Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Improving the phase sensitivity of a Mach–Zehnder interferometer via a nonlinear phase shifter

Chaoping Wei, Zhi‐Ming Zhang

Published Nov 28, 2016• 12 citations
Publisher

Abstract

We propose a scheme to improve the phase sensitivity of a Mach–Zehnder interferometer. In this scheme, a Kerr nonlinear phase shifter is used to replace the traditional linear phase shifter. We consider two detection approaches: the direct homodyne detection (DHD) and the indirect homodyne detection (IHD). We find that the Kerr nonlinear phase shifter can improve the phase sensitivity of the interferometer, and the DHD is better than the IHD. In addition, we also find that the phase sensitivity of the Kerr nonlinear interferometer is robust against photon losses.

DOI
10.1080/09500340.2016.1260777

Related papers

Nonlinear phase estimation enhanced by an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Keye Zhang, L. Q. Chen +2 more

A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.

arXiv:2009.08059•Physical Review A•Sep 21, 2020•27 citations

Enhancing Phase Estimation in a Hybrid Interferometer via Kerr Nonlinearity and Photon Subtraction

Lifen Guo, Qingqian Kang, Zekun Zhao +5 more

We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling ($1/N$), and approach the super-Heisenberg scaling ($1/N^{2}$)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ $1/N^{2}$ is the ultimate precision limit permitted by the $k=2$ Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.

quant-pharXiv:2605.20893•May 21, 2026•0 citations

Improved linear and Kerr nonlinear phase estimation via photon addition operations

Zekun Zhao, Qingqian Kang, Shoukang Chang +4 more

Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.

arXiv:2505.16123•Communications in Theoretical Physics•Feb 4, 2026•2 citations

Enhanced phase sensitivity in a Mach-Zehnder interferometer via photon recycling

Dong Li, Chun-Hua Yuan, Xiaoping Ma +4 more

We propose an alternative scheme for phase estimation in a Mach-Zehnder interferometer (MZI) with photon recycling. It is demonstrated that with the same coherent-state input and homodyne detection, our proposal possesses a phase sensitivity beyond the traditional MZI. For instance, it can achieve an enhancement factor of ∼9.32 in the phase sensitivity compared with the conventional scheme even with a photon loss of 10% on the photon-recycled arm. From another point of view, the quantum Cramér-Rao bound (QCRB) is also investigated. It is found that our scheme is able to achieve a lower QCRB than the traditional one. Intriguingly, the QCRB of our scheme is dependent of the phase shift ϕ while the traditional scheme has a constant QCRB regardless of the phase shift. Finally, we present the underlying mechanisms behind the enhanced phase sensitivity. We believe that our results provide another angle from which to enhance the phase sensitivity in a MZI via photon recycling.

arXiv:2302.08717•Optics Express•Jan 26, 2023•3 citations

Phase Sensitivity of Lossy Mach–Zehnder Interferometer via Photon Addition Operation

Qisi Zhou, Qingqian Kang, Teng Zhao +3 more

ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj

arXiv:2510.17128•Advanced Quantum Technologies•Dec 1, 2025•0 citations

Optimization of the phase sensitivity through photon-subtraction inside the Mach-Zehnder interferometer

Qisi Zhou, Qingqian Kang, Teng Zhao +3 more

Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.

arXiv:2505.04499•Journal of Physics B Atomic Molecular and Optical Physics•Apr 22, 2026•3 citations
We propose a scheme to improve the phase sensitivity of a Mach–Zehnder interferometer. In this scheme, a Kerr nonlinear phase shifter is used to replace the traditional linear phase shifter. We consider two detection approaches: the direct homodyne detection (DHD) and the indirect homodyne detection (IHD). We find that the Kerr nonlinear phase shifter can improve the phase sensitivity of the interferometer, and the DHD is better than the IHD. In addition, we also find that the phase sensitivity of the Kerr nonlinear interferometer is robust against photon losses.
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling (1/N1/N1/N), and approach the super-Heisenberg scaling (1/N21/N^{2}1/N2)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ 1/N21/N^{2}1/N2 is the ultimate precision limit permitted by the k=2k=2k=2 Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.
Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.
We propose an alternative scheme for phase estimation in a Mach-Zehnder interferometer (MZI) with photon recycling. It is demonstrated that with the same coherent-state input and homodyne detection, our proposal possesses a phase sensitivity beyond the traditional MZI. For instance, it can achieve an enhancement factor of ∼9.32 in the phase sensitivity compared with the conventional scheme even with a photon loss of 10% on the photon-recycled arm. From another point of view, the quantum Cramér-Rao bound (QCRB) is also investigated. It is found that our scheme is able to achieve a lower QCRB than the traditional one. Intriguingly, the QCRB of our scheme is dependent of the phase shift ϕ while the traditional scheme has a constant QCRB regardless of the phase shift. Finally, we present the underlying mechanisms behind the enhanced phase sensitivity. We believe that our results provide another angle from which to enhance the phase sensitivity in a MZI via photon recycling.
ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj
Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.