Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Realizing three-step photoionization of calcium by two lasers

Jie Zhang, Yi Xie, Pengfei Liu, Bao-Quan Ou, Wei Wu, Ping‐Xing Chen

Published Jan 1, 2017• 8 citations
Publisher
DOI
10.1007/s00340-016-6618-2

Related papers

Isotope selective photoionization of calcium using two-step laser excitation

U. Brinkmann, W. Hartig, Harald R. Telle +1 more

Applied Physics A•Nov 1, 1974•47 citations

Two-color photoionization of calcium using SHG and LED light

Carsten Schuck, Marc Almendros, Felix Rohde +2 more

arXiv:0911.3867•Applied Physics B•Jun 2, 2010•12 citations

Two-step Selective Photoionization of Rubidium Atoms by Laser Radiation

Rafael V Ambartsumyan, В. Н. Калинин, Vladilen S Letokhov

•Mar 1, 1971•27 citations

Selective Photoionization Using Polarized Laser Beams in Two-Step Excitation of Hg Atoms

J.‐K. Han, S-P. Rho, D-Y. Jeong +4 more

Journal of the Korean Physical Society•Sep 1, 1992•1 citation

Resonant two-step photoionization of molecules: Effects of pulse sequence, pulse duration and delay time of two lasers on ionization probability and selectivity

Karin Johst, H. Johansen

Applied Physics B•Jun 1, 1989•2 citations

Isotopic selectivity calculations for multi-step photoionization of calcium atoms using narrow-band lasers

A. K. Pulhani, Gaurav Gupta, B. M. Suri

Isotopic selectivity calculations are carried out for minor calcium isotopes against the major isotope 40 Ca for the single-resonance two-step and double-resonance three-step photoionization schemes with narrow-band lasers by using spectral simulation (SS) and modified spectrum (MS) approaches. The results of these calculations are compared with the density matrix (DM) results reported in the literature. It is noted that the values of isotopic selectivity from the SS approach do not agree with those from the DM approach whereas the MS approach, considering hole burning in the Doppler-broadened atomic spectrum, predicts selectivity values which are in good agreement with the DM results. It is argued that one can adequately use the simple MS approach rather than the complex DM approach for the calculation of isotopic selectivity of multi-step photoionization with single-frequency lasers.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 21, 2002•3 citations
Isotopic selectivity calculations are carried out for minor calcium isotopes against the major isotope 40 Ca for the single-resonance two-step and double-resonance three-step photoionization schemes with narrow-band lasers by using spectral simulation (SS) and modified spectrum (MS) approaches. The results of these calculations are compared with the density matrix (DM) results reported in the literature. It is noted that the values of isotopic selectivity from the SS approach do not agree with those from the DM approach whereas the MS approach, considering hole burning in the Doppler-broadened atomic spectrum, predicts selectivity values which are in good agreement with the DM results. It is argued that one can adequately use the simple MS approach rather than the complex DM approach for the calculation of isotopic selectivity of multi-step photoionization with single-frequency lasers.