Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Series in atomic and molecular physics/Series in atomic molecular physics

Auto-correlation functions

Published Dec 31, 2004• 0 citations
Publisher
DOI
10.1201/9781420033601.ch2

Related papers

Correlation Functions

Peter Millington

Springer theses•Oct 28, 2013•0 citations

Universal relation between the conditional auto-correlation function and the cross-correlation function of biphotons

Teng-Jen Shih, Wei‐Kai Huang, Yi-Min Lin +7 more

We systematically studied the relation between the conditional auto-correlation function (CACF) and cross-correlation function (CCF) of biphotons or pairs of single photons. The biphotons were generated from a heated atomic vapor via the spontaneous four-wave mixing (SFWM) process. In practical usage, one single photon of a pair is utilized as the heralding photon, and another is employed as the heralded photon. Motivated by the data of CACF of the heralded photons versus CCF, we proposed a universal formula to predict the CACF. The derived formula was based on general theory and is also valid for the biphoton generation process of spontaneous parametric down-conversion (SPDC). With the formula, we utilized the experimentally determined parameters to predict CACFs, which can well agree with the measured CACFs. The proposed formula enables one to quantitatively know the CACF of heralded single photons without the measurement of Hanbury-Brown-Twiss-type three-fold coincidence count. This study provides a better understanding of biphoton generation using the SFWM or SPDC process. Our work demonstrates a valuable tool for analyzing a vital property of how the heralded photons are close to Fock-state single photons.

Optics Express•Mar 20, 2024•11 citations

Correlation Functions

Ulrich Hohenester

Graduate texts in physics•Dec 18, 2019•0 citations

Auto-correlation Functions and Quantum Fluctuations of the Transverse Ising Chain by the Quantum Transfer Matrix Method

Inoue, Makoto

The Quantum Transfer Matrix method based on the Suzuki-Trotter formulation is extended to dynamical problems. The auto-correlation functions of the Transverse Ising chain are derived by this method. It is shown that the Trotter-directional correlation function is interpreted as a Matsubara's temperature Green function and that the auto-correlation function is given by analytic continuation of the Green function. We propose the Trotter-directional correlation function is a new measure of the quantum fluctuation and show how it works well as a demonstration.

arXiv:1009.0066•Sep 1, 2010•0 citations

The novel signature code designing and analysis for asvnchronous OCDMA system

Mingde Zhang

Based on Galois theory of definite field, using the square prime sequence, the code function of basic prime code is modified and extended. The auto-correlation and cross corelation of MSPC, which based on square prime sequence, are analyzed in detail. The maximum auto and cross correlation are 2 and 1 respectively. And then, going through reconstructing the prime sequence and code function, a novel signature code, ESPC has been acquired. Compared to basic OPCs derived from linear prime sequence, the maximum value of auto-correlation of ESPC is reduced from p -1 to 1 and cross-correlation is reduced from 2 to 1. the ratio of auto-correlation peak to sideband has largely enhanced, which ensures a better system performance and is more advantageous in signal detection.

Chinese Journal of Quantum Electronics•Jan 1, 2005•0 citations

Correlation Functions

Jurgen Michael Honig, Józef Spałek

Elsevier eBooks•Jan 1, 2018•0 citations
We systematically studied the relation between the conditional auto-correlation function (CACF) and cross-correlation function (CCF) of biphotons or pairs of single photons. The biphotons were generated from a heated atomic vapor via the spontaneous four-wave mixing (SFWM) process. In practical usage, one single photon of a pair is utilized as the heralding photon, and another is employed as the heralded photon. Motivated by the data of CACF of the heralded photons versus CCF, we proposed a universal formula to predict the CACF. The derived formula was based on general theory and is also valid for the biphoton generation process of spontaneous parametric down-conversion (SPDC). With the formula, we utilized the experimentally determined parameters to predict CACFs, which can well agree with the measured CACFs. The proposed formula enables one to quantitatively know the CACF of heralded single photons without the measurement of Hanbury-Brown-Twiss-type three-fold coincidence count. This study provides a better understanding of biphoton generation using the SFWM or SPDC process. Our work demonstrates a valuable tool for analyzing a vital property of how the heralded photons are close to Fock-state single photons.
The Quantum Transfer Matrix method based on the Suzuki-Trotter formulation is extended to dynamical problems. The auto-correlation functions of the Transverse Ising chain are derived by this method. It is shown that the Trotter-directional correlation function is interpreted as a Matsubara's temperature Green function and that the auto-correlation function is given by analytic continuation of the Green function. We propose the Trotter-directional correlation function is a new measure of the quantum fluctuation and show how it works well as a demonstration.
Based on Galois theory of definite field, using the square prime sequence, the code function of basic prime code is modified and extended. The auto-correlation and cross corelation of MSPC, which based on square prime sequence, are analyzed in detail. The maximum auto and cross correlation are 2 and 1 respectively. And then, going through reconstructing the prime sequence and code function, a novel signature code, ESPC has been acquired. Compared to basic OPCs derived from linear prime sequence, the maximum value of auto-correlation of ESPC is reduced from p -1 to 1 and cross-correlation is reduced from 2 to 1. the ratio of auto-correlation peak to sideband has largely enhanced, which ensures a better system performance and is more advantageous in signal detection.