Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

A High Sensitive Atomic Co-magnetometer for Rotation Rate Measurement Based on K-Rb-21Ne

Yao Chen, Sheng Zou, Wei Quan, Yan Lü, Ming Ding, Jiancheng Fang

Published May 27, 2016• 0 citations
OpenAlex

Related papers

Rotation Measurement with a K-Rb- 21 Ne Atomic Spin Co-magnetometer Gyroscope

Yao Chen, Sheng Zou, Lihong Duan +1 more

Bulletin of the American Physical Society•Jun 4, 2014•0 citations

Spin exchange broadening of magnetic resonance lines in a high-sensitivity rotating K-Rb-21Ne co-magnetometer

Yao Chen, Wei Quan, Sheng Zou +6 more

Abstract Atomic co-magnetometers can be utilized for high-precision angular velocity sensing or fundamental physics tests. The sensitivity of a co-magnetometer determines the angle random walk of an angular velocity sensor and the detection limit for a fundamental physics test. A high-sensitivity K-Rb-21Ne co-magnetometer, which is utilized for angular velocity sensing, is presented in this paper. A new type of spin relaxation of Rb atom spins, which can broaden the zero-field magnetic resonance lines of the co-magnetometer, is discovered. Further studies show that the spin relaxation of Rb atoms is caused by a high Rb electron magnetization field. With this discovery, the total relaxation rate of Rb atoms is optimized to improve the sensitivity of the co-magnetometer. Moreover, its sensitivity is optimized by suppressing various noises. Especially, to suppress laser-related noises, the co-magnetometer is designed such that the sensitive axis of the co-magnetometer can be fixed to the direction in which the projection input of the earth’s rotation is 0. This is called a rotating co-magnetometer. A magnetic field sensitivity of 1.0 fT/Hz−1/2@5 Hz, which is equal to an angular velocity sensitivity of 2.1 × 10−8 rad s−1 Hz−1/2@5 Hz, is demonstrated using a spherical vapour cell with a diameter of 14 mm.

Scientific Reports•Nov 10, 2016•73 citations

Development of a compact atomic co-magnetometer

Georgios Vasilakis, Thomas W. Kornack, R. Ghosh +2 more

Bulletin of the American Physical Society•May 19, 2006•0 citations

The polarization and the fundamental sensitivity of $^{39}$K ($^{133}$Cs)-$^{85}$Rb-$^{21}$Ne co-magnetometer

Jianhua Liu, Dong-Yang Jing, Lin Zhuang +3 more

We have studied the polarization of the 85Rb and the fundamental sensitivity of two types of hybrid optical pumping spin exchange relaxation free (SERF) co-magnetometers based on 39K-85Rb-21Ne and 133Cs-85Rb-21Ne with taking the wall relaxation rate into account,which has a big effect on the polarization and fundamental sensitivity,but it is often neglected in the experiments,respectively.The polarization of the 85Rb varies with the thirteen systemic parameters: the number density of buffer gas 21Ne and quench gas N2,frequency rate of pump beam,cell temperature,the photon number flux,mole fraction of 85Rb,cell effective radius,pump beam spot radius,power density of pump beam,input rotation velocity in the x and y direction,external magnetic field in the y and z direction,respectively.The number density of the 21Ne,photon number flux,pump beam spot radius and frequency rate will affect the polarization of the 85Rb greatly by affecting the the pumping rate of pump beam,a magnetic field produced by 85Rb atom spins and experienced by the 21Ne spins.We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF co-magnetometers due to shot-noise,where the fundamental sensitivity varies with the twelve systemic parameters: the number density of buffer gas and quench gas,frequency rate of pump beam,photon number flux,mole fraction of 85Rb,cell effective radius,pump beam spot radius,power density of pump beam,external magnetic field,measurement volume,cell temperature and measurement time.The highest fundamental sensitivity $7.5878\times10^{-11}$ $rad/s/Hz^{1/2}$ of 133Cs-85Rb-21Ne co-magnetometer is higher than the ultimate theoretical sensitivity $2\times10^{-10}$ $rad/s/Hz^{1/2}$ of K-21Ne co-magnetometer.The fundamental sensitivity limit of the hybrid optical pumping SERF co-magnetometers is superior to $3.7334\times10^{-12}$ $rad/s/Hz^{1/2}$.

•Nov 5, 2018•0 citations

Closed-loop atomic spin polarization detection based on EOAM modulation in K-Rb-21Ne co-magnetometers

Shimiao Fan, Wenfeng Fan, Qi Yuan +4 more

We propose a high-sensitivity spin polarization detection scheme based on optical amplitude modulation in atomic co-magnetometers, which is different from the traditional configuration.A linearly polarized laser with intensity modulation interacts with electron spins, generating optical rotation angles.Through differential amplification and demodulation, atomic spin polarization information is extracted with high precision.The effectiveness of the proposed method is verified by applying external perturbations during testing.Compared to traditional detection methods, the proposed approach effectively enhances inertial measurement sensitivity.Specifically, at 1 Hz, the measurement sensitivity has improved from 9.7 × 10 -6 to 3.25 × 10 -6 deg/(s Hz 1/2 ).Furthermore, the proposed scheme is easily integrable and conducive to future research on miniaturizing co-magnetometers and can also be applied to many other related fields.

