Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Pulse Recycling and Weak Value Metrology

Courtney L. Byard, Trent Graham, Andrew N. Jordan, Paul G. Kwiat

Published Jan 1, 2015• 1 citation
Publisher

Abstract

Recycling undetected photons in a weak measurement can substantially improve the signal-to-noise ratio. We demonstrate a preliminary improvement by a factor of 1.36 over a system with no recycling, potentially reaching a factor of 4.
DOI
10.1364/fio.2015.jw2a.69

Related papers

Weak Value Measurements with Pulse Recycling

Courtney Krafczyk, Trent Graham, Andrew N. Jordan +1 more

Recycling undetected photons in a weak measurement can substantially improve the signal-to-noise ratio. We demonstrate a preliminary improvement by a factor of 1.36 over a system with no recycling, potentially reaching a factor of 3.2.

Frontiers in Optics•Jan 1, 2016•0 citations

Increasing Weak Measurement SNR with Recycling

Courtney L. Byard, Trent Graham, Andrew N. Jordan +1 more

Recycling unmeasured photons in a system utilizing weak measurements can substantially improve the signal-to-noise ratio, even in a double-pass system. We achieve an improvement by a factor of 1.36 over a system without recycling.

Conference on Lasers and Electro-Optics•Jan 1, 2014•0 citations

Increasing the Signal-to-Noise Ratio in Weak-Value Measurements

Courtney L. Byard, Trent Graham, Ariel Danan +2 more

By recycling non-post selected photons through a Sagnac interferometer in our optical weak measurement of a mirror tilt, we double the detected intensity, resulting in a signal-to-noise ratio improvement of 1.57 over un-recycled experiments.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•0 citations

Enhanced Weak-Value Amplification via Photon Recycling

Courtney Krafczyk, Andrew N. Jordan, M. E. Goggin +1 more

In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.

arXiv:2104.14393•Physical Review Letters•Jun 1, 2021•43 citations

Using Recycling to Increase the Signal-to-Noise Ratio in Weak Measurements

Courtney L. Byard, Trent Graham, Andrew N. Jordan +1 more

Get PDF Email Share Share with Facebook Tweet This Post on reddit Share with LinkedIn Add to CiteULike Add to Mendeley Add to BibSonomy Get Citation Copy Citation Text C. Byard, T. Graham, A. Jordan, and P. Kwiat, "Using Recycling to Increase the Signal-to-Noise Ratio in Weak Measurements," in Research in Optical Sciences , OSA Technical Digest (online) (Optica Publishing Group, 2014), paper QTh4A.3. Export Citation BibTex Endnote (RIS) HTML Plain Text Citation alert Save article

Research in Optical Sciences•Jan 1, 2014•0 citations

Signal-to-Noise Ratio Enhancement in Weak Measurement, and its Application to Observing Single-Photon-Level Nonlinearities

Amir Feizpour, Xingxgin Xing, Aephraim M. Steinberg

We show theoretically that weak-value amplification can enhance the signal-to-noise ratio in the presence of noise with long correlation times, in particular for measurements of single-photon-level nonlinearities.

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations
In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.