Springer series in optical sciences/SPringer series in optical sciences

Sideband Saturation Spectroscopy with a Frequency-Modulated PbSnTe Diode Laser

Yasuhiro Ohshima, Yoshiyasu Matsumoto, M. Takami, Kozo Kuchitsu

Published Jan 1, 1987• 0 citations
Publisher
DOI
10.1007/978-3-540-47973-4_124

Related papers

Rb saturation spectroscopy with an optically narrowed FM diode laser

G. P. Barwood, Patrick Robert Gill, W. R. C. Rowley

Optics Communications•Jan 1, 1991•5 citations

Frequency-modulation spectroscopy of rubidium atoms with an AlGaAs diode laser

Shunsuke Nakanishi, H. Ariki, Hiroshi Itoh +1 more

Frequency-modulation (FM) spectroscopy has been performed on the D(2) transitions of rubidium atoms with an AlGaAs diode laser at 780 nm. Doppler-broadened hyperfine-structure transitions of (85)Rb and (87)Rb were resolved with no residual amplitude-modulation-induced background signal by modulating the injection current of the laser diode at a low frequency (20-50 MHz) compared with the Doppler width. To obtain Doppler-free spectra, we combined FM spectroscopy with saturation spectroscopy. The results show that the FM spectroscopy technique is sensitive and should be useful for high-resolution spectroscopy, although the resolution was instrument limited and unusual double peaks were observed.

Optics Letters•Nov 1, 1987•10 citations

Laser Saturation Spectroscopy in the Time-Delayed Mode

M. Ducloy, Michael S. Feld

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 1977•3 citations

Laser frequency stabilization and shifting by using modulation transfer spectroscopy

Bing Cheng, Zhaoying Wang, Bin Wu +4 more

The stabilizing and shifting of laser frequency are very important for the interaction between the laser and atoms. The modulation transfer spectroscopy for the 87 Rb atom with D2 line transition F = 2 → F′ = 3 is used for stabilizing and shifting the frequency of the external cavity grating feedback diode laser. The resonant phase modulator with electro—optical effect is used to generate frequency sideband to lock the laser frequency. In the locking scheme, circularly polarized pump- and probe-beams are used. By optimizing the temperature of the vapor, the pump- and probe-beam intensity, the laser linewidth of 280 kHz is obtained. Furthermore, the magnetic field generated by a solenoid is added into the system. Therefore the system can achieve the frequency locking at any point in a range of hundreds of megahertz frequency shifting with very low power loss.

Chinese Physics B•Oct 1, 2014•24 citations

Frequency Modulation Spectroscopy and Modulation Transfer Spectroscopy for Laser Stabilization to Rubidium Atomic Resonances

Jinni Wu, Ningxuan Zheng, Wenhui Li

We make a detailed comparison of frequency modulation spectroscopy (FMS) and modulation transfer spectroscopy (MTS) and of their applications in stabilizing laser frequency. In both FMS and MTS, intensity modulations of probe beam are observed in saturated absorption spectroscopy of 87Rb atoms. However, the two modulation profiles appear different due to their distinct origins. Demodulation gives rise to frequency discrimination spectra, which can serve as error signals for frequency locking. The optimal error signal of FMS has a larger linear slope but also a slanted baseline, in contrast to that of MTS. We apply FMS and MTS to stabilize two 780 nm external cavity diode lasers to D2 lines of 87Rb atoms. We measure laser linewidth and stability using beat notes of two independently locked lasers. A laser linewidth as narrow as 12.9 kHz is achieved in FMS locking, compared to 70.8 kHz in MTS locking. A laser stability at the level of 10−12 is reached in both schemes. Nevertheless, FMS locking offers a better short-term stability, whereas MTS locking yields a smaller long-term drift. Our investigation of FMS and MTS would be valuable for making a choice of these spectroscopy techniques for laser stabilization as well as other relevant applications.

Photonics•Oct 21, 2026•0 citations

Double-Quantum Saturation Spectroscopy with Lasers and rf

E. W. Weber

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 1979•0 citations
Frequency-modulation (FM) spectroscopy has been performed on the D(2) transitions of rubidium atoms with an AlGaAs diode laser at 780 nm. Doppler-broadened hyperfine-structure transitions of (85)Rb and (87)Rb were resolved with no residual amplitude-modulation-induced background signal by modulating the injection current of the laser diode at a low frequency (20-50 MHz) compared with the Doppler width. To obtain Doppler-free spectra, we combined FM spectroscopy with saturation spectroscopy. The results show that the FM spectroscopy technique is sensitive and should be useful for high-resolution spectroscopy, although the resolution was instrument limited and unusual double peaks were observed.
The stabilizing and shifting of laser frequency are very important for the interaction between the laser and atoms. The modulation transfer spectroscopy for the 87 Rb atom with D2 line transition F = 2 → F′ = 3 is used for stabilizing and shifting the frequency of the external cavity grating feedback diode laser. The resonant phase modulator with electro—optical effect is used to generate frequency sideband to lock the laser frequency. In the locking scheme, circularly polarized pump- and probe-beams are used. By optimizing the temperature of the vapor, the pump- and probe-beam intensity, the laser linewidth of 280 kHz is obtained. Furthermore, the magnetic field generated by a solenoid is added into the system. Therefore the system can achieve the frequency locking at any point in a range of hundreds of megahertz frequency shifting with very low power loss.
We make a detailed comparison of frequency modulation spectroscopy (FMS) and modulation transfer spectroscopy (MTS) and of their applications in stabilizing laser frequency. In both FMS and MTS, intensity modulations of probe beam are observed in saturated absorption spectroscopy of 87Rb atoms. However, the two modulation profiles appear different due to their distinct origins. Demodulation gives rise to frequency discrimination spectra, which can serve as error signals for frequency locking. The optimal error signal of FMS has a larger linear slope but also a slanted baseline, in contrast to that of MTS. We apply FMS and MTS to stabilize two 780 nm external cavity diode lasers to D2 lines of 87Rb atoms. We measure laser linewidth and stability using beat notes of two independently locked lasers. A laser linewidth as narrow as 12.9 kHz is achieved in FMS locking, compared to 70.8 kHz in MTS locking. A laser stability at the level of 10−12 is reached in both schemes. Nevertheless, FMS locking offers a better short-term stability, whereas MTS locking yields a smaller long-term drift. Our investigation of FMS and MTS would be valuable for making a choice of these spectroscopy techniques for laser stabilization as well as other relevant applications.