A transportable strontium optical lattice clock towards space

Lyndsie Smith

Published Dec 1, 2016• 4 citations
OpenAlex

Abstract

This work presents the realisation and characterisation of the world’s smallest transportable optical lattice clock as part of the Space Optical Clocks 2 EU project built at the University of Birmingham. Housed in a transportable rack of dimensions 170 x 100 x 60 cm, such a device aims to measure the frequency of the doubly-forbidden 1S0−3P0 clock transition in 88Sr in an unprecedented compact apparatus as a major technological milestone towards an optical clock upon the International Space Station. A master optical clock in space would serve with unrivalled accuracy and stability to disseminate a precise and accurate reference for terrestrial clocks and the coordination of international time. Such a clock has the potential to redefine the second, revolutionise timekeeping and precision measurements, and perform fundamental science experiments in space. \nUsing a combination of novel design, innovative cooling techniques, and robust, compact commercially available products, the clock portability, robustness and operational simplicity have been improved. The apparatus simply and effectively cools and traps up to 105 88Sr atoms at a temperature of 1.3±0.2μK in an optical lattice with a lifetime of 0.52±0.01s within 400ms. The most recent preliminary clock spectroscopy measurement was 3.6 ± 0.2Hz. The instability of the clock has been measured at 8×10−17 after averaging for 300s with the goal instability being 5.8×10−17 within the same averaging time. These results show the experiment will lead transportable optical clock research and continue with the goal of being a master clock in space.

Related papers

A high-performance bosonic optical lattice clock

Stefano Origlia

Optical clocks are being developed worldwide and are at the forefront of frequency metrology. Today they outperform microwave clocks instability and inaccuracy by two orders of magnitude, raising discussion about the redefinition of the SI second. Their outstanding performances are paving the way to applications in different fields apart from metrology. Optical clocks can be used for geodetic measurements, such as chronometric levelling, and fundamental physics experiments. These applications require transportable, and even space-born optical clocks that are in development. Space optical clocks will serve as a high accurate references for intercontinental clock comparisons, and will also provide a unique test bench for fundamental physics theories, such as Einstein’s prediction of time dilation and equivalence principle. This work presents the development and characterization of a transportable strontium optical lattice clock, realised in the framework of the ESA I-SOC (Space Optical Clock on the ISS) mission. The aim of the project is to investigate new technologies and techniques, in order to develop a robust apparatus as demonstrator for space applications. Special effort has been made to reduce the size and weight of the clock, so as to meet the stringent requirements of a space mission. The system reported here is one of the most compact optical clock to date, with a total volume of only 1 m3, excluding electronics. The clock is operated with the strontium bosonic isotope 88Sr: this is preferable to the fermionic counterpart 87Sr, commonly used in optical lattice clocks, if simplicity and reliability are required. However, in terms of accuracy, bosonic clocks present some disadvantages compared with the fermionic ones, which have significantly slowed down their development for metrological applications. We characterised the relevant operating parameters and their effect on the clock accuracy and instability. Exploiting a clock laser offering an outstanding stability, we were able to demonstrate a clock fractional instability of 3×10-18 , and an inaccuracy of 2×10-17: both values represent a factor of 30 improvement compared with previous works on bosonic optical clocks. These results suggest that, in the near future, bosonic clocks may become competitive to their fermionic counterparts. This is of interest for applications such as time scale realization, transportable clocks, or for test of fundamental physics. As an example, we measured the 88Sr-87Sr isotope shift, with an uncertainty of 12 mHz.

•Jan 1, 2018•1 citation

Development of a strontium optical lattice clock for space applicationss

Singh Y., Smith L., Stefano Origlia +24 more

With timekeeping being of paramount importance for modern life, much research and major scientific advances have been undertaken in the field of frequency metrology, particularly over the last few years. New Nobel-prize winning technologies have enabled a new era of atomic clocks; namely the optical clock. These have been shown to perform significantly better than the best microwave clocks reaching an inaccuracy of 1.6 10^-18. With such results being found in large lab based apparatus, the focus now has shifted to portability - to enable the accuracy of various ground based clocks to be measured, and compact autonomous performance - to enable such technologies to be tested in space. This could lead to a master clock in space, improving not only the accuracy of technologies on which modern life has come to require such as GPS and communication networks. But also more fundamentally, this could lead to the redefinition of the second and tests of fundamental physics. Within the European collaboration, Space Optical Clocks (SOC2) consisting of various institutes and industry partners across Europe we have tried to tackle this problem of miniaturisation whilst maintaining stability, accuracy (5 10^-17) and robustness whilst keeping power consumption to a minimum -- necessary for space applications. We will present the most recent results of the Sr optical clock in SOC2 and also the novel compact design features, new methods employed and outlook.

