Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Optoelectronic Technology

Laser Pumping Cs Atom High-Resolution Magnetometer of Theory Research Based on Hyperfine Structure

Caiping Zheng

Published Jan 1, 2010• 0 citations
OpenAlex

Abstract

Laser pumping magnetometers using alkali vapors as sensing medium can reach very high sensitivities in magnetic fields covering the range from the earth magnetic field to biological magnetic fields. In this paper, the theoretical analysis and system design of laser pumping cesium magnetometer, cesium atomic energy level formed hyperfine structure with the I-J coupling are discussed. The hyperfine structure is further split into Zeeman sublevels for the effects of magnetic field. The electrons transition is made by using laser pumping and RF magnetic field in the hyperfine structure. The results of magne-to-optical double resonance is obtained. The accurate value of the external magnetic field could be measured by the resonant frequency.

Related papers

Laser pumping magnetic resonance of theory research based on coherent population trapping

Zhang Yang, Kang Chong, Qingtao Wang +3 more

In the Λ three-level system, we will make use of semi-classical density matrix method to analyze cesium (Cs) hyperfine structure of coherent population trapping (CPT) phenomenon. Coherent population trapping has been widely used in electromagnetically induced transparency, non-inversion laser, optical storage and ultra-slow speed of light fields, then strong-coupling light and weak detecting light form coherent laser light to change the hyperfine structure energy levels of particles number distribution, which impacts on laser pumping magnetic resonance. In this paper, we will discuss the theoretical analysis and system design of laser pumping cesium magnetometer, cesium atomic energy level formed hyperfine structure with the I-J coupling, the hyperfine structure has been further split into Zeeman sublevels for the effects of magnetic field. To use laser pump and RF magnetic field make electrons transition in the Zeeman sublevels to produce the results of magneto-optical double resonance and on this basis we analyze the influence of laser pumping magnetic resonance based on coherent population trapping.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 13, 2010•0 citations

Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Journal of Optoelectronics·laser•Jan 1, 2015•0 citations

Effect of the geomagnetic field on the resonance spectral lines of the Cs magnetometer

LI Qingmen

In order to study the effect of the geomagnetic field on cesium magnetometer sensitivity,the Breit-Rabi equation is used to analyze the Zeeman splitting of the F g = 4 level of Cs atoms. The emphasis is on the analysis of the nonlinear Zeeman effect on the resonant hyperfine spectrum of the all-optical atomic magnetometer in the geomagnetic field which is about 0.05 mT. The results show that the effect would cause the line-width to increase from 20 Hz to 53 Hz,and the amplitude to decrease by relatively 50%. If any accessional noise is not taken into account,our cesium magnetometer sensitivity will deteriorate from 0.3 pT / Hz1 /2to 1.6 pT / Hz1 /2. That showed a technical bottleneck of improving atomic magnetometer sensitivity in the geomagnetic field. A new technique of pumping from F g = 4 to F e = 4 is proposed to break through this bottleneck.

Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University•Jan 1, 2013•0 citations

On the efficiency of laser pumping of hyperfine structure sublevels of Rubidium-87 and Cesium-133 atoms

A. I. Magunov, Vitalii G Pal'chikov

The evolution of the hyperfine structure magnetic sublevel populations of 87 Rb and 133 Cs atoms in resonant linearly polarized laser fields is theoretically analyzed. Analytical expressions are obtained for stationary populations of the magnetic sublevels of the ground state 5 2 S 1/2 F g = 1, F f = 2 in 87 Rb and 6 2 S 1/2 F g = 3, F f = 4 in 133 Cs under optical pumping at the F g ↔ F e = F g and F f ↔ F e = F f transitions of the D 2 lines ( n 2 S 1/2 n 2 P 3/2 ) versus the initial populations. The characteristic population stabilization time are obtained by numerical solution for the density matrix equations, depending on the intensity of the laser fields and the detuning of the optical resonance. It is shown that the alternation of the polarization direction of the laser field at the transition F f ↔ F e = F f almost completely transfers atoms to the lower sublevel of the "clock" M1 transition F g M = 0 ↔ F f M = 0 in rubidium and cesium frequency standards, which proportionally increases the signal of the recording system.

Journal of Physics Conference Series•Sep 1, 2021•0 citations

Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

V. Schultze, Theo Scholtes, R.P.J. IJsselsteijn +1 more

Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.

