Advanced Mathematical and Computational Tools in Metrology (AMCTM)

A STATISTICAL MODEL FOR THE ANALYSIS OF SINGLE-PHOTON COUNTS

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

Published Mar 1, 2001• 0 citations
Publisher

Abstract

In this paper we report a theoretical approach for the evaluation of the distortion effects on photon statistics, measured by non-ideal devices with dead time. In particular we present a general method for the reconstruction of the distribution function of photon arrival times, by evaluating the probability to detect the n-th photon at a fixed time, in the presence of either extending or non-extending dead time.

DOI
10.1142/9789812811684_0005

Related papers

Theoretical aspects of photon number measurement

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

In this paper we report a theoretical analysis of the distortion effects on the probability distribution of the photon number for a classical state of light, induced by non-ideal detectors with non-unitary quantum efficiency and dead time. We present a theory for the reconstruction of the true photon arrival-time distribution, evaluating the probability of detecting the n -th photon at a fixed time.

Metrologia•Oct 1, 2000•20 citations

Distortion of photon-correlation functions in detection systems with paralyzable dead-time effects

Vladimir V. Apanasovich, Sergey Paltsev

We introduce an analytical model of the influence of paralyzable dead time on registered photon-correlation functions. Distortions of correlation functions in the case of the Poisson point process, the doubly stochastic Poisson point process, and the pairwise point process are calculated. The model permits the analysis of detection systems with constant and random dead times. The results of the analytical model are tested by computer simulation.

Journal of the Optical Society of America B•Sep 1, 1995•7 citations

Dead-time corrections to the statistical distribution of photoelectrons

Gabriel Bédard

The corrections to the photocount distributions, due to dead-time effects, are evaluated by use of the time-interval probability density of the counts. The normalized cumulative distribution function J k ( T , τ), associated with the detection of fluctuating light beams during a counting time interval T , with a counter having a constant dead-time τ, appear naturally as a convenient quantity to be used in comparing experimental results with theoretical predictions. The quantities J k ( T , τ) obey a simple recurrence relation and are readily derived from the photocount distribution p ( k, T , τ). A general expression is derived for J k ( T , τ) and p ( k, T , τ) associated with the detection of fluctuating light beams. Typical cumulative distribution functions, relating to the detection of thermal light, are evaluated as functions of the degree of polarization of the light, of the average number of photocounts < n 0 > in the absence of dead-time effects and of the ratio τ/ T . The distributions J k ( T , τ) and p ( k, T , τ) relating to detection of laser light are also calculated in a typical case.

Proceedings of the Physical Society•Jan 1, 1967•75 citations

Statistical Noise in Measuring Correlated Photon Beams

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel

Kluwer Academic Publishers eBooks•Feb 24, 2006•0 citations

Dead-time effects in photon counting statistics

S. K. Srinivasan

The paper deals with the modifications in photocount distributions due to dead-time following every registered count. In order to study the effects due to dead-time, the distribution of the interval between successive photocounts is studied. For the case of a constant dead-time, the mean count rate is derived using the dead-time neglected two-fold counting generating function. The result is also generalised to cover the case when the dead-time has a distribution with the different dead-times independently and identically distributed. In view of the complexity of the problem, a lower bound is obtained for the mean square number of photocounts in an arbitrary interval.

Journal of Physics A Mathematical and General•Nov 1, 1978•4 citations

Correlation avoidance in single-photon detecting quantum random number generators by dead time overestimation

Balázs Solymos, Ágoston Schranz, Miklós Telek

In the case of quantum random number generators based on single-photon arrivals, the physical properties of single-photon detectors, such as time-tagger clocks and dead time, influence the stochastic properties of the generated random numbers. This can lead to unwanted correlations among consecutive samples. We present a method based on extending the insensitive periods after photon detections. This method eliminates the unwanted stochastic effects at the cost of reduced generation speed. We calculate performance measures for our presented method and verify its correctness with computer simulations and measurements conducted on an experimental setup. Our algorithm has low complexity, making it convenient to implement in QRNG schemes, where the benefits of having uncorrelated output intervals exceed the disadvantages of the decreased rate.

EPJ Quantum Technology•Sep 19, 2024•6 citations
In this paper we report a theoretical approach for the evaluation of the distortion effects on photon statistics, measured by non-ideal devices with dead time. In particular we present a general method for the reconstruction of the distribution function of photon arrival times, by evaluating the probability to detect the n-th photon at a fixed time, in the presence of either extending or non-extending dead time.
The corrections to the photocount distributions, due to dead-time effects, are evaluated by use of the time-interval probability density of the counts. The normalized cumulative distribution function J k ( T , τ), associated with the detection of fluctuating light beams during a counting time interval T , with a counter having a constant dead-time τ, appear naturally as a convenient quantity to be used in comparing experimental results with theoretical predictions. The quantities J k ( T , τ) obey a simple recurrence relation and are readily derived from the photocount distribution p ( k, T , τ). A general expression is derived for J k ( T , τ) and p ( k, T , τ) associated with the detection of fluctuating light beams. Typical cumulative distribution functions, relating to the detection of thermal light, are evaluated as functions of the degree of polarization of the light, of the average number of photocounts < n 0 > in the absence of dead-time effects and of the ratio τ/ T . The distributions J k ( T , τ) and p ( k, T , τ) relating to detection of laser light are also calculated in a typical case.
Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel
The paper deals with the modifications in photocount distributions due to dead-time following every registered count. In order to study the effects due to dead-time, the distribution of the interval between successive photocounts is studied. For the case of a constant dead-time, the mean count rate is derived using the dead-time neglected two-fold counting generating function. The result is also generalised to cover the case when the dead-time has a distribution with the different dead-times independently and identically distributed. In view of the complexity of the problem, a lower bound is obtained for the mean square number of photocounts in an arbitrary interval.
In the case of quantum random number generators based on single-photon arrivals, the physical properties of single-photon detectors, such as time-tagger clocks and dead time, influence the stochastic properties of the generated random numbers. This can lead to unwanted correlations among consecutive samples. We present a method based on extending the insensitive periods after photon detections. This method eliminates the unwanted stochastic effects at the cost of reduced generation speed. We calculate performance measures for our presented method and verify its correctness with computer simulations and measurements conducted on an experimental setup. Our algorithm has low complexity, making it convenient to implement in QRNG schemes, where the benefits of having uncorrelated output intervals exceed the disadvantages of the decreased rate.