Journal of Applied Optics

STUDY ON THE ABSOLUTE MEASUREMENT METHOD OF INFRARED SPECTRAL RADIANCE

Li Sun

Published Jan 1, 1999• 0 citations
OpenAlex

Abstract

The generation mechanism of spontaneous parametric down conversion(SPDC)biphoton field is discussed theoretically.The correlated photons produced in the SPDC process have been used in the absolute measurement of infrared spectral radiance.The measurement principle and method are introduced.

Related papers

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN CONVERSION BIPHOTON FIELD

Sun Li

A new method of absolute calibration of photodetector′s sensitivity based on spontaneous parametric down conversion (SPDC) biphoton field is discussed.The process of SPDC is studied theoretically.An experimental system has been set up. The sensitivity of a photon counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Journal of Applied Optics•Jan 1, 1999•0 citations

Investigation of absolute measurement in quantum efficiency of photoelectric detectors by means of correlated photons

Yu Feng, Xiaobing Zheng, Yanli Qiao +1 more

There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 23, 2006•0 citations

Absolute measurement of photodetector quantum efficiency based on spontaneous parametric down-conversion biphoton field

Liqun Sun, Yanpeng Zhang, Tiantong Tang +2 more

A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 4, 1999•0 citations

ABSOLUTE CALIBRATION OF PHOTODETECTORS BASED ON SPONTANEOUS PARAMETRIC DOWN-CONVERSION BIPHOTON FIELD

L. J. Sun, Zhiyu Yang

A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.

Acta Physica Sinica•Jan 1, 2000•0 citations

Study on generation mechanism and state function of spontaneous parametric down-conversion light field

Xinli Ma

Based on analyzing the interaction of pumping photons and a nonlinear crystal with no center of symmetry, an explanation about the generation mechanism of spontaneous parametric down-conversion (SPDC) light field was put forward. Then state function of SPDC biphoton light field was derived and a probability explanation was given.

Chinese Journal of Quantum Electronics•Jan 1, 2004•0 citations

Optimization of AgGaS 2 crystal orientation for quantum standardless calibration of the spectral radiance

A V Veselovskiy, Anna V. Paterova, G. Kh. Kitaeva

We develop the collinear optical scheme for absolute calibration of the spectral radiance of IR sources using quantum properties of spontaneous parametric down-conversion (SPDC) effect. Characteristics of spatial resolution and the spectral range of measurements attainable with AgGaS2crystal pumped at 785 nm are discussed. Results of calculations of the angle between the crystal optical axis and the pump wave vector, required to achieve collinear phase matching at target IR frequencies, are presented and verified experimentally by recording the frequency-angular distribution of SPDC signal in the crystal sample cut for the radiance measurement of external radiation at the wavelength of 6 μm.

International Conference Laser Optics (ICLO)•Jun 1, 2026•0 citations
There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.
A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.
A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down\|conversion(SPDC) biphoton field is described.The process of SPDC is studied theoretically.The single photon detection probability and two\|photon coincidence probability are derived and the calibration principle for photodetectors is explained.An experimental system has been set up.The sensitivity of a photon\|counting photomultiplier tube was measured,and the results were compared with those obtained using conventional method.
We develop the collinear optical scheme for absolute calibration of the spectral radiance of IR sources using quantum properties of spontaneous parametric down-conversion (SPDC) effect. Characteristics of spatial resolution and the spectral range of measurements attainable with AgGaS2crystal pumped at 785 nm are discussed. Results of calculations of the angle between the crystal optical axis and the pump wave vector, required to achieve collinear phase matching at target IR frequencies, are presented and verified experimentally by recording the frequency-angular distribution of SPDC signal in the crystal sample cut for the radiance measurement of external radiation at the wavelength of 6 μm.