•Jan 1, 2015•0 citations

Development of a strontium optical lattice clock for the SOC mission on the ISS

Kai Bongs, Yeshpal Singh, Lyndsie Smith +24 more

Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the “Space Optical Clocks” (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project No. 263500, during the years 2011–2015 a compact, a modular and robust strontium lattice optical clock demonstrator has been developed. The goal performance is a fractional frequency instability below 1 × 10 − 15 τ − 1 / 2 and a fractional inaccuracy below 5 × 10 − 17 . Here we describe the current status of the apparatus' development, including the laser subsystems. The robust preparation of cold 88 Sr atoms in a second-stage magneto-optical trap (MOT) is achieved.

arXiv:1503.08457•Comptes Rendus Physique•Apr 15, 2015•103 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations

The space optical clocks project

Stephan Schiller, P. Lemonde, Guglielmo Maria Tino +6 more

The Space Optical Clocks project aims at operating lattice clocks on the ISS for tests of fundamental physics and for providing high-accuracy comparisons of future terrestrial optical clocks. A pre-phase-A study (2007- 10), funded partially by ESA and DLR, included the implementation of several optical lattice clock systems using Strontium and Ytterbium as atomic species and their characterization. Subcomponents of clock demonstrators with the added specification of transportability and using techniques suitable for later space use, such as all-solid-state lasers, low power consumption, and compact dimensions, have been developed and have been validated. This included demonstration of laser-cooling and magneto-optical trapping of Sr atoms in a compact breadboard apparatus and demonstration of a transportable clock laser with 1 Hz linewidth. With two laboratory Sr lattice clock systems a number of fundamental results were obtained, such as observing atomic resonances with linewidths as low as 3 Hz, non-destructive detection of atom excitation, determination of decoherence effects and reaching a frequency instability of 1×10-16.

International Conference on Space Optics (ICSO)•Nov 20, 2017•13 citations

Advanced laser frequency stabilisation systems for mobile strontium optical lattice clocks

S. Viswam

Strontium optical lattice clocks have undergone vast developments in the past decade with world leading frequency stability and uncertainty records. Now, a lot of scientists are moving from laboratory based clocks to transportable, and portable clocks for applications including space, fundamental science, finance, and communication. The research team at the University of Birmingham are working towards developing transportable apparatus for studying fundamental physics, global positioning system (GPS), and geodesy applications. This thesis reports on the progress towards two different transportable strontium optical lattice clocks, which we will call ‘miniclock’ and ‘Space Optical lattice Clock 2’ (SOC2). \nA diode-seeded tapered amplifier based narrow linewidth laser is developed and used to realise second stage cooling of strontium in miniclock apparatus. The laser has achieved a linewidth of 1 kHz after stabilising to a 3 cm long optical reference cavity. A multiple frequency stabilisation unit (FSU) for strontium lattice clocks is established. It is a robust, portable, and compact frequency stabilisation unit with a volume of 593 cm^3. Three different lasers are currently locked simultaneously to the FSU cavity, which could be extended to any number of lasers, enabling to use a single cavity for locking all the lasers required in a strontium lattice clock, except the clock laser. FSU is designed specifically for use in compact clocks. In the SOC2 system, realisation of clock transition and its characterisation are performed. A transition linewidth of 3 Hz is obtained for the SOC2 strontium clock. Further details and results are described in the thesis.

