Physical Review A

Contrast decay in a trapped-atom interferometer

Adèle Hilico, Cyrille Solaro, Min-Kang Zhou, M. Lopez, Franck Pereira dos Santos

Published May 18, 2015• 21 citations
Publisher

Abstract

A Ramsey-Raman interferometer is used to realize a compact force sensor using cold $^{87}\mathrm{Rb}$ atoms trapped in a vertical optical lattice. The sensitivity and accuracy of the force measurements are discussed and the limits in short-term sensitivity evaluated. We reach a relative sensitivity on the Bloch frequency and thus on the gravity acceleration of $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ at 1 s. We perform an experimental study of the influence of the transverse confinement onto the decay of the interferometer contrast and compare the measurements with a simple semiclassical model. It is shown that vertical gradients of the trapping potential can contribute significantly to the loss of contrast.

DOI
10.1103/physreva.91.053616

Related papers

A trapped ultracold atom force sensor with a μm-scale spatial resolution

Xavier Alauze, Alexis Bonnin, Cyrille Solaro +1 more

We report on the use of an ultracold ensemble of 87 Rb atoms trapped in a vertical lattice as a source for a quantum force sensor based on a Ramsey–Raman type interferometer. We reach spatial resolution in the low micrometer range in the vertical direction thanks to evaporative cooling down to ultracold temperatures in a crossed optical dipole trap. In this configuration, the coherence time of the atomic ensemble is degraded by inhomogeneous dephasing arising from atomic interactions. By weakening the confinement in the transverse direction only, we dilute the cloud and drastically reduce the strength of these interactions, without affecting the vertical resolution. This allows us to maintain an excellent relative sensitivity on the Bloch frequency, which is related to the local gravitational force, of 5 × 10 −6 at 1 s which integrates down to 8 × 10 −8 after one hour averaging time.

arXiv:1807.05860•New Journal of Physics•Jul 31, 2018•33 citations

State-labeling Wannier-Stark atomic interferometers

Bruno Pelle, Adèle Hilico, Gunnar Tackmann +2 more

Using cold ${}^{87}$Rb atoms trapped in a one-dimensional (1D)-optical lattice, atomic interferometers involving coherent superpositions between different Wannier-Stark atomic states are realized. Two different kinds of trapped interferometer schemes are presented: a Ramsey-type interferometer sensitive both to clock frequency and external forces, and a symmetric accordion-type interferometer, sensitive to external forces only. We evaluate the limits in terms of sensitivity and accuracy of those schemes and discuss their application as force sensors. As a first step, we apply these interferometers to the measurement of the Bloch frequency and the demonstration of a compact gravimeter.

arXiv:1301.5415•Physical Review A•Feb 4, 2013•36 citations

Sensitivity limits of a Raman atom interferometer as a gravity gradiometer

Fiodor Sorrentino, Quentin Bodart, L. Cacciapuoti +5 more

We evaluate the sensitivity of a dual cloud atom interferometer to the measurement of vertical gravity gradient. We study the influence of most relevant experimental parameters on noise and long term drifts. Results are also applied to the case of doubly differential measurements of the gravitational signal from local source masses. We achieve a short-term sensitivity of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}$ g/$\sqrt{\text{Hz}}$ to differential gravity acceleration, limited by the quantum projection noise of the instrument. Active control of the most critical parameters allows us to reach a resolution of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ g after 8000 s on the measurement of differential gravity acceleration. The long-term stability is compatible with a measurement of the gravitational constant $G$ at the level of ${10}^{\ensuremath{-}4}$ after an integration time of about 100 h.

arXiv:1312.3741•Physical Review A•Feb 10, 2014•241 citations

Atom Interferometry with Trapped Fermi Gases

G. Roati, Estefania de Mirandés, Francesca Ferlaino +3 more

We realize an interferometer with an atomic Fermi gas trapped in an optical lattice under the influence of gravity. The single-particle interference between the eigenstates of the lattice results in macroscopic Bloch oscillations of the sample. The absence of interactions between fermions allows a time-resolved study of many periods of the oscillations, leading to a sensitive determination of the acceleration of gravity. The experiment proves the superiority of noninteracting fermions with respect to bosons for precision interferometry and offers a way for the measurement of forces with microscopic spatial resolution.

