrarily close to unity.
DOI
10.1364/qim.2017.qf5c.1

Related papers

Coherence in two-photon down-conversion induced by a laser

Z. Y. Ou, L. J. Wang, X. Y. Zou +1 more

We discuss the situation in which idler beams from two parametric down-converter crystals are allowed to interfere. We show that, when two mutually coherent signal beams derived from a common laser are injected into the down-converters, the two idler beams can become mutually coherent also. Moreover, the resulting interference pattern can, in principle, have 100% visibility when the number of injected photons per unit down-converter bandwidth is large. This is just the condition for stimulated down-conversion to dominate over spontaneous down-conversion.

Physical Review A•Feb 1, 1990•53 citations

Coherence in two-photon down-conversion induced by a laser

L. J. Wang, X. Y. Zou, L. Mandeļ

Normally, the signal and idler photons produced in the process of parametric down- conversion exhibit no second-order interference. However, in the presence of an external laser beam that follows the path of the signal photon and induces stimulated down-conversions, one would expect coherence to develop between the down-converted signal and idler beams. We have demonstrated the existence of this phenomenon in an experiment with two down-converters pumped by similar pump beams, in which two mutually coherent laser beams followed the paths of the two down-converted signal photons and induced coherence between the two down- converted idler beams. The induced coherence gives rise to observable interference effects, which are presented.

Annual Meeting Optical Society of America•Jan 1, 1990•2 citations

The evidence of phase memory in induced coherence without induced emission

Axel Heuer, Sarah Fritsch, Ralf Menzel

Two signal beams emitted from two simultaneously pumped parametric down converters show first order interference if the two idler beams were aligned. Due to the effect of phase memory it is found that the first order interference of the signal beams can be controlled by the phase delay between the pump beams.

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Induced coherence without induced emission resulting in nonlocal interference

X. Y. Zou, L. J. Wang, L. Mandeļ

Although induced coherence is generally associated with induced or stimulated emission, in the process of spontaneous parametric downconversion of light induced coherence can be generated on its own. This is demonstrated in an experiment in which the signal beams from two coherently pumped downconverters come together and interfere whenever the idler beam from the first downconverter (DC1) passes through and is aligned with the second downconverter (DC2). Misaligning the idlers, or blocking the first idler, makes the interference disappear. More generally, the degree of coherence can be controlled by varying the amplitude of the idler from DC1 that reaches DC2. The interpretation of this nonclassical interference is discussed in terms of the interpretation of the wave function or state vector of the emitted photon.

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations

The Role of Pump Coherence in a Two-photon Interference Experiment

Junlin Liang, S. M. Hendrickson, T. B. Pittman

We perform a parametric down-conversion two-photon interference experiment using two unbalanced Mach-Zehnder interferometers and a short-coherence-length continuous-wave pump. The experiment explores the role of the pump coherence in two-photon interferometry.

Frontiers in Optics•Jan 1, 2010•0 citations

Quantum interferometry using coherent beam stimulated parametric down-conversion

Aziz Kolkıran, G. S. Agarwal

We show how stimulated parametric processes can be employed in experiments on beyond the diffraction limit to overcome the problem of low visibility obtained by using spontaneous down conversion operating in the high gain regime. We further show enhancement of the count rate by several orders when stimulated parametric processes are used. Both the two photon counts and the visibility can be controlled by the phase of the stimulating coherent beam.

arXiv:0805.0604•Optics Express•Apr 23, 2008•22 citations
We discuss the situation in which idler beams from two parametric down-converter crystals are allowed to interfere. We show that, when two mutually coherent signal beams derived from a common laser are injected into the down-converters, the two idler beams can become mutually coherent also. Moreover, the resulting interference pattern can, in principle, have 100% visibility when the number of injected photons per unit down-converter bandwidth is large. This is just the condition for stimulated down-conversion to dominate over spontaneous down-conversion.
Normally, the signal and idler photons produced in the process of parametric down- conversion exhibit no second-order interference. However, in the presence of an external laser beam that follows the path of the signal photon and induces stimulated down-conversions, one would expect coherence to develop between the down-converted signal and idler beams. We have demonstrated the existence of this phenomenon in an experiment with two down-converters pumped by similar pump beams, in which two mutually coherent laser beams followed the paths of the two down-converted signal photons and induced coherence between the two down- converted idler beams. The induced coherence gives rise to observable interference effects, which are presented.
Although induced coherence is generally associated with induced or stimulated emission, in the process of spontaneous parametric downconversion of light induced coherence can be generated on its own. This is demonstrated in an experiment in which the signal beams from two coherently pumped downconverters come together and interfere whenever the idler beam from the first downconverter (DC1) passes through and is aligned with the second downconverter (DC2). Misaligning the idlers, or blocking the first idler, makes the interference disappear. More generally, the degree of coherence can be controlled by varying the amplitude of the idler from DC1 that reaches DC2. The interpretation of this nonclassical interference is discussed in terms of the interpretation of the wave function or state vector of the emitted photon.