•Jul 13, 2020•2 citations
This work presents the realisation and characterisation of the world’s smallest transportable optical lattice clock as part of the Space Optical Clocks 2 EU project built at the University of Birmingham. Housed in a transportable rack of dimensions 170 x 100 x 60 cm, such a device aims to measure the frequency of the doubly-forbidden 1S0−3P0 clock transition in 88Sr in an unprecedented compact apparatus as a major technological milestone towards an optical clock upon the International Space Station. A master optical clock in space would serve with unrivalled accuracy and stability to disseminate a precise and accurate reference for terrestrial clocks and the coordination of international time. Such a clock has the potential to redefine the second, revolutionise timekeeping and precision measurements, and perform fundamental science experiments in space. \nUsing a combination of novel design, innovative cooling techniques, and robust, compact commercially available products, the clock portability, robustness and operational simplicity have been improved. The apparatus simply and effectively cools and traps up to 105 88Sr atoms at a temperature of 1.3±0.2μK in an optical lattice with a lifetime of 0.52±0.01s within 400ms. The most recent preliminary clock spectroscopy measurement was 3.6 ± 0.2Hz. The instability of the clock has been measured at 8×10−17 after averaging for 300s with the goal instability being 5.8×10−17 within the same averaging time. These results show the experiment will lead transportable optical clock research and continue with the goal of being a master clock in space.
Optical clocks are being developed worldwide and are at the forefront of frequency metrology. Today they outperform microwave clocks instability and inaccuracy by two orders of magnitude, raising discussion about the redefinition of the SI second. Their outstanding performances are paving the way to applications in different fields apart from metrology. Optical clocks can be used for geodetic measurements, such as chronometric levelling, and fundamental physics experiments. These applications require transportable, and even space-born optical clocks that are in development. Space optical clocks will serve as a high accurate references for intercontinental clock comparisons, and will also provide a unique test bench for fundamental physics theories, such as Einstein’s prediction of time dilation and equivalence principle. This work presents the development and characterization of a transportable strontium optical lattice clock, realised in the framework of the ESA I-SOC (Space Optical Clock on the ISS) mission. The aim of the project is to investigate new technologies and techniques, in order to develop a robust apparatus as demonstrator for space applications. Special effort has been made to reduce the size and weight of the clock, so as to meet the stringent requirements of a space mission. The system reported here is one of the most compact optical clock to date, with a total volume of only 1 m3, excluding electronics. The clock is operated with the strontium bosonic isotope 88Sr: this is preferable to the fermionic counterpart 87Sr, commonly used in optical lattice clocks, if simplicity and reliability are required. However, in terms of accuracy, bosonic clocks present some disadvantages compared with the fermionic ones, which have significantly slowed down their development for metrological applications. We characterised the relevant operating parameters and their effect on the clock accuracy and instability. Exploiting a clock laser offering an outstanding stability, we were able to demonstrate a clock fractional instability of 3×10-18 , and an inaccuracy of 2×10-17: both values represent a factor of 30 improvement compared with previous works on bosonic optical clocks. These results suggest that, in the near future, bosonic clocks may become competitive to their fermionic counterparts. This is of interest for applications such as time scale realization, transportable clocks, or for test of fundamental physics. As an example, we measured the 88Sr-87Sr isotope shift, with an uncertainty of 12 mHz.
With timekeeping being of paramount importance for modern life, much research and major scientific advances have been undertaken in the field of frequency metrology, particularly over the last few years. New Nobel-prize winning technologies have enabled a new era of atomic clocks; namely the optical clock. These have been shown to perform significantly better than the best microwave clocks reaching an inaccuracy of 1.6 10^-18. With such results being found in large lab based apparatus, the focus now has shifted to portability - to enable the accuracy of various ground based clocks to be measured, and compact autonomous performance - to enable such technologies to be tested in space. This could lead to a master clock in space, improving not only the accuracy of technologies on which modern life has come to require such as GPS and communication networks. But also more fundamentally, this could lead to the redefinition of the second and tests of fundamental physics. Within the European collaboration, Space Optical Clocks (SOC2) consisting of various institutes and industry partners across Europe we have tried to tackle this problem of miniaturisation whilst maintaining stability, accuracy (5 10^-17) and robustness whilst keeping power consumption to a minimum -- necessary for space applications. We will present the most recent results of the Sr optical clock in SOC2 and also the novel compact design features, new methods employed and outlook.
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the “Space Optical Clocks” (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project No. 263500, during the years 2011–2015 a compact, a modular and robust strontium lattice optical clock demonstrator has been developed. The goal performance is a fractional frequency instability below 1 × 10 − 15 τ − 1 / 2 and a fractional inaccuracy below 5 × 10 − 17 . Here we describe the current status of the apparatus' development, including the laser subsystems. The robust preparation of cold 88 Sr atoms in a second-stage magneto-optical trap (MOT) is achieved.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.
The Space Optical Clocks project aims at operating lattice clocks on the ISS for tests of fundamental physics and for providing high-accuracy comparisons of future terrestrial optical clocks. A pre-phase-A study (2007- 10), funded partially by ESA and DLR, included the implementation of several optical lattice clock systems using Strontium and Ytterbium as atomic species and their characterization. Subcomponents of clock demonstrators with the added specification of transportability and using techniques suitable for later space use, such as all-solid-state lasers, low power consumption, and compact dimensions, have been developed and have been validated. This included demonstration of laser-cooling and magneto-optical trapping of Sr atoms in a compact breadboard apparatus and demonstration of a transportable clock laser with 1 Hz linewidth. With two laboratory Sr lattice clock systems a number of fundamental results were obtained, such as observing atomic resonances with linewidths as low as 3 Hz, non-destructive detection of atom excitation, determination of decoherence effects and reaching a frequency instability of 1×10-16.
Strontium optical lattice clocks have undergone vast developments in the past decade with world leading frequency stability and uncertainty records. Now, a lot of scientists are moving from laboratory based clocks to transportable, and portable clocks for applications including space, fundamental science, finance, and communication. The research team at the University of Birmingham are working towards developing transportable apparatus for studying fundamental physics, global positioning system (GPS), and geodesy applications. This thesis reports on the progress towards two different transportable strontium optical lattice clocks, which we will call ‘miniclock’ and ‘Space Optical lattice Clock 2’ (SOC2). \nA diode-seeded tapered amplifier based narrow linewidth laser is developed and used to realise second stage cooling of strontium in miniclock apparatus. The laser has achieved a linewidth of 1 kHz after stabilising to a 3 cm long optical reference cavity. A multiple frequency stabilisation unit (FSU) for strontium lattice clocks is established. It is a robust, portable, and compact frequency stabilisation unit with a volume of 593 cm^3. Three different lasers are currently locked simultaneously to the FSU cavity, which could be extended to any number of lasers, enabling to use a single cavity for locking all the lasers required in a strontium lattice clock, except the clock laser. FSU is designed specifically for use in compact clocks. In the SOC2 system, realisation of clock transition and its characterisation are performed. A transition linewidth of 3 Hz is obtained for the SOC2 strontium clock. Further details and results are described in the thesis.