Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Effect of Aperture shape on Visibility of Quantum Cryptography System

Adawiya J. Haider, Azhar I. Hassan, Ali J. Addie

Published Mar 1, 2008• 0 citations
OpenAlex

Abstract

The main goal in Quantum Cryptography is high security and this can be achieved by using single photon sources, thus we have studied the entangled photon source and how the coincident count rate and visibility could be affected by the optical elements of the system setup. The present work is a theoretical analysis devoted to investigate the interference pattern of biphoton amplitude generated by spontaneous parametric down conversion (SPDC) in a nonlinear crystal (BBO) pumped by femto-second optical pulses. We have studied the visibility as a function of optical path delay for different parameters, such as the crystal length, aperture diameter, size and shape of the aperture The shape of interference pattern can be enhanced by using different shapes & sizes of aperture. So in the case of continuous wave ( CW )pumping, when using circular aperture the visibility is highest and symmetry shape occurs at lower aperture diameter (b=0.5mm). Asymmetry and wide dip pattern is occurred at larger aperture diameter (b=10mm), when using shifting ring, a negative peak was appeared. In case of pulsed pump asymmetry, patterns occur and increase with increase of crystal length and decreasing aperture diameter. When using slit aperture (vertical and horizontal direction), the coincident count is more symmetric in horizontal with dimension (1x7) mm. All the results of this work are based on several numerical techniques and different programming codes. For example, adaptive Simpson quadrator method have been used to numerically evaluate the double integral in some equations. And adaptive Lobatto quadrator method has been used to numerically evaluate a single integrals. The later method is more efficient when required a high accuracy or a smooth integral

Related papers

Effect of Gaussian Aperture Width on Visibility for Different Crystal Length

Adawiya J. Haider, Muslm Fadhel J

The main goal in Quantum Cryptography is high security and this can be achieved by using single photon sources. The present work is a theoretical analysis devoted to investigate the interference pattern of biphoton amplitude generated by spontaneous parametric down conversion (SPDC) in a nonlinear crystal (BBO) pumped by femtosecond optical pulses. We have studied the visibility as a function of Gaussion aperture width for different parameters, such as the crystal length. The best visibility can be obtained at crystal length of (1.5 mm) . In our results, patterns occur and increase with increase of crystal length and decreasing aperture diameter. When using slit aperture (vertical and horizontal direction), the coincident count is more symmetry in horizontal with dimension (1×7) mm. With double crystal and parallel direction,the visibility decreases dramatically with increase in the Gaussian aperture width, while at a distance between crystals equal to (3mm) the visibility vanishes slowly at crystal thickness (L=0.5mm).

Journal of Al-Nahrain University-Science•Jun 1, 2011•0 citations

Second Order Dispersion In The Interferometer's Optical Elements For Quantum Cryptography (QC) System

Adawiya J. Haider, Ali Q. Abdulfattah, Ahlam L. huraiji +1 more

In this study, we have studied the entangled photon source and how the coincidentcount rate and visibility could be affected by the optical elements of the system setup. Theprofile of the interference dip of the optical elements for Quantum Cryptography (QC)system is modified by the increase of the second order dispersion parameter (Dp) and lead toincrease of visibility. Non zero chirp parameter (ai) of the pump beam can provide a highercentral peak but on the other hand it reduces the visibility, the peak remains, while thedispersion in an optical element through which down converted photon propagate leads toasymmetry in the interference pattern dip , the dip is particularly stretched with larger valueof birefringent material length (20-30)mm. The highest visibility at birefringent materialdispersion (d) equals to zero, and the dip was broader at larger value of (d).

Engineering and Technology Journal•Mar 1, 2009•2 citations

Quantum interference with femtosecond entangled two-photon fields

Jan Peřina, Alexander V. Sergienko, Bahaa E. A. Saleh +1 more

We investigate quantum interference effects of entangled two-photon states generated in a nonlinear crystal pumped by femtosecond pulses. Attention is devoted to the effects of the pump-pulse profile (pulse duration and chirp) as well as those originating in second-order dispersion, both in the nonlinear crystal and in the optical elements through which the down-converted photons propagate. The characteristics of the pump pulse, along with the dispersion, influence on the visibility and the symmetry of the coincidence-count interference pattern. Nonlocal dispersion cancellation occurs in some cases.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 14, 1999•0 citations

Spectral Characterisation of Spontaneous Parametric-Down Conversion Entangled Photons Source in Femtosecond Pulsed Regime

