Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Zhuzhou Teachers College

Realization of Deutsh-Jozsa Algorithm in Cavity QED

Tan Jia

Published Jan 1, 2007• 0 citations
OpenAlex

Abstract

A practical protocol is proposed for realizing Deutsh-Jozsa algorithm in cavity QED.The scheme does not require the transfer of quantum information between the atoms and cavity.In the scheme the cavity is only virtually excited,so the requirement on the quality of the cavity is greatly loosened.

Related papers

Scheme for implementing quantum secret sharing via cavity QED

Zhihua Chen, Xiu‐Min Lin

An experimentally feasible scheme for implementing quantum secret sharing via cavity quantum electrodynamics (QED) is proposed. The scheme requires the large detuning of the cavity field from the atomic transition, the cavity is only virtually excited, thus the requirement on the quality factor of the cavity is greatly loosened.

Chinese Physics•Aug 25, 2005•10 citations

Scheme for implementing the Deutsch-Jozsa algorithm in cavity QED

Shi-Biao Zheng

We propose a scheme for realizing the Deutsch-Jozsa algorithm in cavity QED. The scheme is based on the resonant interaction of atoms with a cavity mode. The required experimental techniques are within the scope of what can be obtained in the microwave cavity QED setup. The experimental implementation of the scheme would be an important step toward more complex quantum computation in cavity QED.

Physical Review A•Sep 16, 2004•33 citations

The realization of entanglement, swap gate and quantum-information transfer for two-atom with cavity QED

Rong Wang, Jin-Yue Gao

We present a scheme to realize entangled states, swap gate and quantum-information transfer for two atoms in cavity QED. The scheme does not require the transfer of quantum information between the atoms and cavity and that the cavity field is only virtually excited, thus the requirement on the quality factor of the cavity is greatly loosened.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 11, 2005•0 citations

Implementation of Deutsch-Jozsa Algorithm Via Cavity QED

Mei Jin-feng

A scheme for the implementation of the two-qubit Deutsch-Jozsa algorithm using cavity QED was proposed.The advantages of the proposal are demonstrated as follows.One is that the cavity feld is only virtually excited and the photon-number-dependent part in the effective Hamiltonian is cancelled so that the system is insensitive to the cavity decay and the thermal field.The other one is that we don't require any Hadamard operation,which makes the schematic setup simple.Therefore,the present scheme is available based on the current technologies.

Journal of Fujian Normal University•Jan 1, 2008•0 citations

Efficient Scheme for Two-Atom Entanglement and Quantum Information Processing in Cavity QED

Shi‐Biao Zheng, Guang‐Can Guo

A scheme is proposed for the generation of two-atom maximally entangled states and realization of quantum logic gates and teleportation with cavity QED. The scheme does not require the transfer of quantum information between the atoms and cavity. In the scheme the cavity is only virtually excited and thus the requirement on the quality factor of the cavities is greatly loosened.

Physical Review Letters•Sep 11, 2000•1,200 citations

Implementing Deutsch–Jozsa Algorithm in Cavity QED

Dong Ping, Song Wei, Zhuo‐Liang Cao

We propose a simple scheme for implementing Deutsch–Jozsa algorithm in cavity QED. Our scheme is insensitive to both the cavity decay and thermal field because we use the large-detuned interaction. The scheme would be important to constructing practical computer in cavity QED system.

Communications in Theoretical Physics•Aug 1, 2006•3 citations
A scheme for the implementation of the two-qubit Deutsch-Jozsa algorithm using cavity QED was proposed.The advantages of the proposal are demonstrated as follows.One is that the cavity feld is only virtually excited and the photon-number-dependent part in the effective Hamiltonian is cancelled so that the system is insensitive to the cavity decay and the thermal field.The other one is that we don't require any Hadamard operation,which makes the schematic setup simple.Therefore,the present scheme is available based on the current technologies.