Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Unshielded scalar magnetometer based on nonlinear magneto-optical rotation with amplitude modulated light

Wenhao Li, Xiang Peng, Songjian Li, Chuanfei Liu, Hong Mei Guo, Pingwei Lin, Wei Zhang

Published May 1, 2016• 6 citations
Publisher

Abstract

In this article, a high-sensitivity magnetometer with paraffin-coated Cs vapor cell based on amplitude modulated nonlinear magneto-optical rotation (AM NMOR) is presented. The magnetometer has a wide dynamic range which covers the geomagnetic field range and its operation is demonstrated in an unshielded environment. The sensitivity of the magnetometer has reached sub-pT level. The main limitation to the resonance linewidth and the sensitivity is nonlinear Zeeman splitting.

DOI
10.1109/fcs.2016.7546761

Related papers

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Nonlinear magneto-optical effect in paraffin coated Rb vapor cell

Hyun Joon Lee, Ye-Jin Yu, In‐Ho Bae +1 more

Application of an atomic magnetometer based on nonlinear magneto-optical rotation(NMOR) was studied. We have observed the NMOR signals in87Rb D1line using the the Rb vapor cell coated with paraffin. The paraffin coated vapor cell lead to double structured features in the NMOR signal which have different slope value of 0.193 mrad/mG and 2.23 mrad/mG with laser power 400 muW, respectively.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Aug 1, 2009•0 citations

Magnetometric sensitivity optimization for nonlinear optical rotation with frequency-modulated light: Rubidium D2 line

Derek F. Jackson Kimball, Louis Jacome, Srikanth Guttikonda +2 more

Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).

arXiv:0906.3586•Journal of Applied Physics•Sep 15, 2009•32 citations

Magnetometry with millimeter-scale antirelaxation-coated alkali-metal vapor cells

M. V. Balabas, Dmitry Budker, John E. Kitching +2 more

Dynamic nonlinear magneto-optical-rotation signals with frequency- and amplitude-modulated laser light have been observed and investigated with a spherical glass cell of 3 mm diameter containing Cs metal with inner walls coated with paraffin. Intrinsic Zeeman relaxation rates of γ/(2π)≈20 Hz and lower have been observed. Favorable prospects of using millimeter-scale coated cells in portable magnetometers and secondary frequency references are discussed.

arXiv:physics/0511003•Journal of the Optical Society of America B•Jun 1, 2006•95 citations

Dual channel self-oscillating optical magnetometer

Jacopo Belfi, G. Bevilacqua, V. Biancalana +4 more

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.

arXiv:0812.1160•Journal of the Optical Society of America B•Apr 3, 2009•30 citations

Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range

Víctor M. Acosta, M. P. Ledbetter, Simon Rochester +7 more

Recent work investigating resonant nonlinear magneto-optical rotation (NMOR) related to long-lived $({\ensuremath{\tau}}_{\mathrm{rel}}\ensuremath{\sim}1\mathrm{s})$ ground-state atomic coherences has demonstrated potential magnetometric sensitivities exceeding ${10}^{\ensuremath{-}11}\phantom{\rule{0.3em}{0ex}}\mathrm{G}∕\sqrt{\mathrm{Hz}}$ for small $(\ensuremath{\lesssim}1\phantom{\rule{0.3em}{0ex}}\mathrm{\ensuremath{\mu}}\mathrm{G}$) magnetic fields. In the present work, NMOR using frequency-modulated light (FM NMOR) is studied in the regime where the longitudinal magnetic field is in the geophysical range$(\ensuremath{\sim}500\mathrm{mG})$, of particular interest for many applications. In this regime a splitting of the FM NMOR resonance due to the nonlinear Zeeman effect is observed. At sufficiently high light intensities, there is also a splitting of the FM NMOR resonances due to ac Stark shifts induced by the optical field, as well as evidence of alignment-to-orientation conversion type processes. The consequences of these effects for FM-NMOR-based atomic magnetometry in the geophysical field range are considered.

arXiv:physics/0602109•Physical Review A•May 17, 2006•122 citations
In this article, a high-sensitivity magnetometer with paraffin-coated Cs vapor cell based on amplitude modulated nonlinear magneto-optical rotation (AM NMOR) is presented. The magnetometer has a wide dynamic range which covers the geomagnetic field range and its operation is demonstrated in an unshielded environment. The sensitivity of the magnetometer has reached sub-pT level. The main limitation to the resonance linewidth and the sensitivity is nonlinear Zeeman splitting.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.
Recent work investigating resonant nonlinear magneto-optical rotation (NMOR) related to long-lived $({\ensuremath{\tau}}_{\mathrm{rel}}\ensuremath{\sim}1\mathrm{s})$ ground-state atomic coherences has demonstrated potential magnetometric sensitivities exceeding ${10}^{\ensuremath{-}11}\phantom{\rule{0.3em}{0ex}}\mathrm{G}∕\sqrt{\mathrm{Hz}}$ for small $(\ensuremath{\lesssim}1\phantom{\rule{0.3em}{0ex}}\mathrm{\ensuremath{\mu}}\mathrm{G}$) magnetic fields. In the present work, NMOR using frequency-modulated light (FM NMOR) is studied in the regime where the longitudinal magnetic field is in the geophysical range$(\ensuremath{\sim}500\mathrm{mG})$, of particular interest for many applications. In this regime a splitting of the FM NMOR resonance due to the nonlinear Zeeman effect is observed. At sufficiently high light intensities, there is also a splitting of the FM NMOR resonances due to ac Stark shifts induced by the optical field, as well as evidence of alignment-to-orientation conversion type processes. The consequences of these effects for FM-NMOR-based atomic magnetometry in the geophysical field range are considered.