Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser & Optoelectronics Progress

Absolute Rotation Measurement for Space-Domain Raman Pulses Cold Atom Gyroscope

邹鹏飞 Zou Pengfei, 颜树华 Yan Shuhua, 林存宝 Lin Cunbao

Published Jan 1, 2014• 1 citation
Publisher
DOI
10.3788/lop51.051201

Related papers

Accurate rotation measurement with a cold atom gyroscope

Romain Gautier, Leonid A. Sidorenkov, Matteo Altorio +2 more

•Jul 19, 2020•0 citations

Rotation Measurements with a Large-area Dual-axis Cold Atom Gyroscope

Arnaud Landragin, Romain Gautier, Mohamed Guessoum +3 more

•Jul 19, 2021•0 citations

Continuous cold atom gyroscope with 1 nrad.s-1 rotation stability

Denis Savoie, Matteo Altorio, Bess Fang +5 more

•Jul 3, 2017•0 citations

Realization of a cold atom gyroscope in space

Jinting Li, Xi Chen, Danfang Zhang +21 more

High-precision gyroscopes in space are essential for fundamental physics research and navigation. Due to its potential high precision, the cold atom gyroscope is expected to be one of the next generation of gyroscopes in space. Here, we report the first realization of a cold atom gyroscope, which was demonstrated by the atom interferometer installed in the China Space Station (CSS) as a payload. By compensating for the CSS's high dynamic rotation rate using a built-in piezoelectric mirror, spatial interference fringes in the interferometer are successfully obtained. Then, the optimized ratio of the Raman laser's angles is derived, the coefficients of the piezoelectric mirror are self-calibrated in orbit, and various systemic effects are corrected. We achieve a rotation measurement resolution of 50 μrad/s for a single shot and 17 μrad/s for an average number of 32. The measured rotation is -1142 ± 29 μrad/s and is compatible with that recorded by the classical gyroscope of the CSS. This study paves the way for developing high-precision cold atom gyroscopes in space.

arXiv:2405.20659•National Science Review•Jan 11, 2025•21 citations

The Implementation of a Compact Cold Atom Interference Gyroscope Based on Miniaturized Quartz Vacuum Chamber

Yingpeng Zhao, Dianrong Li, Jingyu Niu +11 more

The cold atom interference gyroscope (CAIG) offer substantial potential for rotation measurement due to the high sensitivity and stability. The CAIG with a fountain configuration realized by four-pulse could provide a larger interference-loop area, and enhanced performance. However, this kind of CAIG is usually much larger and higher since it requires a vacuum chamber with sufficient height to achieve a long Raman pulse interval. We demonstrate a four-pulse CAIG based on a miniaturized vacuum chamber that enables portable and transportable rotation rate measurements. The main vacuum chamber is realized by whole glass material. The height of the vacuum unit is 0.7 m, the volume is${{8}.{86} \times {10}^{{4}}}~{{\textrm {cm}}^{{3}}}$, and the mass is 75 kg. Then, we estimated the performance of our portable CAIG in the environment of the underground laboratory and the fifth-floor office building. In the laboratory, the sensitivities of the homemade CAIG is${4}.{44}\times {10}^{-{6}}$rad/s$/(\text {Hz})^{1/2}$with an interrogation time of 55 ms and an interference area of 25 mm2. In addition, we measured the angular velocity of the Earth, the relative error is 2.4%. Furthermore, we transported the CAIG to the fifth floor of the office building, which is near the subway. Ultimately, the CAIG achieved a sensitivity of${5}.{47}\times {10}^{-{4}}$rad/s$/(\text {Hz})^{1/2}$. Additionally, the theoretical maximum interrogation time achieved by this CAIG is 124 ms corresponding to a sensitivity of${{5}.{62}\times {10}^{-{8}}}~{/(\text {Hz})^{1/2}}$. Our new design of the compact CAIG could provide novel insights into the miniaturization of CAIGs, while also pointing out areas for further improvement.

IEEE Sensors Journal•Oct 25, 2024•5 citations

A new generation of inertial measurement instrument: Raman-type atom interferometric gyroscope

Kai Wang, Yao Zhanwei, Si-Bin Lu +3 more

•Jan 1, 2016•0 citations
High-precision gyroscopes in space are essential for fundamental physics research and navigation. Due to its potential high precision, the cold atom gyroscope is expected to be one of the next generation of gyroscopes in space. Here, we report the first realization of a cold atom gyroscope, which was demonstrated by the atom interferometer installed in the China Space Station (CSS) as a payload. By compensating for the CSS's high dynamic rotation rate using a built-in piezoelectric mirror, spatial interference fringes in the interferometer are successfully obtained. Then, the optimized ratio of the Raman laser's angles is derived, the coefficients of the piezoelectric mirror are self-calibrated in orbit, and various systemic effects are corrected. We achieve a rotation measurement resolution of 50 μrad/s for a single shot and 17 μrad/s for an average number of 32. The measured rotation is -1142 ± 29 μrad/s and is compatible with that recorded by the classical gyroscope of the CSS. This study paves the way for developing high-precision cold atom gyroscopes in space.
The cold atom interference gyroscope (CAIG) offer substantial potential for rotation measurement due to the high sensitivity and stability. The CAIG with a fountain configuration realized by four-pulse could provide a larger interference-loop area, and enhanced performance. However, this kind of CAIG is usually much larger and higher since it requires a vacuum chamber with sufficient height to achieve a long Raman pulse interval. We demonstrate a four-pulse CAIG based on a miniaturized vacuum chamber that enables portable and transportable rotation rate measurements. The main vacuum chamber is realized by whole glass material. The height of the vacuum unit is 0.7 m, the volume is8.86×104 cm3{{8}.{86} \times {10}^{{4}}}~{{\textrm {cm}}^{{3}}}8.86×104 cm3, and the mass is 75 kg. Then, we estimated the performance of our portable CAIG in the environment of the underground laboratory and the fifth-floor office building. In the laboratory, the sensitivities of the homemade CAIG is4.44×10−6{4}.{44}\times {10}^{-{6}}4.44×10−6rad/s/(Hz)1/2/(\text {Hz})^{1/2}/(Hz)1/2with an interrogation time of 55 ms and an interference area of 25 mm2. In addition, we measured the angular velocity of the Earth, the relative error is 2.4%. Furthermore, we transported the CAIG to the fifth floor of the office building, which is near the subway. Ultimately, the CAIG achieved a sensitivity of5.47×10−4{5}.{47}\times {10}^{-{4}}5.47×10−4rad/s/(Hz)1/2/(\text {Hz})^{1/2}/(Hz)1/2. Additionally, the theoretical maximum interrogation time achieved by this CAIG is 124 ms corresponding to a sensitivity of5.62×10−8 /(Hz)1/2{{5}.{62}\times {10}^{-{8}}}~{/(\text {Hz})^{1/2}}5.62×10−8 /(Hz)1/2. Our new design of the compact CAIG could provide novel insights into the miniaturization of CAIGs, while also pointing out areas for further improvement.