Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

ACTA PHOTONICA SINICA

Experimental Research on Single-photon Detector Calibration and Comparison for the Collinear and Nonlinear Phase Matching Modes

郭园园 GUO Yuan-yuan, 高冬阳 GAO Dong-yang, 胡友勃 HU You-bo, 李健军 Li Jianjun, 郑小兵 Zheng Xiaobing, 闫静 YAN Jing

Published Jan 1, 2017• 0 citations
Publisher
DOI
10.3788/gzxb20174602.0223001

Related papers

Single-Photon Detector Calibration

Sergey V. Polyakov

Experimental methods in the physical sciences•Jan 1, 2013•6 citations

[Research on the Distribution of Broad-Band Correlated Photon Spectra and the Measurement of Time-Correlation].

Dongyang Gao, Jianjun Li, Mao-peng Xiao +1 more

The correlated photon technique makes it possible to achieve a radiation calibration processing without chain transferring. The study of the spectral radiation character and time correlation of the photon is of great significance for broad-band radiometric calibration. To absolutely calibrate quantum efficiency of photoelectric detector, it is necessary to extend calibration band from single band to more bands. According to the phase-matching condition of the spontaneous parametric down-conversion, non-collinear angle formula of correlated photon in the crystal is derived. The distribution of the photon spectrum is simulated. Meanwhile, the phase-matching angle of the crystal is optimized. The photon generated by the spontaneous parameters down-conversion has a broad spectral distribution and the correlated photon wavelength is corresponding to its emission angle. Based on the result of the simulation, the experimental measurement system of the spectral distribution and time-correlation of the correlated photon is established. The spectral distribution, the time-correlation and the polarization properties of the four pair photon were measured by using this system. The experimental results show that, (1) the spectral distribution of the measurements is 633~808 nm, where the maximum spectral distribution measurement bias is 1.51 mm. The experiment result is highly consistent with theoretical ones; (2) the correlation time of four pairs correlated photon is measured, during which “three coincidence-peaks” is observed and the minimum correlation time was 0.32 ns; (3) single photon count rate along with coincidence count rate of correlated photon vary with the polarization direction of the pump as sine function. The experimental result is shown that the correlated photon pairs are ranging from the visible to near infrared band distribution, and that the spectrum has time-correlation and polarization characteristic. The research result is firstly reported at home and abroad, and the results are promising for the application of the photoelectric detector in the multi-band radiometric calibration.

•May 1, 2016•0 citations

Analysis of the Spatial Properties of Correlated Photon in Collinear Phase-Matching

Lin Yin, Jianjun Li, Wenchao Zhai +3 more

In this paper, the spatial properties of correlated photon in collinear phase-matching in the process of spontaneous parametric down conversion (SPDC) are researched. Based on the study of the phase-matching angle, non-collinear angle, and correlated photon wavelength, a theoretical model of non-collinear angular variation is derived, which can be used to estimate and predict the width of the correlated photon ring. The experimental measurement is carried out with CMOS camera, and the measurement results are consistent with the theoretical simulation results, which verifies the rationality of theoretical reasoning. Meanwhile, the change of the correlated photon divergence angle outside the crystal is studied, the closer the wavelength is to the degenerate, the smaller the measurement value of the divergence angle, which is agreement with the theoretical simulation. The results of the study play a reference role in the evaluation of the spatial properties of correlated photon and lay a foundation for the measurement of the correlated photon number rate and the calibration of a photodetector.