Chinese Optics Letters•Jan 1, 2024•4 citations

A Rb-magnetometer for a wide range and high sensitivity

Werner D. Farr, Ernst Wilhelm Otten

Applied Physics A•May 1, 1974•26 citations
Abstract Atomic co-magnetometers can be utilized for high-precision angular velocity sensing or fundamental physics tests. The sensitivity of a co-magnetometer determines the angle random walk of an angular velocity sensor and the detection limit for a fundamental physics test. A high-sensitivity K-Rb-21Ne co-magnetometer, which is utilized for angular velocity sensing, is presented in this paper. A new type of spin relaxation of Rb atom spins, which can broaden the zero-field magnetic resonance lines of the co-magnetometer, is discovered. Further studies show that the spin relaxation of Rb atoms is caused by a high Rb electron magnetization field. With this discovery, the total relaxation rate of Rb atoms is optimized to improve the sensitivity of the co-magnetometer. Moreover, its sensitivity is optimized by suppressing various noises. Especially, to suppress laser-related noises, the co-magnetometer is designed such that the sensitive axis of the co-magnetometer can be fixed to the direction in which the projection input of the earth’s rotation is 0. This is called a rotating co-magnetometer. A magnetic field sensitivity of 1.0 fT/Hz−1/2@5 Hz, which is equal to an angular velocity sensitivity of 2.1 × 10−8 rad s−1 Hz−1/2@5 Hz, is demonstrated using a spherical vapour cell with a diameter of 14 mm.
The polarization and the fundamental sensitivity of 39^{39}39K (133^{133}133Cs)-85^{85}85Rb-21^{21}21Ne co-magnetometer
We have studied the polarization of the 85Rb and the fundamental sensitivity of two types of hybrid optical pumping spin exchange relaxation free (SERF) co-magnetometers based on 39K-85Rb-21Ne and 133Cs-85Rb-21Ne with taking the wall relaxation rate into account,which has a big effect on the polarization and fundamental sensitivity,but it is often neglected in the experiments,respectively.The polarization of the 85Rb varies with the thirteen systemic parameters: the number density of buffer gas 21Ne and quench gas N2,frequency rate of pump beam,cell temperature,the photon number flux,mole fraction of 85Rb,cell effective radius,pump beam spot radius,power density of pump beam,input rotation velocity in the x and y direction,external magnetic field in the y and z direction,respectively.The number density of the 21Ne,photon number flux,pump beam spot radius and frequency rate will affect the polarization of the 85Rb greatly by affecting the the pumping rate of pump beam,a magnetic field produced by 85Rb atom spins and experienced by the 21Ne spins.We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF co-magnetometers due to shot-noise,where the fundamental sensitivity varies with the twelve systemic parameters: the number density of buffer gas and quench gas,frequency rate of pump beam,photon number flux,mole fraction of 85Rb,cell effective radius,pump beam spot radius,power density of pump beam,external magnetic field,measurement volume,cell temperature and measurement time.The highest fundamental sensitivity 7.5878×10−117.5878\times10^{-11}7.5878×10−11 rad/s/Hz1/2rad/s/Hz^{1/2}rad/s/Hz1/2 of 133Cs-85Rb-21Ne co-magnetometer is higher than the ultimate theoretical sensitivity 2×10−102\times10^{-10}2×10−10 rad/s/Hz1/2rad/s/Hz^{1/2}rad/s/Hz1/2 of K-21Ne co-magnetometer.The fundamental sensitivity limit of the hybrid optical pumping SERF co-magnetometers is superior to 3.7334×10−123.7334\times10^{-12}3.7334×10−12 rad/s/Hz1/2rad/s/Hz^{1/2}rad/s/Hz1/2.
We propose a high-sensitivity spin polarization detection scheme based on optical amplitude modulation in atomic co-magnetometers, which is different from the traditional configuration.A linearly polarized laser with intensity modulation interacts with electron spins, generating optical rotation angles.Through differential amplification and demodulation, atomic spin polarization information is extracted with high precision.The effectiveness of the proposed method is verified by applying external perturbations during testing.Compared to traditional detection methods, the proposed approach effectively enhances inertial measurement sensitivity.Specifically, at 1 Hz, the measurement sensitivity has improved from 9.7 × 10 -6 to 3.25 × 10 -6 deg/(s Hz 1/2 ).Furthermore, the proposed scheme is easily integrable and conducive to future research on miniaturizing co-magnetometers and can also be applied to many other related fields.