G. Brida, Valentina Caricato, Marco Genovese +4 more

We report on experimental measurements of coincidence and single particle spectral shapes of biphoton signals when frequency entangled states are generated by SPDC crystals pumped by short pulses.It is shown evidence for biphoton coincidence spectrum narrower and single-particle one wider than the pump spectrum, with a large contrast between coincidence and singles distributions.The investigation of biphoton correlations has been performed by fixing one monochromator at the maximal transmission wavelength on down-converted signal gate and scanning the one placed in the idler branch in order to observe the spectral distribution of single counts and coincidences.The degree of entanglement is evaluated by the ratio of the FWHM of single particle and coincidence distributions: the greater the ratio, the greater is the entanglement.The degree of entanglement in frequency variables can be very high: it increases linearly with the length of the crystal, and decreases with the growing pump pulse.

International Conference on Quantum, Nano and Micro Technologies (ICQNM)•Feb 1, 2009•0 citations

Quantum interference by two temporally distinguishable pulses

Y.-H. Kim, Maria V. Chekhova, S. P. Kulik +1 more

We have experimentally demonstrated two-photon interference between biphoton amplitudes arising from two well-separated pump pulses. It is important to note the following. 1) The pump pulse intensity was low enough so that single counting rates of the detectors were kept much smaller than pulse repetition rates: the probability of having one spontaneous parametric down conversion (SPDC) photon pair per pulse in our experiment is negligible. Hence the interference cannot be explained as two SPDC photons from two pump pulses (one SPDC photon pair from each pulse) interfering at the detectors. The two pump pulses simply provide two biphoton amplitudes which could result in coincidence counts, and interference occurs between these two biphoton amplitudes only when they are indistinguishable. 2) The BBO crystal in our experiment was only 100 /spl mu/m thick, so the two-pulse did not exist in BBO at the same time at any moment. 3) Due to the delays in the interferometer (/spl tau/ /spl tau//sub 1/), the signal-idler never met at the beamsplitter. Therefore, the existence of two-photon interference cannot be viewed as the interference between the signal and idler photons. These three points again emphasize the fact that it is the indistinguishability of the two-photon Feynman alternatives for the biphoton amplitudes which is responsible for the two-photon quantum interference effects.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 20, 2003•0 citations

Characterization of Entanglement Photons Generated by a Spontaneous Parametric Down-Conversion Pulse Source

Ekkasit Sakatok, Surasak Chiangga

Quantum computation and quantum communication require sources of entangled photons, especially from low-cost diode lasers. This study considered a polarization entangled photons pulse source produced via a spontaneous parametric down-conversion process in the type-I phase-matching of two nonlinear crystals, incorporating a continuous wave laser diode operating in pulse mode as a pump. The generated photons were measured based on visibility as a function of the pump frequency and collection apertures. A polarization correlation between photon pairs of approximately 93% and a Bell parameter S value of 2.56 ± 0.05 were obtained using the source described here.

