Frontiers in Optics

Laser Based, Single Trapped Ion Optical Atomic Clock with 1 × 10−17 Uncertainty Evaluated using the Time-Dilation Effect

Alan A. Madej, P. Dubé, Maria Tibbo, J. E. Bernard

Published Jan 1, 2014• 0 citations
Publisher

Abstract

An atomic frequency reference using a single trapped ion has been evaluated to 1.2×10−17 uncertainty by exploiting the experimentally observed cancellation of micromotion induced Stark and time dilation shifts on the 88Sr+ 445-THz S-D transition.
DOI
10.1364/fio.2014.fw5c.2

Related papers

Experimental confirmation of micromotion shift cancellation via operation at trap magic frequency and reduction in evaluated systematic uncertainties for the 88Sr+ optical frequency standard at 445 THz

Alan A. Madej, P. Dubé, Maria Tibbo +1 more

We describe recent experiments and results which show the effective cancellation of micromotion induced systematic shifts for the 445-THz reference transition in a trapped and laser cooled88Sr+single ion reference. Using two different ion trap systems based on a Paul and endcap design, the critical or magic frequency at which micromotion effects cancel has been effectively measured at 14.4 MHz. This work also allows an improved determination of the polarizability difference of the ground and excited states and an improvement in the evaluated blackbody shifts to the low 10-17level.

Conference on Precision Electromagnetic Measurements•Aug 1, 2014•0 citations

88Sr+ Single-Ion Optical Frequency Standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The electric quadrupole shift is an important source of systematic uncertainty in several single-ion optical frequency standards. In this paper, we review the electric quadrupole shift cancellation method based on the Zeeman spectrum of the clock transition. The method is demonstrated with an actual frequency measurement of the 5s2S1/2-4d2D5/2transition of88Sr+. This cancellation method also removes shifts from the tensor part of the Stark effect. Further analysis of the data provides an evaluation of the micromotion shifts which are then applied to correct the observed ion clock frequency. Recent improvements to our probe laser system and the observation of Fourier-transform limited linewidths of 5 Hz at 445 THz are also reported

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•8 citations

Subkilohertz comparison of the single-ion optical-clock 2S1/2−2D5/2 transition in two 88Sr+ traps

G. P. Barwood, Guozheng Huang, Hugh A. Klein +2 more

A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single ${}^{88}{\mathrm{Sr}}^{+}$ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in ${10}^{11}$ per hour. The difference between center frequencies of the single ${}^{88}{\mathrm{Sr}}^{+}$-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in ${10}^{13}.$

Physical Review A•May 1, 1999•27 citations

A dual species optical atomic clock

Martin Steinel

Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)

•Dec 16, 2025•0 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

Optimization of a RF Single Ion Paul Trap for a 88Sr+ Ion Optical Clock Comparison

Maria Tibbo

As part of the ongoing world-wide effort in improving time and frequency references, a high accuracy optical frequency standard was developed using the electric quadrupole allowed clock transition at 445 THz (674 nm) in a trapped and laser cooled 88Sr+ion. An ion trap system of the endcap design has been recently evaluated with a fractional frequency uncertainty which surpasses the accuracy of the current realization of the SI second. This thesis seeks to further evaluate the limiting systematic shifts of the device by optimizing a second ion trap reference based on a rf Paul trap design, which was then compared with the endcap trap reference frequency. The comparison of the two ion traps' reference frequencies confirmed an overall offset of -0.36 pm 0.08 Hz at the 445 THz reference frequency corresponding to a fractional frequency offset of 8 x 10^-16.

•Jan 1, 2013•0 citations
We describe recent experiments and results which show the effective cancellation of micromotion induced systematic shifts for the 445-THz reference transition in a trapped and laser cooled88Sr+single ion reference. Using two different ion trap systems based on a Paul and endcap design, the critical or magic frequency at which micromotion effects cancel has been effectively measured at 14.4 MHz. This work also allows an improved determination of the polarizability difference of the ground and excited states and an improvement in the evaluated blackbody shifts to the low 10-17level.
The electric quadrupole shift is an important source of systematic uncertainty in several single-ion optical frequency standards. In this paper, we review the electric quadrupole shift cancellation method based on the Zeeman spectrum of the clock transition. The method is demonstrated with an actual frequency measurement of the 5s2S1/2-4d2D5/2transition of88Sr+. This cancellation method also removes shifts from the tensor part of the Stark effect. Further analysis of the data provides an evaluation of the micromotion shifts which are then applied to correct the observed ion clock frequency. Recent improvements to our probe laser system and the observation of Fourier-transform limited linewidths of 5 Hz at 445 THz are also reported
A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in 1011{10}^{11}1011 per hour. The difference between center frequencies of the single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in 1013.{10}^{13}.1013.
Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
As part of the ongoing world-wide effort in improving time and frequency references, a high accuracy optical frequency standard was developed using the electric quadrupole allowed clock transition at 445 THz (674 nm) in a trapped and laser cooled 88Sr+ion. An ion trap system of the endcap design has been recently evaluated with a fractional frequency uncertainty which surpasses the accuracy of the current realization of the SI second. This thesis seeks to further evaluate the limiting systematic shifts of the device by optimizing a second ion trap reference based on a rf Paul trap design, which was then compared with the endcap trap reference frequency. The comparison of the two ion traps' reference frequencies confirmed an overall offset of -0.36 pm 0.08 Hz at the 445 THz reference frequency corresponding to a fractional frequency offset of 8 x 10^-16.