arXiv:cond-mat/0402328•Physical Review Letters•Jun 8, 2004•210 citations

Cold atom interferometry in optical potentials

Gordon McDonald

This thesis describes recent experiments conducted on a Bose-Einstein condensate in an optical waveguide. This optical potential confines the atoms against gravity in the vertical dimension, guiding them to freely propagate in the horizontal. Being supported against gravity enables long expansion times of hundreds of milliseconds, facilitating techniques such as delta-kick cooling. In an ideal atom interferometer, the beamsplitters would impart a large momentum splitting between the interfering states in order to increase the signal. However, their effective use requires both an even narrower momentum width source and good vibration isolation. Three such techniques were investigated in this thesis: reflection from a repulsive light potential barrier, Bragg transitions from an optical lattice (which are effectively bouncing atoms off a moving grating), and Bloch-acceleration by loading the atoms into such an optical lattice and then accelerating the combined system. It is found that a combination of both Bragg and Bloch provides the most promising route to truly large momentum transfer in a system which is sensitive only to acceleration. Lastly, large-momentum transfer techniques can be used to effectively increase the way in which the output signal scales with time, creating interferometers which generate the same sensitivity faster (increasing the bandwidth of a sensor), or generate a much better sensitivity in the same time. We form a dual condensate of both rubidium-85 an rubidium-87 via sympathetic cooling. The collisional properties of Rubidium-85 can be modified by applying an external magnetic field, at an easy-to-experimentally-reach value of between 150-170G. It turns out that this combination of atomic isotopes is ideal for an interferometric test of the weak equivalence principle, one of the underpinnings of General Relativity. This thesis also presents the results of the first Bose-condensed version of such a dual-species interferometer. By removing any 87Rb left after condensation, we have created a pure 85Rb BEC. Using this we can now explore how the inter-atomic interactions affect the phase shift of a condensed atom interferometer, as we have complete control over the interaction strength. A condensate with no inter-particle interactions should behave like an ideal particle. With a small attractive interaction between atoms, it is possible to create a self-trapped cloud of atoms which propagates dispersionlessly. This cloud is known as a soliton, and it is predicted to have even more interesting quantum mechanical properties. For example it is predicted that by colliding two such solitons, an entangled state can be generated. Our results indicate that the dispersionless character of the soliton out-performs all other interaction strengths in an atom interferometer, including even the non-interacting cloud.

•Jan 1, 2015•0 citations

Atom-interferometric techniques for measuring uniform magnetic field gradients and gravitational acceleration

B. Barrett, I. Y. Chan, Anantharaman Kumarakrishnan

We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of ${}^{85}$Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of $B$ gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, $g$.