Agriculture and Natural Resources•Feb 28, 2011•0 citations
The main goal in Quantum Cryptography is high security and this can be achieved by using single photon sources, thus we have studied the entangled photon source and how the coincident count rate and visibility could be affected by the optical elements of the system setup. The present work is a theoretical analysis devoted to investigate the interference pattern of biphoton amplitude generated by spontaneous parametric down conversion (SPDC) in a nonlinear crystal (BBO) pumped by femto-second optical pulses. We have studied the visibility as a function of optical path delay for different parameters, such as the crystal length, aperture diameter, size and shape of the aperture The shape of interference pattern can be enhanced by using different shapes & sizes of aperture. So in the case of continuous wave ( CW )pumping, when using circular aperture the visibility is highest and symmetry shape occurs at lower aperture diameter (b=0.5mm). Asymmetry and wide dip pattern is occurred at larger aperture diameter (b=10mm), when using shifting ring, a negative peak was appeared. In case of pulsed pump asymmetry, patterns occur and increase with increase of crystal length and decreasing aperture diameter. When using slit aperture (vertical and horizontal direction), the coincident count is more symmetric in horizontal with dimension (1x7) mm. All the results of this work are based on several numerical techniques and different programming codes. For example, adaptive Simpson quadrator method have been used to numerically evaluate the double integral in some equations. And adaptive Lobatto quadrator method has been used to numerically evaluate a single integrals. The later method is more efficient when required a high accuracy or a smooth integral
The main goal in Quantum Cryptography is high security and this can be achieved by using single photon sources. The present work is a theoretical analysis devoted to investigate the interference pattern of biphoton amplitude generated by spontaneous parametric down conversion (SPDC) in a nonlinear crystal (BBO) pumped by femtosecond optical pulses. We have studied the visibility as a function of Gaussion aperture width for different parameters, such as the crystal length. The best visibility can be obtained at crystal length of (1.5 mm) . In our results, patterns occur and increase with increase of crystal length and decreasing aperture diameter. When using slit aperture (vertical and horizontal direction), the coincident count is more symmetry in horizontal with dimension (1×7) mm. With double crystal and parallel direction,the visibility decreases dramatically with increase in the Gaussian aperture width, while at a distance between crystals equal to (3mm) the visibility vanishes slowly at crystal thickness (L=0.5mm).
In this study, we have studied the entangled photon source and how the coincidentcount rate and visibility could be affected by the optical elements of the system setup. Theprofile of the interference dip of the optical elements for Quantum Cryptography (QC)system is modified by the increase of the second order dispersion parameter (Dp) and lead toincrease of visibility. Non zero chirp parameter (ai) of the pump beam can provide a highercentral peak but on the other hand it reduces the visibility, the peak remains, while thedispersion in an optical element through which down converted photon propagate leads toasymmetry in the interference pattern dip , the dip is particularly stretched with larger valueof birefringent material length (20-30)mm. The highest visibility at birefringent materialdispersion (d) equals to zero, and the dip was broader at larger value of (d).
We investigate quantum interference effects of entangled two-photon states generated in a nonlinear crystal pumped by femtosecond pulses. Attention is devoted to the effects of the pump-pulse profile (pulse duration and chirp) as well as those originating in second-order dispersion, both in the nonlinear crystal and in the optical elements through which the down-converted photons propagate. The characteristics of the pump pulse, along with the dispersion, influence on the visibility and the symmetry of the coincidence-count interference pattern. Nonlocal dispersion cancellation occurs in some cases.
We report on experimental measurements of coincidence and single particle spectral shapes of biphoton signals when frequency entangled states are generated by SPDC crystals pumped by short pulses.It is shown evidence for biphoton coincidence spectrum narrower and single-particle one wider than the pump spectrum, with a large contrast between coincidence and singles distributions.The investigation of biphoton correlations has been performed by fixing one monochromator at the maximal transmission wavelength on down-converted signal gate and scanning the one placed in the idler branch in order to observe the spectral distribution of single counts and coincidences.The degree of entanglement is evaluated by the ratio of the FWHM of single particle and coincidence distributions: the greater the ratio, the greater is the entanglement.The degree of entanglement in frequency variables can be very high: it increases linearly with the length of the crystal, and decreases with the growing pump pulse.
We have experimentally demonstrated two-photon interference between biphoton amplitudes arising from two well-separated pump pulses. It is important to note the following. 1) The pump pulse intensity was low enough so that single counting rates of the detectors were kept much smaller than pulse repetition rates: the probability of having one spontaneous parametric down conversion (SPDC) photon pair per pulse in our experiment is negligible. Hence the interference cannot be explained as two SPDC photons from two pump pulses (one SPDC photon pair from each pulse) interfering at the detectors. The two pump pulses simply provide two biphoton amplitudes which could result in coincidence counts, and interference occurs between these two biphoton amplitudes only when they are indistinguishable. 2) The BBO crystal in our experiment was only 100 /spl mu/m thick, so the two-pulse did not exist in BBO at the same time at any moment. 3) Due to the delays in the interferometer (/spl tau/ /spl tau//sub 1/), the signal-idler never met at the beamsplitter. Therefore, the existence of two-photon interference cannot be viewed as the interference between the signal and idler photons. These three points again emphasize the fact that it is the indistinguishability of the two-photon Feynman alternatives for the biphoton amplitudes which is responsible for the two-photon quantum interference effects.
Quantum computation and quantum communication require sources of entangled photons, especially from low-cost diode lasers. This study considered a polarization entangled photons pulse source produced via a spontaneous parametric down-conversion process in the type-I phase-matching of two nonlinear crystals, incorporating a continuous wave laser diode operating in pulse mode as a pump. The generated photons were measured based on visibility as a function of the pump frequency and collection apertures. A polarization correlation between photon pairs of approximately 93% and a Bell parameter S value of 2.56 ± 0.05 were obtained using the source described here.