Chinese Physics Letters

Simulation and Design of Fluorescence Collector

Hao Shi, Jie Ma, Xiaofeng Li, Jie Liu, Shougang Zhang

Published Sep 1, 2016• 5 citations
Publisher

Abstract

Fluorescence collector is a critical component in optically pumped Cs beam frequency standards. We design a new fluorescence collector by means of a new method. By means of two simulation methods, a smaller fluorescence collector with the same collection efficiency is achieved. It can be applied to almost all fluorescence detection systems in atom-light interaction experiments. We select the practical fluorescence collector studied by comparing three designing schemes. Its structure is very plain. Moreover, its fluorescence collection efficiency is very high. The collection efficiency of the practical fluorescence collector we designed is over 33% by means of two different ways.

DOI
10.1088/0256-307x/33/9/094205

Related papers

Imaging an atomic beam using fluorescence

何明, 王谨, 詹明生

A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed by a commercial CCD-camera, which is corresponding to the atomic state and velocity distribution. The detection scheme has a great utilization in the experiments of cold atoms and atomic optics.

Chinese Optics Letters•Jan 1, 2003•3 citations

Improved rubidium atomic beam clock based on lamp-pumping and fluorescence-detection scheme

Y. H. Wang, Jiayao Huang, Y. J. Gu +3 more

A compact, portable rubidium atomic beam clock based on lamp-pumping and fluorescence-detection scheme is proposed. The expected short-term frequency stability can be at least three orders of magnitude better than that of previous experimental results. The usages of lamp pumping, fluorescence detection and microwave slow-wave resonance structures make this design robust and compact.

Journal of the European Optical Society Rapid Publications•Jan 1, 2011•21 citations

Accurate measurement of the fluorescence collection efficiency in a light-atom interaction experiment

P. Cérez, V. Giordano, N. Dimarcq +2 more

The authors report an accurate method of measurement of the fluorescence collection efficiency in a resonant light-atom interaction experiment. The measurement consists in a precise comparison of the absorption and fluorescence signals. Using this technique, optimisation of the optical collecting set-up can be made as well as signal-to-noise predictions in the optical detection of atoms. It allows one to study fine physical effects such as anisotropy of the fluorescent light.

Measurement Science and Technology•Oct 1, 1990•6 citations

Photon-burst method in high-resolution laser spectroscopy

D. A. Lewis, J. F. Tonn, S. L. Kaufman +1 more

The sensitivity of high-resolution fluorescence spectroscopy has been enhanced by the detection of bursts of photons from single atoms crossing a laser beam. A tunable cw laser beam intersected a well-collimated atomic beam at right angles, and the fluorescent light was detected by an ellipsoidal collector and a photomultiplier. The passage of an atom through the beam was identified with a burst of detected photon pulses, which could be differentiated easily from the random background. For increasing burst multiplicity the spectra show improved background suppression and also significant peak narrowing. High-resolution spectra were obtained with as few as 10 atoms/sec crossing the laser beam. Statistical predictions for the case of transit-time limited signals are calculated and compared with results obtained for the Na 5890-\AA{} and Ba 5535-\AA{} transitions.

Physical Review A•Apr 1, 1979•24 citations

Hanle Detection for Optical Clocks

Xiaogang Zhang, Shengnan Zhang, Duo Pan +4 more

Considering the strong inhomogeneous spatial polarization and intensity distribution of spontaneous decay fluorescence due to the Hanle effect, we propose and demonstrate a universe Hanle detection configuration of electron-shelving method for optical clocks. Experimental results from Ca atomic beam optical frequency standard with electron-shelving method show that a designed Hanle detection geometry with optimized magnetic field direction, detection laser beam propagation and polarization direction, and detector position can improve the fluorescence collection rate by more than one order of magnitude comparing with that of inefficient geometry. With the fixed 423 nm fluorescence, the improved 657 nm optical frequency standard signal intensity is presented. The potential application of the Hanle detection geometry designed for facilitating the fluorescence collection for optical lattice clock with a limited solid angle of the fluorescence collection has been discussed. The Hanle detection geometry is also effective for ion detection in ion optical clock and quantum information experiments. Besides, a cylinder fluorescence collection structure is designed to increase the solid angle of the fluorescence collection in Ca atomic beam optical frequency standard.

arXiv:1404.4431•The Scientific World JOURNAL•Jan 1, 2015•4 citations

Detection of optical resonances by observation of fluorescence light emitted from a fast atomic beam when optical pumping occurs

H. T. Duong, Jean Vialle

The sensitivity of the method of detection of optical resonances by observation of the fluorescence light emitted from a fast beam excited by a laser in collinear geometry is often limited by the optical pumping. In our method, we propose to take advantage of the optical pumping process to detect optical resonances by using a second laser beam in almost collinear geometry which acts as a detector of optical pumping.

Journal de Physique Lettres•Jan 1, 1980•1 citation
Fluorescence collector is a critical component in optically pumped Cs beam frequency standards. We design a new fluorescence collector by means of a new method. By means of two simulation methods, a smaller fluorescence collector with the same collection efficiency is achieved. It can be applied to almost all fluorescence detection systems in atom-light interaction experiments. We select the practical fluorescence collector studied by comparing three designing schemes. Its structure is very plain. Moreover, its fluorescence collection efficiency is very high. The collection efficiency of the practical fluorescence collector we designed is over 33% by means of two different ways.
The sensitivity of high-resolution fluorescence spectroscopy has been enhanced by the detection of bursts of photons from single atoms crossing a laser beam. A tunable cw laser beam intersected a well-collimated atomic beam at right angles, and the fluorescent light was detected by an ellipsoidal collector and a photomultiplier. The passage of an atom through the beam was identified with a burst of detected photon pulses, which could be differentiated easily from the random background. For increasing burst multiplicity the spectra show improved background suppression and also significant peak narrowing. High-resolution spectra were obtained with as few as 10 atoms/sec crossing the laser beam. Statistical predictions for the case of transit-time limited signals are calculated and compared with results obtained for the Na 5890-\AA{} and Ba 5535-\AA{} transitions.
Considering the strong inhomogeneous spatial polarization and intensity distribution of spontaneous decay fluorescence due to the Hanle effect, we propose and demonstrate a universe Hanle detection configuration of electron-shelving method for optical clocks. Experimental results from Ca atomic beam optical frequency standard with electron-shelving method show that a designed Hanle detection geometry with optimized magnetic field direction, detection laser beam propagation and polarization direction, and detector position can improve the fluorescence collection rate by more than one order of magnitude comparing with that of inefficient geometry. With the fixed 423 nm fluorescence, the improved 657 nm optical frequency standard signal intensity is presented. The potential application of the Hanle detection geometry designed for facilitating the fluorescence collection for optical lattice clock with a limited solid angle of the fluorescence collection has been discussed. The Hanle detection geometry is also effective for ion detection in ion optical clock and quantum information experiments. Besides, a cylinder fluorescence collection structure is designed to increase the solid angle of the fluorescence collection in Ca atomic beam optical frequency standard.