Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics and Laser Science Conference

Noise reduction in micromasers

Nicim Zagury, E. S. Guerra, Antonio Zelaquett Khoury, L. Davidovich

Published May 12, 1991• 0 citations
OpenAlex

Abstract

The field statistics in micromasers can be quite different from those of macroscopic lasers and masers.1,2 In particular, the field produced in these devices is expected to be sub-Poissonian for some range of the parameters, and this has been experimentally observed.3 On the other hand, evidence for the role of the pumping statistics in lasers and masers has recently been produced.4-8

Related papers

Role of pumping statistics in micromasers

E. S. Guerra, Antonio Zelaquett Khoury, L. Davidovich +1 more

We show that regularization of pumping leads to large photon-number noise reduction in one- and two-photon micromasers, and is much more important than in macroscopic lasers and masers. Our calculations are based on a step-by-step microscopic approach and are compared to results obtained from a pumping-statistics-dependent master equation, which is shown not to be entirely reliable in the micromaser case. Although noise reduction and the discrepancies betwen the two approaches are more important for monokinetic beams, they are still relevant when a 10% velocity dispersion is allowed.

Physical Review A•Dec 1, 1991•29 citations

Effect of pump statistics on the micromaser

János A. Bergou, Peter G. Kalman

We present a theory of the micromaser including the effect of the arrival-time statistics of the active atoms in the theoretical treatments. Our starting point is an approach that explicitly incorporates the effect of pump statistics into the dynamical description of lasers and masers. We show that the application of standard laser theory to the micromaser is tantamount to the tacit assumption of Poissonian arrival-time statistics. Hence standard laser theory and the theory of the micromaser are, in general, not equivalent, but the latter contains the former, as a limiting case, for completely random arrival times. We show, as an application, that the steady-state value of the average photon number (first moment) is essentially unaffected by the pump statistics since it depends only on the flux of active atoms (average number of atoms entering the cavity per unit time) provided the flux is constant. The intensity fluctuations (second moment), however, exhibit a stronger dependence on the pump statistics. In particular, for sub-Poissonian pump statistics the sub-Poissonian character of the field is enhanced.

Physical Review A•Apr 1, 1991•9 citations

Role of pumping statistics in maser and laser dynamics: Density-matrix approach

János A. Bergou, L. Davidovich, Miguel Orszag +3 more

We discuss in detail the influence that the statistical properties of the pump source have on maser and laser dynamics. We derive a general master equation for the radiation field that is valid for a wide range of different pump mechanisms. If the pump noise is eliminated, we find that the photon number noise in a micromaser and a laser can be significantly reduced below the shot-noise level. In contrast, the phase fluctuations for both maser and laser are unaffected by the noise contribution of the pump.

Physical Review A•Nov 1, 1989•100 citations

Observation of sub-Poissonian photon statistics in a micromaser

Gerhard Rempe, Ferdinand Schmidt‐Kaler, HERBERT WALTHER

We describe the first investigation of the nonclassical radiation field of a micromaser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor 3\ifmmode\times\else\texttimes\fi{}${10}^{10}$. Velocity-selected Rydberg atoms pump the maser. The photon statistics in the cavity are measured via the statistics of the atoms leaving the cavity in the lower maser level. Taking into account a detection efficiency of 10%, their fluctuations are reduced up to 40% below the Poisson level. This corresponds to photon-number fluctuations in the cavity of up to 70% below the vacuum-state limit.

Physical Review Letters•Jun 4, 1990•565 citations

Effects of regular pumping on photon statistics in masers and lasers

Shi-Yao Zhu, Muhammad Suhail Zubairy, Chang Su +1 more

In laser systems, regular pumping always reduces the photon noise. In micromaser systems, however, regular pumping may lead to photon noise reduction as well as photon noise increase depending on the operation conditions. The effect of higher-order terms in the expansion of ln(1+pu) with respect to the pumping regularity parameter p is discussed. These terms have a significant effect on the photon statistics in micromaser systems. Their effect in laser systems is quite small compared with the second order and can be neglected.

Physical Review A•Jan 1, 1992•13 citations

Sub-Poissonian atomic statistics in a micromaser

Gerhard Rempe, HERBERT WALTHER

It is shown analytically that under certain experimental conditions the steady-state photon statistics of a micromaser field are directly connected to the fluctuation in number of the atoms in transition from the upper to the lower maser level under the influence of the maser field. The analytical results are compared to the results of a computer simulation of the maser process.

Physical Review A•Aug 1, 1990•134 citations
The field statistics in micromasers can be quite different from those of macroscopic lasers and masers.1,2 In particular, the field produced in these devices is expected to be sub-Poissonian for some range of the parameters, and this has been experimentally observed.3 On the other hand, evidence for the role of the pumping statistics in lasers and masers has recently been produced.4-8
We show that regularization of pumping leads to large photon-number noise reduction in one- and two-photon micromasers, and is much more important than in macroscopic lasers and masers. Our calculations are based on a step-by-step microscopic approach and are compared to results obtained from a pumping-statistics-dependent master equation, which is shown not to be entirely reliable in the micromaser case. Although noise reduction and the discrepancies betwen the two approaches are more important for monokinetic beams, they are still relevant when a 10% velocity dispersion is allowed.
We present a theory of the micromaser including the effect of the arrival-time statistics of the active atoms in the theoretical treatments. Our starting point is an approach that explicitly incorporates the effect of pump statistics into the dynamical description of lasers and masers. We show that the application of standard laser theory to the micromaser is tantamount to the tacit assumption of Poissonian arrival-time statistics. Hence standard laser theory and the theory of the micromaser are, in general, not equivalent, but the latter contains the former, as a limiting case, for completely random arrival times. We show, as an application, that the steady-state value of the average photon number (first moment) is essentially unaffected by the pump statistics since it depends only on the flux of active atoms (average number of atoms entering the cavity per unit time) provided the flux is constant. The intensity fluctuations (second moment), however, exhibit a stronger dependence on the pump statistics. In particular, for sub-Poissonian pump statistics the sub-Poissonian character of the field is enhanced.
We discuss in detail the influence that the statistical properties of the pump source have on maser and laser dynamics. We derive a general master equation for the radiation field that is valid for a wide range of different pump mechanisms. If the pump noise is eliminated, we find that the photon number noise in a micromaser and a laser can be significantly reduced below the shot-noise level. In contrast, the phase fluctuations for both maser and laser are unaffected by the noise contribution of the pump.
We describe the first investigation of the nonclassical radiation field of a micromaser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor 3\ifmmode\times\else\texttimes\fi{}1010{10}^{10}1010. Velocity-selected Rydberg atoms pump the maser. The photon statistics in the cavity are measured via the statistics of the atoms leaving the cavity in the lower maser level. Taking into account a detection efficiency of 10%, their fluctuations are reduced up to 40% below the Poisson level. This corresponds to photon-number fluctuations in the cavity of up to 70% below the vacuum-state limit.
In laser systems, regular pumping always reduces the photon noise. In micromaser systems, however, regular pumping may lead to photon noise reduction as well as photon noise increase depending on the operation conditions. The effect of higher-order terms in the expansion of ln(1+pu) with respect to the pumping regularity parameter p is discussed. These terms have a significant effect on the photon statistics in micromaser systems. Their effect in laser systems is quite small compared with the second order and can be neglected.