Journal of the Optical Society of America B•Apr 2, 2015•21 citations

Double magnetic resonance in the hyperfine structure of optically oriented alkali atoms with laser pumping

A A Baranov, Ермак Сергей Викторович, E. A. Sagitov +1 more

The paper is devoted to the investigation of mutual influence of low-frequency and microwave resonances in 87 Rb vapor cell magnetometers system with laser pumping. One of the magnetometers was based on a low-frequency spin generator principle, while the second one was built as passive microwave spectrometer with a resonance frequency lock loop. The paper analyzes the frequency shifts in the low-frequency and microwave channels of the tandem of magnetometers associated with the simultaneous action of the resonant radio fields on the alkali atoms. Such effect is manifested in the frequency shifts of the spin generator for fixed changes in the amplitude of the microwave field.

Journal of Physics Conference Series•Jun 1, 2018•1 citation
Laser pumping magnetometers using alkali vapors as sensing medium can reach very high sensitivities in magnetic fields covering the range from the earth magnetic field to biological magnetic fields. In this paper, the theoretical analysis and system design of laser pumping cesium magnetometer, cesium atomic energy level formed hyperfine structure with the I-J coupling are discussed. The hyperfine structure is further split into Zeeman sublevels for the effects of magnetic field. The electrons transition is made by using laser pumping and RF magnetic field in the hyperfine structure. The results of magne-to-optical double resonance is obtained. The accurate value of the external magnetic field could be measured by the resonant frequency.
In the Λ three-level system, we will make use of semi-classical density matrix method to analyze cesium (Cs) hyperfine structure of coherent population trapping (CPT) phenomenon. Coherent population trapping has been widely used in electromagnetically induced transparency, non-inversion laser, optical storage and ultra-slow speed of light fields, then strong-coupling light and weak detecting light form coherent laser light to change the hyperfine structure energy levels of particles number distribution, which impacts on laser pumping magnetic resonance. In this paper, we will discuss the theoretical analysis and system design of laser pumping cesium magnetometer, cesium atomic energy level formed hyperfine structure with the I-J coupling, the hyperfine structure has been further split into Zeeman sublevels for the effects of magnetic field. To use laser pump and RF magnetic field make electrons transition in the Zeeman sublevels to produce the results of magneto-optical double resonance and on this basis we analyze the influence of laser pumping magnetic resonance based on coherent population trapping.
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
In order to study the effect of the geomagnetic field on cesium magnetometer sensitivity,the Breit-Rabi equation is used to analyze the Zeeman splitting of the F g = 4 level of Cs atoms. The emphasis is on the analysis of the nonlinear Zeeman effect on the resonant hyperfine spectrum of the all-optical atomic magnetometer in the geomagnetic field which is about 0.05 mT. The results show that the effect would cause the line-width to increase from 20 Hz to 53 Hz,and the amplitude to decrease by relatively 50%. If any accessional noise is not taken into account,our cesium magnetometer sensitivity will deteriorate from 0.3 pT / Hz1 /2to 1.6 pT / Hz1 /2. That showed a technical bottleneck of improving atomic magnetometer sensitivity in the geomagnetic field. A new technique of pumping from F g = 4 to F e = 4 is proposed to break through this bottleneck.
The evolution of the hyperfine structure magnetic sublevel populations of 87 Rb and 133 Cs atoms in resonant linearly polarized laser fields is theoretically analyzed. Analytical expressions are obtained for stationary populations of the magnetic sublevels of the ground state 5 2 S 1/2 F g = 1, F f = 2 in 87 Rb and 6 2 S 1/2 F g = 3, F f = 4 in 133 Cs under optical pumping at the F g ↔ F e = F g and F f ↔ F e = F f transitions of the D 2 lines ( n 2 S 1/2 n 2 P 3/2 ) versus the initial populations. The characteristic population stabilization time are obtained by numerical solution for the density matrix equations, depending on the intensity of the laser fields and the detuning of the optical resonance. It is shown that the alternation of the polarization direction of the laser field at the transition F f ↔ F e = F f almost completely transfers atoms to the lower sublevel of the "clock" M1 transition F g M = 0 ↔ F f M = 0 in rubidium and cesium frequency standards, which proportionally increases the signal of the recording system.
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.
The paper is devoted to the investigation of mutual influence of low-frequency and microwave resonances in 87 Rb vapor cell magnetometers system with laser pumping. One of the magnetometers was based on a low-frequency spin generator principle, while the second one was built as passive microwave spectrometer with a resonance frequency lock loop. The paper analyzes the frequency shifts in the low-frequency and microwave channels of the tandem of magnetometers associated with the simultaneous action of the resonant radio fields on the alkali atoms. Such effect is manifested in the frequency shifts of the spin generator for fixed changes in the amplitude of the microwave field.