The effect of the pump bandwidth on the quantum statistical properties of Raman lasers is investigated. It is shown that the pump bandwidth may lead to the enhancement of output intensity noise squeezing even though it reduces the Mandel parameter.
We investigate the influence of pump bandwidth and pump intensity noise on the quantum-noise properties of lasers based on a Raman atomic-gain medium, which recently have been predicted to emit narrow-bandwidth, sub-shot-noise light. We show that, using finite-bandwidth pump light, the predicted limit to the laser bandwidth can still be well below the value given by the Shawlow-Townes formula and much smaller than the input bandwidth. The laser intensity noise is shown to be relatively insensitive to input phase noise as long as the Rabi frequency on the lasing transition is large compared to the bandwidth. On the other hand, even small amounts of pump amplitude noise tend to increase strongly the laser spectral bandwidth, especially in the high-intensity limit. Including dynamic pump-noise reduction through multilevel atomic cycling in our model leads to a Mandel Q parameter value even below Q=-1/2, together with a significant enhancement of the output intensity-noise squeezing.
We investigate the effect of collisional broadening, of population trapping and repumping, and of detuning of the atomic levels on the quantum-statistical properties of Raman laser radiation. We find that under suitably chosen operating conditions the effect of such additional incoherent relaxation mechanisms for the atomic polarization and populations can be made very small. One obtains highly nonclassical values for the Mandel Q parameter and the output-intensity fluctuation spectrum S(\ensuremath{\omega}) for experimentally reasonable parameters. Including detuning of the laser and the pump light from the atomic levels in certain cases can lead to further narrowing of the intracavity photon number distribution, as compared to the resonant case, down to a Mandel Q parameter close to the optimum possible value of Q=-1. A subsequent preliminary analysis prevails that inhomogeneous Doppler broadening of the atomic lines, both for collinear and for counterpropagating pump and laser light, is not detrimental to the nonclassical intracavity state.
We demonstrate that the intensity fluctuations of a laser with a Raman gain medium, described by a large number of independent 3-level atoms, can drop well below the shot noise level. In the limit of a good cavity, where one can adiabatically eliminate the atoms, we find an optimum Mandel Q parameter of Q ≈ −1/2 over a large range of parameters, when the laser is operated well above threshold. This leads to a strong suppression of the low-frequency quantum fluctuations in the laser output. In addition we find that due to suppression of spontaneous emission into the lasing mode, the spectral linewidth of the emitted light can be reduced below the Schawlow-Townes limit by more than one order of magnitude.
We study in detail the influence of pumping statistics on the laser dynamics. We apply the technique of quantum Langevin operators and generalize the corresponding noise operators to incorporate the statistical properties of the pump mechanism. These equations are then used to derive expressions for the phase and intensity fluctuations of lasers with various pump statistics. We find that a reduction of pump noise can lead to a significant squeezing of the photon number noise below the shot-noise limit. This is in complete agreement with our previous analysis, which used a density-operator approach.
The quantum noise properties of injection-locked semiconductor laser oscillators are investigated. Included in the analysis are pump-noise suppression and squeezing of the injection signal. It is shown that the main effect of injection locking is the reduction of the phase noise of the outgoing laser light field. The influence that squeezing of the injection signal state has on the output state is shown to be strongly dependent on the value of the linewidth enhancement factor. In general, little or no noise reduction stands to be gained by squeezing the injection signal. It is also shown that under idealized conditions, the spectral uncertainty product of the outgoing field will approach, but never go below, the minimum uncertainty value given by the Heisenberg uncertainty relation.