Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Elsevier eBooks

Quantum Dephasing in Mesoscopic Systems

Y. Imry

Published Jan 1, 1999• 0 citations
Publisher
DOI
10.1016/b978-044450091-5/50041-5

Related papers

Dephasing in Mesoscopic Systems.

Pritiraj Mohanty, Manher Jariwala, R. A. Webb

APS•Mar 1, 1997•0 citations

Dephasing of Quantum Bits by a Quasi-Static Mesoscopic Environment

Jacob M. Taylor, Mikhail D. Lukin

arXiv:quant-ph/0512059•Quantum Information Processing•Aug 28, 2006•34 citations

Controlled Dephasing and Measurement Efficiency via Quantum Dot Detector

Gyong Luck Khym, Youngnae Lee, Kicheon Kang

We study charge detection and controlled dephasing of a mesoscopic system via a quantum dot detector (QDD), where the mesoscopic system and the QDD are capacitively coupled. The QDD is considered to have coherent resonant tunnelling via a single level. It is found that the dephasing rate is proportional to the square of the conductance of the QDD for the Breit-Wigner model, showing that the dephasing is completely different from the shot noise of the detector. The measurement rate, on the other hand, shows a dip near the resonance. Our findings are peculiar especially for a symmetric detector in the following aspect: The dephasing rate is maximum at resonance of the QDD where the detector conductance is insensitive to the charge state of the mesoscopic system. As a result, the efficiency of the detector shows a dip and vanishes at resonance, in contrast to the single-channel symmetric non-resonant detector that has always a maximum efficiency. We find that this difference originates from a very general property of the scattering matrix: The abrupt phase change exists in the scattering amplitudes in the presence of the symmetry, which is insensitive to the detector current but {\em stores} the information of the quantum state of the mesoscopic system.

arXiv:cond-mat/0601535•Journal of the Physical Society of Japan•Jun 8, 2006•10 citations

Dephasing in isolated one-dimensional quantum systems

Jürgen Brickmann, Peter Russegger

Chemical Physics•Jul 1, 1982•9 citations

Charge fluctuations and dephasing in coulomb coupled conductors

Μ. Büttiker

It is shown that the dephasing rate in Coulomb coupled mesoscopic structures is determined by charge relaxation resistances. The charge relaxation resistance together with the capacitance determines the RC-time of the mesoscopic structure and at small frequencies determines the voltage fluctuation spectrum. Self-consistent expressions are presented which give the charge relaxation resistance and consequently the dephasing rate in terms of the diagonal and off-diagonal elements of a generalized Wigner-Smith delay-time matrix. Dephasing rates are discussed both for the equilibrium state and in the transport state in which charge fluctuations are generated by shot noise. A number of different geometries are discussed. This article is to appear in {\it Quantum Mesoscopic Phenomena and Mesoscopic Devices}, edited by I. O. Kulik and R. Ellialtioglu, (Kluwer, unpublished).

arXiv:cond-mat/9911188•Nov 12, 1999•11 citations

Quantum Coherence in Mesoscopic Systems

B. Krämer

NATO ASI series. Series B : Physics•Jan 1, 1991•325 citations
We study charge detection and controlled dephasing of a mesoscopic system via a quantum dot detector (QDD), where the mesoscopic system and the QDD are capacitively coupled. The QDD is considered to have coherent resonant tunnelling via a single level. It is found that the dephasing rate is proportional to the square of the conductance of the QDD for the Breit-Wigner model, showing that the dephasing is completely different from the shot noise of the detector. The measurement rate, on the other hand, shows a dip near the resonance. Our findings are peculiar especially for a symmetric detector in the following aspect: The dephasing rate is maximum at resonance of the QDD where the detector conductance is insensitive to the charge state of the mesoscopic system. As a result, the efficiency of the detector shows a dip and vanishes at resonance, in contrast to the single-channel symmetric non-resonant detector that has always a maximum efficiency. We find that this difference originates from a very general property of the scattering matrix: The abrupt phase change exists in the scattering amplitudes in the presence of the symmetry, which is insensitive to the detector current but {\em stores} the information of the quantum state of the mesoscopic system.
It is shown that the dephasing rate in Coulomb coupled mesoscopic structures is determined by charge relaxation resistances. The charge relaxation resistance together with the capacitance determines the RC-time of the mesoscopic structure and at small frequencies determines the voltage fluctuation spectrum. Self-consistent expressions are presented which give the charge relaxation resistance and consequently the dephasing rate in terms of the diagonal and off-diagonal elements of a generalized Wigner-Smith delay-time matrix. Dephasing rates are discussed both for the equilibrium state and in the transport state in which charge fluctuations are generated by shot noise. A number of different geometries are discussed. This article is to appear in {\it Quantum Mesoscopic Phenomena and Mesoscopic Devices}, edited by I. O. Kulik and R. Ellialtioglu, (Kluwer, unpublished).