Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Narrow linewidth CPT signal in small vapor cells for chip scale atomic clocks

Miao Zhu, Leonard S. Cutler, J.E. Berberian, Jeff F. DeNatale, Philip A. Stupar, Chailun Tsai

Published Apr 12, 2005• 7 citations
Publisher

Abstract

We report our measurement of coherent-population-trapping (CPT) signal linewidths in small vapor cells, which are desirable for chip scale atomic clock (CSAC) applications. The linewidths are measured in both rubidium vapor cells and cesium vapor cells. Using a micro-machined silicon absorption cell (diameter = 1.7 mm, length = 2 mm), we demonstrate a sub-kHz linewidth (FWHM) of the clock transition in the /sup 133/Cs atom (|F = 3, m/sub F/ = 0>/spl harr/|F = 4, m/sub F/ = 0>). The measured intrinsic linewidths (FWHM = 777 Hz for Cs and FWHM = 1496 Hz for Rb) of the cells agree with the calculated results.

DOI
10.1109/freq.2004.1418435

Related papers

Study on characteristics of coherent population trapping spectral line for chip-scale atomic clock

Yi Yin, Yi Zhang, Tan Bo-Zhong +2 more

To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.

Acta Physica Sinica•Jan 1, 2015•1 citation

Ultra-Compact Frequency Standards Using CPT Phenomenon

Kyoya Fukuda

In recent years, the coherent population trapping (CPT) phenomenon using a very small cell has attracted considerable attention for its potential application to ultra-compact atomic clock. For the miniaturization of CPT clock, it is important to clarify influence by the collision with atoms and cell walls. We study the effect of cell geometry on the CPT spectrum using a thin Cs vapor cell without buffer gas. When the cell length is below 1 mm and the laser intensity is sufficiently weak, the transit-time broadening is largely suppressed because only slow atoms have enough time to settle down on the dark state and contribute to the CPT signals. Furthermore, we show that introduction of buffer gas may broaden the CPT resonance in extremely thin cells. We also show that sub-Doppler signal which can be used for stabilization of laser frequency is obtained by using the CPT signal.

The Review of Laser Engineering•Jan 1, 2007•1 citation

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

Fabrication of Cesium Vapor Cells for Chip-Scale Atomic Clock Based on Coherent Population Trapping

Alexey Kazakin, Yu. D. Akul'shin, Yakov Enns +3 more

The article presents the results of the development, fabrication and investigation of miniature cesium vapor cells for quantum frequency standards with optical pumping, working on the effect of coherent population trapping. Microelectromechanical systems technologies were used in the manufacture of cells. For the first time, the dry silicon etching in inductively coupled plasma of sulfur hexafluoride and freon gas in a mixed mode was used to form internal cavities of cells with a thickness of 1.5 mm. Vacuum-tight sealing of cells containing a solid-state source of cesium vapor and buffer gas was carried out by anodic bonding of glass and silicon in a neon atmosphere. The coherent population trapping signal with a linewidth of 750 Hz and a signal-to-noise ratio of 1190 in the 1-Hz bandwidth was observed. Experimental results show that these microcells are appropriate for applications to atomic clock with a relative frequency stability of$6\cdot 10^{-11}$at 1 s.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 20, 2022•1 citation

Microfabricated cells for chip-scale atomic clock based on coherent population trapping: Fabrication and investigation

Ермак Сергей Викторович, V. V. Semenov, Пятышев Евгений Нилович +5 more

A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.

St Petersburg Polytechnical University Journal Physics and Mathematics•Mar 1, 2015•10 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•9 citations
We report our measurement of coherent-population-trapping (CPT) signal linewidths in small vapor cells, which are desirable for chip scale atomic clock (CSAC) applications. The linewidths are measured in both rubidium vapor cells and cesium vapor cells. Using a micro-machined silicon absorption cell (diameter = 1.7 mm, length = 2 mm), we demonstrate a sub-kHz linewidth (FWHM) of the clock transition in the /sup 133/Cs atom (|F = 3, m/sub F/ = 0>/spl harr/|F = 4, m/sub F/ = 0>). The measured intrinsic linewidths (FWHM = 777 Hz for Cs and FWHM = 1496 Hz for Rb) of the cells agree with the calculated results.
To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.
In recent years, the coherent population trapping (CPT) phenomenon using a very small cell has attracted considerable attention for its potential application to ultra-compact atomic clock. For the miniaturization of CPT clock, it is important to clarify influence by the collision with atoms and cell walls. We study the effect of cell geometry on the CPT spectrum using a thin Cs vapor cell without buffer gas. When the cell length is below 1 mm and the laser intensity is sufficiently weak, the transit-time broadening is largely suppressed because only slow atoms have enough time to settle down on the dark state and contribute to the CPT signals. Furthermore, we show that introduction of buffer gas may broaden the CPT resonance in extremely thin cells. We also show that sub-Doppler signal which can be used for stabilization of laser frequency is obtained by using the CPT signal.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
The article presents the results of the development, fabrication and investigation of miniature cesium vapor cells for quantum frequency standards with optical pumping, working on the effect of coherent population trapping. Microelectromechanical systems technologies were used in the manufacture of cells. For the first time, the dry silicon etching in inductively coupled plasma of sulfur hexafluoride and freon gas in a mixed mode was used to form internal cavities of cells with a thickness of 1.5 mm. Vacuum-tight sealing of cells containing a solid-state source of cesium vapor and buffer gas was carried out by anodic bonding of glass and silicon in a neon atmosphere. The coherent population trapping signal with a linewidth of 750 Hz and a signal-to-noise ratio of 1190 in the 1-Hz bandwidth was observed. Experimental results show that these microcells are appropriate for applications to atomic clock with a relative frequency stability of6⋅10−116\cdot 10^{-11}6⋅10−11at 1 s.
A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.