International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)

Compact heterodyne receiver at 2.8 THz based on a quantum cascade laser and a superconducting bolometer

Zhenyu Yang, Merlijn Hajenius, J. Niels Hovenier, Andrey M. Baryshev, J. J. A. Baselmans, J. R. Gao, T. M. Klapwijk, Aurèle J. L. Adam, Tjeerd O. Klaassen, Benjamin S. Williams, Sushil Kumar, Qing Hu, John L. Reno

Published Jan 18, 2006• 3 citations
Publisher

Abstract

We report here a sensitivity measurement of an all solid-state heterodyne receiver which uses a twin slot antenna coupled, small superconducting NbN hot electron bolometer as mixer and a semiconductor quantum cascade laser operating at 2.8 THz as local oscillator. We measure a double sideband receiver noise temperature of 3200 K at 2.8 THz and 4.2 K. We find that the optimal LO power is 33 nW measured at HEB and 1.3 /spl mu/W estimated at the QCL, much lower than the output power of the QCL. Such a receiver can be used for high-resolution spectroscopy above 2 THz and is particularly suitable for space-based observatories.

DOI
10.1109/icimw.2005.1572614

Related papers

An Ultra-High-Sensitivity Superconducting Hot-Electron-Bolometer Heterodyne Receiver at 2.5 THz With an Integrated Low-Power-Consumption Quantum Cascade Laser

Wei Miao, Hao Gao, Zheng Lou +8 more

We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.

IEEE Transactions on Terahertz Science and Technology•Sep 6, 2018•9 citations

10.6 μm heterodyne receiver based on a superconducting hot-electron bolometer mixer and a quantum cascade laser

Yuan Ren, DaiXi Zhang, Kangmin Zhou +7 more

We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.

AIP Advances•Jul 1, 2019•13 citations

3.1-THz Heterodyne Receiver Using an NbTiN Hot-Electron Bolometer Mixer and a Quantum Cascade Laser

Shoichi Shiba, Yoshihisa Irimajiri, T. Yamakura +4 more

We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.

IEEE Transactions on Terahertz Science and Technology•Dec 6, 2011•18 citations

Terahertz Superconducting Hot Electron Bolometer Heterodyne Receivers

J. R. Gao, Merlijn Hajenius, Zhenyu Yang +4 more

We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•29 citations

Low noise HEB/QCL integrated heterodyne receiver at 2.7 THz

Hao Gao, W. Miao, Z. Lou +6 more

In this paper, we present a low noise integrated heterodyne receiver at 2.7 THz. This heterodyne receiver is based on a superconducting hot electron bolometer (HEB) mixer and a low power consumption quantum cascade laser (QCL) that are both integrated on the same 4 K stage of a pulse tube cooler. We measured the noise temperature of the HEB/QCL integrated heterodyne receiver by using hot and cold blackbody loads in vacuum. The lowest double sideband receiver noise temperature is about 1000 K at 2.7 THz, and reduced to 500 K after eliminating the quasi-optical losses. In addition, the HEB/QCL integrated heterodyne receiver demonstrates an intermediate frequency (IF) noise bandwidth of 4 GHz.

IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition•May 1, 2016•1 citation

Sensitivity of a hot electron bolometer heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, Merlijn Hajenius +2 more

We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 6, 2008•0 citations
We report here a sensitivity measurement of an all solid-state heterodyne receiver which uses a twin slot antenna coupled, small superconducting NbN hot electron bolometer as mixer and a semiconductor quantum cascade laser operating at 2.8 THz as local oscillator. We measure a double sideband receiver noise temperature of 3200 K at 2.8 THz and 4.2 K. We find that the optimal LO power is 33 nW measured at HEB and 1.3 /spl mu/W estimated at the QCL, much lower than the output power of the QCL. Such a receiver can be used for high-resolution spectroscopy above 2 THz and is particularly suitable for space-based observatories.
We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.
We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.
We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.
We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.
In this paper, we present a low noise integrated heterodyne receiver at 2.7 THz. This heterodyne receiver is based on a superconducting hot electron bolometer (HEB) mixer and a low power consumption quantum cascade laser (QCL) that are both integrated on the same 4 K stage of a pulse tube cooler. We measured the noise temperature of the HEB/QCL integrated heterodyne receiver by using hot and cold blackbody loads in vacuum. The lowest double sideband receiver noise temperature is about 1000 K at 2.7 THz, and reduced to 500 K after eliminating the quasi-optical losses. In addition, the HEB/QCL integrated heterodyne receiver demonstrates an intermediate frequency (IF) noise bandwidth of 4 GHz.
We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.