Frontiers in Optics

Spatial Squeezing in Bright Twin Light Beams using a CCD Camera

Ashok Kumar, Hayden Nunley, Alberto M. Marino

Published Jan 1, 2016• 0 citations
Publisher

Abstract

We report the direct measurement of 2 dB of spatial squeezing with an EMCCD camera. We use bright twin beams of light generated through four-wave mixing in a double-lambda configuration in Rb atomic vapor.
DOI
10.1364/fio.2016.jth2a.2

Related papers

Spatial squeezing in bright twin beams generated with four-wave mixing: Constraints on characterization with an electron-multiplying charge-coupled-device camera

Ashok Kumar, Alberto M. Marino

The observation of spatial quantum noise reduction, or spatial squeezing, with a large number of photons can lead to a significant advantage in quantum imaging and quantum metrology due to the scaling of the signal-to-noise ratio with the number of photons. Here we present a systematic study of the limiting factors that play a role on the measurement of spatial squeezing with an electron-multiplying charge-coupled device (EMCCD) camera in the limit of bright quantum states of light generated with a four-wave mixing process in an atomic vapor cell. We detect a total number of photons per beam of the order ${10}^{8}$ in $1\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\mathrm{s}$ pulses, which corresponds to a photon flux per beam of the order of ${10}^{14}$ photons per second. We then investigate the role of different parameters, such as cell temperature, pump power, laser detunings, scattered pump background noise, and timing sequences for the image acquisition with the EMCCD camera, on the level of spatial squeezing. We identify critical parameters to obtain an optimum squeezing level and demonstrate that for bright beams it is essential to acquire images at a rate fast enough to overcome the effect of classical technical noise.

arXiv:1911.06034•Physical Review A•Dec 16, 2019•18 citations

Generation of 87Rb resonant bright two-mode squeezed light with four-wave mixing

Saesun Kim, Alberto M. Marino

Squeezed states of light have found their way into a number of applications in quantum-enhanced metrology due to their reduced noise properties. In order to extend such an enhancement to metrology experiments based on atomic ensembles, an efficient light-atom interaction is required. Thus, there is a particular interest in generating narrow-band squeezed light that is on atomic resonance. This will make it possible not only to enhance the sensitivity of atomic based sensors, but also to deterministically entangle two distant atomic ensembles. We generate bright two-mode squeezed states of light, or twin beams, with a non-degenerate four-wave mixing (FWM) process in hot $^{85}$Rb in a double-lambda configuration. Given the proximity of the energy levels in the D1 line of $^{85}$Rb and $^{87}$Rb, we are able to operate the FWM in $^{85}$Rb in a regime that generates two-mode squeezed states in which both modes are simultaneously on resonance with transitions in the D1 line of $^{87}$Rb, one mode with the $F=2$ to $F'=2$ transition and the other one with the $F=1$ to $F'=1$ transition. For this configuration, we obtain an intensity difference squeezing level of $-3.5$ dB. Moreover, the intensity difference squeezing increases to $-5.4$ dB and $-5.0$ dB when only one of the modes of the squeezed state is resonant with the D1 $F=2$ to $F'=2$ or $F=1$ to $F'=1$ transition of $^{87}$Rb, respectively.

arXiv:1806.04797•Optics Express•Dec 7, 2018•35 citations

Bright Beams of Intensity Difference Squeezed Light for use in Sub-shot-noise Imaging

Rory W. Speirs, Nicholas R. Brewer, Mong-Chang Wu +1 more

We present a method for using bright beams of intensity difference squeezed light to perform sub-shot-noise imaging. The intensity correlated twin beams are generated by four wave mixing in rubidium vapour.

Conference on Lasers and Electro-Optics•May 5, 2019•0 citations

Bright Beams of Intensity Difference Squeezed Light for use in Sub-shot-noise Imaging

Rory W. Speirs, Nicholas R. Brewer, Meng-Chang Wu +1 more

We present a method for using bright beams of intensity difference squeezed light to perform sub-shot-noise imaging. The intensity correlated twin beams are generated by four wave mixing in rubidium vapour.

Conference on Lasers and Electro-Optics•Jan 1, 2019•0 citations

Strong Relative-Intensity Squeezing of Light from Four-Wave Mixing in Hot Rb Vapor

Paul D. Lett, Vincent Boyer, Alberto M. Marino +2 more

We use nondegenerate four-wave mixing in hot atomic vapor to generate up to −7.1dB of relative-intensity squeezing between the probe and conjugate beams. This narrowband, multispatial-mode, squeezed light near an atomic resonance is of interest for image processing as well as experiments involving atomic ensembles.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2007•1 citation

Generation of narrowband twin beams for atomic manipulation

Vincent Boyer, Colin F. McCormick, E. Arimondo +2 more

We have demonstrated 3dB relative intensity squeezing from a non-degenerate four-wave mixing scheme in hot atomic rubidium vapor. The generated twin beams are narrowband and are suitable for atomic manipulation.

Frontiers in Optics•Jan 1, 2006•0 citations
The observation of spatial quantum noise reduction, or spatial squeezing, with a large number of photons can lead to a significant advantage in quantum imaging and quantum metrology due to the scaling of the signal-to-noise ratio with the number of photons. Here we present a systematic study of the limiting factors that play a role on the measurement of spatial squeezing with an electron-multiplying charge-coupled device (EMCCD) camera in the limit of bright quantum states of light generated with a four-wave mixing process in an atomic vapor cell. We detect a total number of photons per beam of the order 108{10}^{8}108 in $1\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\mathrm{s}$ pulses, which corresponds to a photon flux per beam of the order of 1014{10}^{14}1014 photons per second. We then investigate the role of different parameters, such as cell temperature, pump power, laser detunings, scattered pump background noise, and timing sequences for the image acquisition with the EMCCD camera, on the level of spatial squeezing. We identify critical parameters to obtain an optimum squeezing level and demonstrate that for bright beams it is essential to acquire images at a rate fast enough to overcome the effect of classical technical noise.
Squeezed states of light have found their way into a number of applications in quantum-enhanced metrology due to their reduced noise properties. In order to extend such an enhancement to metrology experiments based on atomic ensembles, an efficient light-atom interaction is required. Thus, there is a particular interest in generating narrow-band squeezed light that is on atomic resonance. This will make it possible not only to enhance the sensitivity of atomic based sensors, but also to deterministically entangle two distant atomic ensembles. We generate bright two-mode squeezed states of light, or twin beams, with a non-degenerate four-wave mixing (FWM) process in hot 85^{85}85Rb in a double-lambda configuration. Given the proximity of the energy levels in the D1 line of 85^{85}85Rb and 87^{87}87Rb, we are able to operate the FWM in 85^{85}85Rb in a regime that generates two-mode squeezed states in which both modes are simultaneously on resonance with transitions in the D1 line of 87^{87}87Rb, one mode with the F=2F=2F=2 to F′=2F'=2F′=2 transition and the other one with the F=1F=1F=1 to F′=1F'=1F′=1 transition. For this configuration, we obtain an intensity difference squeezing level of −3.5-3.5−3.5 dB. Moreover, the intensity difference squeezing increases to −5.4-5.4−5.4 dB and −5.0-5.0−5.0 dB when only one of the modes of the squeezed state is resonant with the D1 F=2F=2F=2 to F′=2F'=2F′=2 or F=1F=1F=1 to F′=1F'=1F′=1 transition of 87^{87}87Rb, respectively.