Photonics•Jan 7, 2021•5 citations

Single-photon detection and its applications

Yan Liang, Heping Zeng

Science China Physics Mechanics and Astronomy•Apr 15, 2014•38 citations

Nonlinear optics for ultrafast single-photon detection

Mario Agio, Duncan G. England, Assegid M. Flatae +2 more

Elsevier eBooks•Jan 1, 2023•3 citations

Tailoring the down conversion emission profile via direct imaging with a camera

Hashir Kuniyil, Safak Ozcimen, Kadir Durak

We present the analysis of emission profile of downconverted photons from a critically phase-matched nonlinear crystal. This is done via direct imaging of down converted photons by a CMOS camera. The effects of nonlinear crystal thickness in collinear and non-collinear geometries on the down converted photon pair rate is directly observed and the experimental results show that the photon pair rate increases linearly with the crystal thickness. However, the rate of the photon pairs collected to a single mode fiber goes quadratically with the crystal length because of the cylindrical asymmetries in the optical path and the exit angle around the pump mode within the nonlinear crystal. The use of cameras for real-time and direct imaging of down conversion emission profile significantly simplifies the phase-matching alignments and the collecting the entangled photons.

arXiv:1909.04921•Sep 11, 2019•1 citation
The correlated photon technique makes it possible to achieve a radiation calibration processing without chain transferring. The study of the spectral radiation character and time correlation of the photon is of great significance for broad-band radiometric calibration. To absolutely calibrate quantum efficiency of photoelectric detector, it is necessary to extend calibration band from single band to more bands. According to the phase-matching condition of the spontaneous parametric down-conversion, non-collinear angle formula of correlated photon in the crystal is derived. The distribution of the photon spectrum is simulated. Meanwhile, the phase-matching angle of the crystal is optimized. The photon generated by the spontaneous parameters down-conversion has a broad spectral distribution and the correlated photon wavelength is corresponding to its emission angle. Based on the result of the simulation, the experimental measurement system of the spectral distribution and time-correlation of the correlated photon is established. The spectral distribution, the time-correlation and the polarization properties of the four pair photon were measured by using this system. The experimental results show that, (1) the spectral distribution of the measurements is 633~808 nm, where the maximum spectral distribution measurement bias is 1.51 mm. The experiment result is highly consistent with theoretical ones; (2) the correlation time of four pairs correlated photon is measured, during which “three coincidence-peaks” is observed and the minimum correlation time was 0.32 ns; (3) single photon count rate along with coincidence count rate of correlated photon vary with the polarization direction of the pump as sine function. The experimental result is shown that the correlated photon pairs are ranging from the visible to near infrared band distribution, and that the spectrum has time-correlation and polarization characteristic. The research result is firstly reported at home and abroad, and the results are promising for the application of the photoelectric detector in the multi-band radiometric calibration.
In this paper, the spatial properties of correlated photon in collinear phase-matching in the process of spontaneous parametric down conversion (SPDC) are researched. Based on the study of the phase-matching angle, non-collinear angle, and correlated photon wavelength, a theoretical model of non-collinear angular variation is derived, which can be used to estimate and predict the width of the correlated photon ring. The experimental measurement is carried out with CMOS camera, and the measurement results are consistent with the theoretical simulation results, which verifies the rationality of theoretical reasoning. Meanwhile, the change of the correlated photon divergence angle outside the crystal is studied, the closer the wavelength is to the degenerate, the smaller the measurement value of the divergence angle, which is agreement with the theoretical simulation. The results of the study play a reference role in the evaluation of the spatial properties of correlated photon and lay a foundation for the measurement of the correlated photon number rate and the calibration of a photodetector.
We present the analysis of emission profile of downconverted photons from a critically phase-matched nonlinear crystal. This is done via direct imaging of down converted photons by a CMOS camera. The effects of nonlinear crystal thickness in collinear and non-collinear geometries on the down converted photon pair rate is directly observed and the experimental results show that the photon pair rate increases linearly with the crystal thickness. However, the rate of the photon pairs collected to a single mode fiber goes quadratically with the crystal length because of the cylindrical asymmetries in the optical path and the exit angle around the pump mode within the nonlinear crystal. The use of cameras for real-time and direct imaging of down conversion emission profile significantly simplifies the phase-matching alignments and the collecting the entangled photons.