Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)

THz superconducting hot electron bolometer heterodyne receivers

J. R. Gao, Merlijn Hajenius, Z.Q. Yang, J. Niels Hovenier, J. J. A. Baselmans, Andrey M. Baryshev, P. Khosropanah, T. M. Klapwijk

Published Sep 1, 2006• 1 citation
Publisher

Abstract

We will highlight recent progress in superconducting NbN hot electron bolometer (HEB) mixers achieved through close collaboration between SRON and TU Delft.
DOI
10.1109/icimw.2006.368753

Related papers

Terahertz Superconducting Hot Electron Bolometer Heterodyne Receivers

J. R. Gao, Merlijn Hajenius, Zhenyu Yang +4 more

We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•29 citations

Terahertz Heterodyn Receiver with a hot-electron bolometer mixer

H.-W. Hübers, Alexej D. Semenov, Heiko Richter +6 more

During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.

•Jan 1, 2002•0 citations

Superconducting Hot-Electron Bolometer Mixer for Terahertz Heterodyne Receivers

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Heiko Richter +4 more

Softwaretechnik-Trends•Apr 1, 2003•1 citation

Noise performance of quasioptical ultrathin NbN hot-electron bolometer mixer at 2.5 and 3.8 THz

Sergey V. Antipov, Yu.B. Vachtornin, S. N. Maslennikov +5 more

To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.

International Kharkiv Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves•Oct 26, 2004•0 citations

Study on superconducting NbN hot electron bolometric mixers for THz frequency receiver

茂人 三木

•Jan 1, 2003•0 citations

Development of THz Nb diffusion-cooled hot electron bolometer mixers

J. R. Gao, Pavel A. Yagoubov, T. M. Klapwijk +3 more

We summarize our research activities on THz Nb diffusion-cooled hot electron bolometer (HEB) mixers, carried out at Space Research Organization Netherlands (SRON) and Delft University of Technology. This paper will include our understanding on the device physics of diffusion-cooled HEB mixers, noise and IF bandwidth measurements of waveguide mixers around 0.7 THz, and in particular recent measurements of Nb quasi-optical mixers at 0.64 and 2.5 THz. The waveguide devices demonstrate a receiver noise temperature of 900 K at 0.7 THz. The quasi-optical mixers show 1200 K at 0.64 THz and 4500 K at 2.5 THz and a maximum IF bandwidth of at least 5 GHz.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•8 citations
We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.
During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.
To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
We summarize our research activities on THz Nb diffusion-cooled hot electron bolometer (HEB) mixers, carried out at Space Research Organization Netherlands (SRON) and Delft University of Technology. This paper will include our understanding on the device physics of diffusion-cooled HEB mixers, noise and IF bandwidth measurements of waveguide mixers around 0.7 THz, and in particular recent measurements of Nb quasi-optical mixers at 0.64 and 2.5 THz. The waveguide devices demonstrate a receiver noise temperature of 900 K at 0.7 THz. The quasi-optical mixers show 1200 K at 0.64 THz and 4500 K at 2.5 THz and a maximum IF bandwidth of at least 5 GHz.