Physical Review Letters

An interferometer for atoms

David W. Keith, Christopher R. Ekstrom, Q. A. Turchette, David E. Pritchard

Published May 27, 1991• 597 citations
Publisher

Abstract

We have demonstrated an interferometer for atoms. A three-grating geometry is used, in which the interfering beams are distinctly separated in both position and momentum. We used a highly collimated beam of sodium atoms with a de Broglie wavelength of 16 pm and high-quality 0.4-\ensuremath{\mu}m-period free-standing gratings which we fabricated using a novel method. The interference signal is 70 counts/s, which allows us to determine the phase to 0.1 rad in 1 min. Applications of atom interferometers are briefly discussed.

DOI
10.1103/physrevlett.66.2693

Related papers

Atom interferometry

David E. Pritchard, Christopher R. Ekstrom, Jörg Schmiedmayer +2 more

We have constructed an atom interferometer using three 200 nm period transmission gratings. The two interfering portions of each atom’s wave pass on opposite sides of a stretched metal foil. A fringe amplitude of up to 900 cps is observed, which allows us to determine the phase to 15 milliradians in 1 minute. By applying different interactions to the two sides of the interferometer, we have determined the electric polarizability of the ground state of sodium, the coherence length of our beam, and the differential phase shifts and coherences of the different Zeeman ground states in a magnetic field. Some future prospects of separated beam experiments are discussed.

AIP conference proceedings•Jan 1, 1993•0 citations

Atom Interferometry Progress

David E. Pritchard, Christopher R. Ekstrom, David W. Keith +2 more

Abstract : An atom interferometer is constructed in which the atom waves are physically separated prior to being recombined. Fabricated transmission gratings are used as optical elements for the matter waves. Atom interferometers should be useful in studies of atomic properties, tests of basic quantum physics, for metrology, as rotation sensors, and perhaps ultimately as devices to make ultra- small structures using atom holograms. During the last year our atom interferometer has evolved from a rough plan to an essentially complete device. At present all the major components of the interferometer have been built, and tested at least once. The system will be given its first real try in the next year. Our interferometer consists of three 0.2 microns - period diffraction gratings equally spaced approx. 0.65 m apart in our atomic beam machine. The maximum separation of the beams will be approx. 60 microns. The first two gratings separate and redirect the atomic beam forming a standing wave interference pattern in the atomic flux at the third grating, which acts like a mask to sample this pattern. A principle technical obstacle is the mechanical vibrations of our machine which will blur the interference pattern.

mit•Apr 19, 1990•0 citations

Experiments with a separated-beam atom interferometer

David E. Pritchard, Christopher R. Ekstrom, Jörg Schmiedmayer +2 more

Three 0.2 micron period diffraction gratings were combined to realize an atom interferometer1 in which the interfering beams are distinctly separated in both position and momentum. A 10 cm long foil 10 microns thick was positioned symmetrically between two side electrodes, so that the atom wave in the two sides of the interferometer went on opposite sides of it. The fringe amplitude was 820 cps, which allows us to determine the phase to 15 milliradians in 1 minute.2

Annual Meeting Optical Society of America•Jan 1, 1993•6 citations

Diffraction of Atoms by a Transmission Grating

David W. Keith, Mark L. Schattenburg, Henry I. Smith +1 more

We have demonstrated a novel diffraction grating for atoms. A collimated beam of sodium atoms with a de Broglie wavelength of 17 pm was diffracted by transmission through an array of slits with a spatial period of 0.2 \ensuremath{\mu}m formed in a gold membrane. This is the first reported diffraction of atoms by a fabricated periodic structure. Our transmission grating for atoms can divide or recombine an atomic beam coherently, and may provide the easiest route to the realization of an atom wave interferometer.

Physical Review Letters•Oct 3, 1988•197 citations

Measuring Atomic Properties with an Atom Interferometer

Tony Roberts

Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.

•Jan 1, 2002•2 citations

Atom Interferometer Based on Bragg Scattering from Standing Light Waves

David M. Giltner, Roger W. McGowan, S. A. Lee

We have constructed an atom interferometer by Bragg deflecting a collimated beam of metastable neon atoms from three parallel standing waves. Interference fringes have been observed using atoms Bragg scattered at up to the third order, giving a maximum of $6\ensuremath{\Elzxh}k$ transverse momentum difference between the two arms of the interferometer. In the first order case we have achieved a fringe contrast of 62% and a peak to peak signal of 1700 atoms/s. We believe this to be the highest fringe contrast that has been achieved in atom interferometers.

Physical Review Letters•Oct 2, 1995•265 citations
We have demonstrated an interferometer for atoms. A three-grating geometry is used, in which the interfering beams are distinctly separated in both position and momentum. We used a highly collimated beam of sodium atoms with a de Broglie wavelength of 16 pm and high-quality 0.4-\ensuremath{\mu}m-period free-standing gratings which we fabricated using a novel method. The interference signal is 70 counts/s, which allows us to determine the phase to 0.1 rad in 1 min. Applications of atom interferometers are briefly discussed.
We have constructed an atom interferometer using three 200 nm period transmission gratings. The two interfering portions of each atom’s wave pass on opposite sides of a stretched metal foil. A fringe amplitude of up to 900 cps is observed, which allows us to determine the phase to 15 milliradians in 1 minute. By applying different interactions to the two sides of the interferometer, we have determined the electric polarizability of the ground state of sodium, the coherence length of our beam, and the differential phase shifts and coherences of the different Zeeman ground states in a magnetic field. Some future prospects of separated beam experiments are discussed.
Abstract : An atom interferometer is constructed in which the atom waves are physically separated prior to being recombined. Fabricated transmission gratings are used as optical elements for the matter waves. Atom interferometers should be useful in studies of atomic properties, tests of basic quantum physics, for metrology, as rotation sensors, and perhaps ultimately as devices to make ultra- small structures using atom holograms. During the last year our atom interferometer has evolved from a rough plan to an essentially complete device. At present all the major components of the interferometer have been built, and tested at least once. The system will be given its first real try in the next year. Our interferometer consists of three 0.2 microns - period diffraction gratings equally spaced approx. 0.65 m apart in our atomic beam machine. The maximum separation of the beams will be approx. 60 microns. The first two gratings separate and redirect the atomic beam forming a standing wave interference pattern in the atomic flux at the third grating, which acts like a mask to sample this pattern. A principle technical obstacle is the mechanical vibrations of our machine which will blur the interference pattern.
We have demonstrated a novel diffraction grating for atoms. A collimated beam of sodium atoms with a de Broglie wavelength of 17 pm was diffracted by transmission through an array of slits with a spatial period of 0.2 \ensuremath{\mu}m formed in a gold membrane. This is the first reported diffraction of atoms by a fabricated periodic structure. Our transmission grating for atoms can divide or recombine an atomic beam coherently, and may provide the easiest route to the realization of an atom wave interferometer.
Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.
We have constructed an atom interferometer by Bragg deflecting a collimated beam of metastable neon atoms from three parallel standing waves. Interference fringes have been observed using atoms Bragg scattered at up to the third order, giving a maximum of $6\ensuremath{\Elzxh}k$ transverse momentum difference between the two arms of the interferometer. In the first order case we have achieved a fringe contrast of 62% and a peak to peak signal of 1700 atoms/s. We believe this to be the highest fringe contrast that has been achieved in atom interferometers.