A procedure for determining the phase shift induced by atom-atom interactions in a light-pulse atom interferometer is described, and it is shown that this shift can have substantial effects on the precision of the measurements and the applicability of certain types of interferometer set-ups to particular types of measurements.
The use of a Raman laser generated by modulation for a light-pulse atom interferometer allows for a laser system that is compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this article, we present a precise calculation of the phase shift induced by the additional laser frequencies. The model is validated by comparison with experimental measurements on an atom gravimeter. The uncertainty of the phase-shift determination limits the accuracy of our compact gravimeter to $8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\text{m}/{\text{s}}^{2}$. We show that it is possible to reduce this inaccuracy considerably with a better control of experimental parameters or with particular interferometer configurations.
We report on an original and simple formulation of the phase shift in N-light-pulse atom interferometers. We consider atomic interferometers based on two-photon transitions (Raman transitions or Bragg pulses). Starting from the exact analytical phase shift formula obtained from the atom optics ABCD formalism, we use a power series expansion in time of the position of the atomic wave packet with respect to the initial condition. The result of this expansion leads to a formulation of the interferometer phase shift where the leading coefficient in the phase terms up to T^k dependences (k >= 0) in the time separation T between pulses, can be simply expressed in terms of a product between a Vandermonde matrix, and a vector characterizing the two-photon pulse sequence of the interferometer. This simple coefficient dependence of the phase shift reflects very well the atom interferometer's sensitivity to a specific inertial field in the presence of multiple gravito-inertial effects. Consequently,we show that this formulation is well suited when looking for selective atomic sensors of accelerations, rotations, or photon recoil only, which can be obtained by simply zeroing some specific coefficients. We give a theoritical application of our formulation to the photon recoil measurement.
Atom interferometry relies on the separation and recombination of atom wavepackets. When the two paths overlap perfectly at the end of the interferometer, the phase is insensitive to the atomic velocity distribution. Here, we show that, when the separation and recombination is performed using a Raman transition there is a displacement of the atomic wavepacket due to a phase shift during light pulses. Because of the variation of the laser intensity seen by the atoms, there is an imperfect cancellation of these displacements. The observation of a velocity-dependent phase shift on the interferometer is the signature of this effect, which has been modeled. Thanks to the signature we have identified, we are able to compensate for this effect by applying laser power ramps during the interferometer to mitigate intensity variations.
The sensitivity of atom interferometers depends on the fidelity of the light pulses used as beamsplitters and mirrors. Atom interferometers typically employ pulses that affect π/2 and π fractional Rabi oscillations, the fidelities of which are reduced when there are variations in atomic velocity and laser intensity. We have previously demonstrated the application of optimal control theory to design pulses more robust to such errors; however, if these variations exhibit a time dependence over periods on the order of the interferometer duration then phase shifts can be introduced in the final fringe that potentially reduce the sensitivity. In this paper, we explain why care must be taken when optimising interferometer pulse sequences to ensure that phase shifts arising from inter-pulse variations are not significantly increased. We show that these phase shifts can in fact be minimised by choosing an appropriate measure of individual pulse fidelity.