Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Infrared and Laser Engineering

Investigation of 3.39 μm IR radiance calibration based on parametric down-conversion

盛文阳 Sheng Wenyang, 李健军 Li Jianjun, 夏茂鹏 Xia Maopeng, 庞伟伟 Pang Weiwei, 高冬阳 GAO Dong-yang, 郑小兵 Zheng Xiaobing

Published Jan 1, 2016• 0 citations
Publisher
DOI
10.3788/irla201645.1004001

Related papers

Optical Radiometric Calibration Based on Parametric Down-Conversion Effect

李健军 Li Jianjun, 郑小兵 Zheng Xiaobing, 卢云君 Lu Yunjun +2 more

Acta Optica Sinica•Jan 1, 2008•0 citations

Experimental Study of Radiometer Based on Spontaneous Parametric Down-conversion Calibration

胡友勃 You-bo HU, 高冬阳 Dong-yang GAO, 李健军 Jian-jun LI +1 more

ACTA PHOTONICA SINICA•Jan 1, 2020•0 citations

Calibration technology of infrared standard transfer radiometer based on stimulated parametric down-conversion

盛文阳 Sheng Wenyang, 夏茂鹏 Xia Maopeng, 李健军 Li Jianjun +2 more

Infrared and Laser Engineering•Jan 1, 2019•0 citations

Theoretical investigation of light generated by optical parametric down-conversion and its application in the demonstration of the EPR paradox

Chao Zhao

Journal of Shanghai University (English Edition)•Apr 1, 2007•0 citations

Investigation of Two-Photon Correlation Effects in Parametric Down-Conversion

Chung Ki Hong

•Jan 1, 1988•0 citations

Investigation of Mid-Infrared Radiance Calibration Based on Parametric Amplification

Kai Li

The principle,the method and the experimental system of mid-infrared radiance calibration based on parametric amplification technique were introduced.The equation between different polarization source and its photons per mode was deduced.A high power CW laser stabilized at 532 nm was used to pump a LiNbO_3 nonlinear crystal,producing two correlated-photons whose wavelengths were 632.8 nm and 3.34μm,respectively.The under-calibrated blackbody at 3.34μm was injected along the direction of the infrared down-converted photons.With the high relativity of the VIS-IR photon pairs,through the measurement of the visible down-converted photons at 632.8 nm,the radiance of the blackbody source at 3.34μm can be calibrated and 1.53%relative standard uncertainty was reported.

Journal of Atmospheric and Environmental Optics•Jan 1, 2010•0 citations
The principle,the method and the experimental system of mid-infrared radiance calibration based on parametric amplification technique were introduced.The equation between different polarization source and its photons per mode was deduced.A high power CW laser stabilized at 532 nm was used to pump a LiNbO_3 nonlinear crystal,producing two correlated-photons whose wavelengths were 632.8 nm and 3.34μm,respectively.The under-calibrated blackbody at 3.34μm was injected along the direction of the infrared down-converted photons.With the high relativity of the VIS-IR photon pairs,through the measurement of the visible down-converted photons at 632.8 nm,the radiance of the blackbody source at 3.34μm can be calibrated and 1.53%relative standard uncertainty was reported.