arXiv:1104.4577•Physical Review A•Dec 19, 2011•29 citations
A Ramsey-Raman interferometer is used to realize a compact force sensor using cold 87Rb^{87}\mathrm{Rb}87Rb atoms trapped in a vertical optical lattice. The sensitivity and accuracy of the force measurements are discussed and the limits in short-term sensitivity evaluated. We reach a relative sensitivity on the Bloch frequency and thus on the gravity acceleration of 3.9\ifmmode×\else\texttimes\fi10\ensuremath−63.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}3.9\ifmmode×\else\texttimes\fi10\ensuremath−6 at 1 s. We perform an experimental study of the influence of the transverse confinement onto the decay of the interferometer contrast and compare the measurements with a simple semiclassical model. It is shown that vertical gradients of the trapping potential can contribute significantly to the loss of contrast.
We report on the use of an ultracold ensemble of 87 Rb atoms trapped in a vertical lattice as a source for a quantum force sensor based on a Ramsey–Raman type interferometer. We reach spatial resolution in the low micrometer range in the vertical direction thanks to evaporative cooling down to ultracold temperatures in a crossed optical dipole trap. In this configuration, the coherence time of the atomic ensemble is degraded by inhomogeneous dephasing arising from atomic interactions. By weakening the confinement in the transverse direction only, we dilute the cloud and drastically reduce the strength of these interactions, without affecting the vertical resolution. This allows us to maintain an excellent relative sensitivity on the Bloch frequency, which is related to the local gravitational force, of 5 × 10 −6 at 1 s which integrates down to 8 × 10 −8 after one hour averaging time.
Using cold 87{}^{87}87Rb atoms trapped in a one-dimensional (1D)-optical lattice, atomic interferometers involving coherent superpositions between different Wannier-Stark atomic states are realized. Two different kinds of trapped interferometer schemes are presented: a Ramsey-type interferometer sensitive both to clock frequency and external forces, and a symmetric accordion-type interferometer, sensitive to external forces only. We evaluate the limits in terms of sensitivity and accuracy of those schemes and discuss their application as force sensors. As a first step, we apply these interferometers to the measurement of the Bloch frequency and the demonstration of a compact gravimeter.
We evaluate the sensitivity of a dual cloud atom interferometer to the measurement of vertical gravity gradient. We study the influence of most relevant experimental parameters on noise and long term drifts. Results are also applied to the case of doubly differential measurements of the gravitational signal from local source masses. We achieve a short-term sensitivity of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}$ g/Hz\sqrt{\text{Hz}}Hz​ to differential gravity acceleration, limited by the quantum projection noise of the instrument. Active control of the most critical parameters allows us to reach a resolution of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ g after 8000 s on the measurement of differential gravity acceleration. The long-term stability is compatible with a measurement of the gravitational constant GGG at the level of ${10}^{\ensuremath{-}4}$ after an integration time of about 100 h.
We realize an interferometer with an atomic Fermi gas trapped in an optical lattice under the influence of gravity. The single-particle interference between the eigenstates of the lattice results in macroscopic Bloch oscillations of the sample. The absence of interactions between fermions allows a time-resolved study of many periods of the oscillations, leading to a sensitive determination of the acceleration of gravity. The experiment proves the superiority of noninteracting fermions with respect to bosons for precision interferometry and offers a way for the measurement of forces with microscopic spatial resolution.
This thesis describes recent experiments conducted on a Bose-Einstein condensate in an optical waveguide. This optical potential confines the atoms against gravity in the vertical dimension, guiding them to freely propagate in the horizontal. Being supported against gravity enables long expansion times of hundreds of milliseconds, facilitating techniques such as delta-kick cooling. In an ideal atom interferometer, the beamsplitters would impart a large momentum splitting between the interfering states in order to increase the signal. However, their effective use requires both an even narrower momentum width source and good vibration isolation. Three such techniques were investigated in this thesis: reflection from a repulsive light potential barrier, Bragg transitions from an optical lattice (which are effectively bouncing atoms off a moving grating), and Bloch-acceleration by loading the atoms into such an optical lattice and then accelerating the combined system. It is found that a combination of both Bragg and Bloch provides the most promising route to truly large momentum transfer in a system which is sensitive only to acceleration. Lastly, large-momentum transfer techniques can be used to effectively increase the way in which the output signal scales with time, creating interferometers which generate the same sensitivity faster (increasing the bandwidth of a sensor), or generate a much better sensitivity in the same time. We form a dual condensate of both rubidium-85 an rubidium-87 via sympathetic cooling. The collisional properties of Rubidium-85 can be modified by applying an external magnetic field, at an easy-to-experimentally-reach value of between 150-170G. It turns out that this combination of atomic isotopes is ideal for an interferometric test of the weak equivalence principle, one of the underpinnings of General Relativity. This thesis also presents the results of the first Bose-condensed version of such a dual-species interferometer. By removing any 87Rb left after condensation, we have created a pure 85Rb BEC. Using this we can now explore how the inter-atomic interactions affect the phase shift of a condensed atom interferometer, as we have complete control over the interaction strength. A condensate with no inter-particle interactions should behave like an ideal particle. With a small attractive interaction between atoms, it is possible to create a self-trapped cloud of atoms which propagates dispersionlessly. This cloud is known as a soliton, and it is predicted to have even more interesting quantum mechanical properties. For example it is predicted that by colliding two such solitons, an entangled state can be generated. Our results indicate that the dispersionless character of the soliton out-performs all other interaction strengths in an atom interferometer, including even the non-interacting cloud.
We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of 85{}^{85}85Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of BBB gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, ggg.