The Effect of Dynamics of Moving Platforms on the Stability of High Performance Atomic Clocks

Andrey B. Matsko, Lute Maleki

Published Dec 4, 2014• 0 citations
OpenAlex

Abstract

The goal of present contribution is to attract attention of the community to the outstanding issues related to development of ultrastable and precise atomic clocks suitable for small moving platforms. We discuss importance of acceleration and vibration sensitivity of high stability atomic clocks based on optical transitions in atoms and study the response of elements commonly used in clocks in dynamic environments. It is shown that vibration sensitivity of alignment of optical train of either an optical trap or an ion trap results in heating of the atomic/ion cloud and in subsequent trap destabilization. It is also found that vibration sensitivity of the frequency of the lasers used for cooling, trapping, and interrogating the atoms can result in degradation of acceleration sensitivity of the clock as a whole.

Related papers

Optical atomic clocks and the quest for ultrastable lasers

F. Riehle

Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.

Frontiers in Optics•Jan 1, 2013•1 citation

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•47 citations

Chapter 10: Optical Atomic Clocks in Ion Traps

Helen S. Margolis

Narrow optical transitions in single laser-cooled trapped ions are highly reproducible in frequency and therefore make ideal references for accurate atomic clocks. This chapter provides an introduction to trapped ion optical clocks, covering their principles of operation and describing the different systems being studied at present. The performance of state-of-the-art trapped ion optical clocks is discussed and the various contributions to their frequency uncertainty budgets are outlined. Finally the further developments likely to occur over the next few years are considered.

IMPERIAL COLLEGE PRESS eBooks•Feb 11, 2014•0 citations

An ion trap design for a space-deployable strontium-ion optical clock

Alessio Spampinato, Jonathan Stacey, Sean Mulholland +5 more

Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88 Sr + optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10 18 with this system. We then explain the results of finite-element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trapping efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.

arXiv:2401.12706•Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences•Feb 1, 2024•8 citations

Optical atomic phase reference and timing

Leo W. Hollberg, E H Cornell, A Abdelrahmann

Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space–time science. Those systems require strain measurements at less than or equal to 10 −20 . As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, Δ Φ / Φ total ≤ 10 −20 , that could make an important impact in gravity wave science. This article is part of the themed issue ‘Quantum technology for the 21st century’.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Jun 26, 2017•7 citations

Extending the fundamental limit of atomic clock stability

Ravid Shaniv, Ayush Agrawal, David B. Hume

Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to $\approx 4.5 \text{ dB}$ compared with the two-level model. Furthermore, we identify an even greater stability enhancement of $\approx 5.4 \text{ dB}$ for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an $^{27}\text{Al}^{+}$ optical ion clock.

physics.atom-phCross-listedarXiv:2604.01099•Apr 2, 2026•0 citations
The goal of present contribution is to attract attention of the community to the outstanding issues related to development of ultrastable and precise atomic clocks suitable for small moving platforms. We discuss importance of acceleration and vibration sensitivity of high stability atomic clocks based on optical transitions in atoms and study the response of elements commonly used in clocks in dynamic environments. It is shown that vibration sensitivity of alignment of optical train of either an optical trap or an ion trap results in heating of the atomic/ion cloud and in subsequent trap destabilization. It is also found that vibration sensitivity of the frequency of the lasers used for cooling, trapping, and interrogating the atoms can result in degradation of acceleration sensitivity of the clock as a whole.
Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Narrow optical transitions in single laser-cooled trapped ions are highly reproducible in frequency and therefore make ideal references for accurate atomic clocks. This chapter provides an introduction to trapped ion optical clocks, covering their principles of operation and describing the different systems being studied at present. The performance of state-of-the-art trapped ion optical clocks is discussed and the various contributions to their frequency uncertainty budgets are outlined. Finally the further developments likely to occur over the next few years are considered.
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88 Sr + optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10 18 with this system. We then explain the results of finite-element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trapping efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.
Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space–time science. Those systems require strain measurements at less than or equal to 10 −20 . As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, Δ Φ / Φ total ≤ 10 −20 , that could make an important impact in gravity wave science. This article is part of the themed issue ‘Quantum technology for the 21st century’.
Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to ≈4.5 dB\approx 4.5 \text{ dB}≈4.5 dB compared with the two-level model. Furthermore, we identify an even greater stability enhancement of ≈5.4 dB\approx 5.4 \text{ dB}≈5.4 dB for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an 27Al+^{27}\text{Al}^{+}27Al+ optical ion clock.