Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Long-term stability dependence of the quantum magnetometers dual scheme on the correlation of their double resonance signals

A. Baranov, Ермак Сергей Викторович, R. V. Smolin, V. V. Semenov

Published May 1, 2016• 4 citations
Publisher

Abstract

We present the results of the quantum magnetometers dual scheme long-term frequency stability. Such configuration utilizes two magnetic dipole transitions (Zeeman and microwave) and a single optical path in order to reduce magnetic field variations and resonance frequency instability.
DOI
10.1109/fcs.2016.7546757

Related papers

Signal correlation in the tandem of a spin oscillator and microwave frequency discriminator with laser-pumped alkali atoms

A. A. Baranov, Ермак Сергей Викторович, E. A. Sagitov +2 more

We have studied the influence of low-frequency noise on the stability of resonance frequency of a self-oscillating magnetometer on 87Rb vapor with simultaneous monitoring of the signal of radio-optical resonance on the magnetic-field-dependent microwave transition under laser pumping at the D 2 line of the head doublet. The difference of synchronous records of detected signals reduced to the same scale in magnetic field units was processed to determine the Allan variance as a function of the averaging time. The correlation coefficient characterizing the coupling of detected signals determined by the pumping rate and intensity of radio fields generated in the region of the absorption chamber. The self-oscillating magnetometer can only operate provided that there is laser tuning to the long-wavelength component of the electric-dipole transition.

Technical Physics Letters•Feb 1, 2016•9 citations

Results of the Investigations of the Nature of the Long -Term Instability in Quantum Frequency Standards and Magnetometers

A. G. Chirkov

The problem analysis results made the author to draw a conclusion that the nature of the resonance frequency long-term instability and drift at harmonic excitation is related to the phase dynamics of the "atom + field" system in the small vicinity of the resonance. The investigation is based on the strictly substantiated asymptotic Krylov-Bogolyubov perturbation theory. A time-dependent (drift) first-order correction of the perturbing field amplitude to the resonance frequency was disclosed. It was found that this correction is always present and is responsible for the frequency drift and long-term instability. The necessary and sufficient conditions of accurate resonance, as well as the conditions of realization of a stable (stationary, steady-state) drift-free oscillation regime in a quantum system, are obtained.

arXiv:quant-ph/0510126•Oct 17, 2005•0 citations

Use of Optically Pumped Quantum Magnetometers as Signal Receivers in the Ultra-Long Wavelength Range

Ермак Сергей Викторович, Alexander Fedotovich Kryachko, V. V. Semenov +2 more

The operation of basic types of quantum magnetometers with optical pumping as signal receivers in the ultra-long wavelength range is demonstrated in this work. The circuit realization of an experimental setup, provides the registration of double radio-optical resonance signals, is discussed. The realized magnetometers sensitivity is tens of pT/Hz1/2at bandwidth up to 1 kHz. The comparison of the absorption resonance signals in operation modes of quantum magnetometers with and without of synchronous detection is done. Maximum frequency of magnetic signals is about 534 Hz. An estimate of the maximum receiving distance is about of 100 m. The spectrum of frequency-modulated magnetometer signal is discussed. Prospects and features for the use of quantum magnetometers as super-low-frequency signal receivers are presented.

Wave Electronics and its Application in Information and Telecommunication Systems (WECONF)•May 29, 2023•1 citation

A relative influence of low-frequency and microwave radio-optical resonances in alkali atoms vapor

E. A. Sagitov, Kseniia Lezhennikova, V. V. Semenov +2 more

The paper is devoted to the study of the relative influence of low-frequency and microwave signals of the system of two quantum magnetometers based on simultaneous induction of the spin generator signal on the resonance transition and the MZ-signal of the edge magnetically dependent microwave resonance. The "dressed" atom effect caused frequency shifts of low-frequency and microwave resonances is shown. The frequency shifts ratio of the spin generator to the microwave resonance was between 10 and 100, depending on the experimental conditions. The necessity of the using a circularly polarized low-frequency radio field is shown to reduce the radio-optical resonance frequency shifts caused by the mutual influence of the measuring channels of the magnetometers system.

•Jan 1, 2017•0 citations

Dual channel self-oscillating optical magnetometer

Jacopo Belfi, G. Bevilacqua, V. Biancalana +4 more

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.

arXiv:0812.1160•Journal of the Optical Society of America B•Apr 3, 2009•30 citations

Single-quadrature quantum magnetometry in cavity electromagnonics

Mehri Sadat Ebrahimi, Ali Motazedifard, M. Bagheri Harouni

A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.

arXiv:2011.06081•Physical Review A•Jun 10, 2021•50 citations
We have studied the influence of low-frequency noise on the stability of resonance frequency of a self-oscillating magnetometer on 87Rb vapor with simultaneous monitoring of the signal of radio-optical resonance on the magnetic-field-dependent microwave transition under laser pumping at the D 2 line of the head doublet. The difference of synchronous records of detected signals reduced to the same scale in magnetic field units was processed to determine the Allan variance as a function of the averaging time. The correlation coefficient characterizing the coupling of detected signals determined by the pumping rate and intensity of radio fields generated in the region of the absorption chamber. The self-oscillating magnetometer can only operate provided that there is laser tuning to the long-wavelength component of the electric-dipole transition.
The problem analysis results made the author to draw a conclusion that the nature of the resonance frequency long-term instability and drift at harmonic excitation is related to the phase dynamics of the "atom + field" system in the small vicinity of the resonance. The investigation is based on the strictly substantiated asymptotic Krylov-Bogolyubov perturbation theory. A time-dependent (drift) first-order correction of the perturbing field amplitude to the resonance frequency was disclosed. It was found that this correction is always present and is responsible for the frequency drift and long-term instability. The necessary and sufficient conditions of accurate resonance, as well as the conditions of realization of a stable (stationary, steady-state) drift-free oscillation regime in a quantum system, are obtained.
The operation of basic types of quantum magnetometers with optical pumping as signal receivers in the ultra-long wavelength range is demonstrated in this work. The circuit realization of an experimental setup, provides the registration of double radio-optical resonance signals, is discussed. The realized magnetometers sensitivity is tens of pT/Hz1/2at bandwidth up to 1 kHz. The comparison of the absorption resonance signals in operation modes of quantum magnetometers with and without of synchronous detection is done. Maximum frequency of magnetic signals is about 534 Hz. An estimate of the maximum receiving distance is about of 100 m. The spectrum of frequency-modulated magnetometer signal is discussed. Prospects and features for the use of quantum magnetometers as super-low-frequency signal receivers are presented.
The paper is devoted to the study of the relative influence of low-frequency and microwave signals of the system of two quantum magnetometers based on simultaneous induction of the spin generator signal on the resonance transition and the MZ-signal of the edge magnetically dependent microwave resonance. The "dressed" atom effect caused frequency shifts of low-frequency and microwave resonances is shown. The frequency shifts ratio of the spin generator to the microwave resonance was between 10 and 100, depending on the experimental conditions. The necessity of the using a circularly polarized low-frequency radio field is shown to reduce the radio-optical resonance frequency shifts caused by the mutual influence of the measuring channels of the magnetometers system.
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.
A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.