Advances in Optical Sciences Congress

Imaging Resolution Improvement Using Transverse Phase Amplification

D. French, Zhifeng Huang, Hsien‐Ping Pao, Igor Jovanovic

Published Jan 1, 2009• 0 citations
Publisher

Abstract

Transverse phase amplification of spatially multimode beams can be achieved via phase-sensitive optical parametric amplification. Transverse phase amplification of the signal in the canonical imaging problem can improve imaging resolution beyond the Rayleigh limit.
DOI
10.1364/nlo.2009.nfb4

Related papers

Assessment of image resolution improvement by phase-sensitive optical parametric amplification

Zhifeng Huang, D. French, Hsueh‐Yuan Pao +1 more

Classical information theory can be used to quantify the resolution performance of optical imaging systems. When an optical parametric amplifier (OPA) operated as a phase-sensitive amplifier (PSA) in the transverse spatial domain is used for point source imaging, the angular resolution improvement can approach the de Broglie resolution (i.e. Heisenberg limit). In this paper, classical information theory is employed to quantify the signal-to-noise ratio (SNR) improvement for both an ideal and a realistic multimode PSA applied to the problem of sub-Rayleigh imaging. When only considering the noise originating from the detector, the SNR improvement is found to scale quadratically as a function of the PSA gain, in the limit of noise power comparable to signal power. Differences in performance of an ideal PSA and a realistic PSA are discussed.

Applied Physics B•Jun 17, 2010•3 citations

Improvement of Image Resolution beyond Classical Limit by Phase-sensitive Optical Parametric Amplifier

Zun Huang, Douglas French, Igor Jovanovic +1 more

When an optical parametric amplifier (OPA) operated as a phase-sensitive amplifier (PSA) is used for point source imaging, the angular resolution improvement can defeat the classical Rayleigh limit, and approach the de Broglie resolution.

•Jan 1, 2011•0 citations

Phase-Sensitive Three-Wave Mixing for Imaging Resolution Improvement

D. French, Zhifeng Huang, Igor Jovanovic

Phase-sensitive three-wave mixing operated in the deamplification mode can produce angular phase amplification for multimode beams. A detailed analysis of this scheme indicates that super-Rayleigh imaging resolution is expected.

Conference on Lasers and Electro-Optics•Jan 1, 2009•0 citations

Improvement Of Image Resolution Beyond Classical Limit By Phase-Sensitive Optical Parametric Amplifier

Zhifeng Huang, D. French, H-Y. Pao +1 more

When an optical parametric amplifier (OPA) operated as a phase-sensitive amplifier (PSA) is used for point source imaging, the angular resolution improvement can defeat the classical Rayleigh limit, and approach the de Broglie resolution.

Imaging and Applied Optics•Jan 1, 2011•0 citations

Continuous-wave phase-sensitive parametric image amplification

Sylvain Gigan, L. Lopez, V. Delaubert +3 more

We study experimentally parametric amplification in the continuous regime using a transverse-degenerate type-II Optical Parametric Oscillator operated below threshold. We demonstrate that this device is able to amplify either in the phase insensitive or phase sensitive way first a single mode beam, then a multimode image. Furthermore the total intensities of the amplified image projected on the signal and idler polarizations are shown to be correlated at the quantum level.

arXiv:quant-ph/0502116•Journal of Modern Optics•Feb 21, 2006•20 citations

Phase-sensitive amplification for imaging resolution improvement and plasma interferometry

Zun Huang

The Rayleigh criterion sets a classical limit on the resolution of optical imaging systems, which brings challenges in remote sensing of spatial information. According to the Rayleigh criterion, only a limited control of resolution can be accomplished by adjusting the optical wavelength or aperture diameter. The resolvability of optical imaging systems can also be represented in terms of the signal-to-noise ratio (SNR). The optical parametric amplier (OPA) is a common nonlinear device used in a variety of applications, such as imaging, quantum information, and ultrafast laser science. It has been shown that when the OPA is operated as a phase-sensitive amplifier (PSA), no quantum noise is added thus preserving the SNR. In this thesis, the hypothesis testing from the classical information theory has been applied to the problem of distinguishing distant point sources. It is numerically demonstrated that an improvement of resolution beyond the classical limit and SNR enhancement could be achieved by utilizing the PSA operated in spatial domain. Plasma diagnostics deducts information of important parameters (such as temperature, plasma density and confinement) in magnetic confinement fusion (MCF) reactions. Interferometer can be used to measure the refractive index of plasma which is correlated with the plasma density. A Mach-Zehnder type interferometer enhanced by the PSA is studied. It has been found that the effect of the PSA is to increase the minimum resolvable interference fringe shift caused by plasma density perturbation so that a better resolution of the interferogram can be obtained. This method may enable significant improvement in plasma density measurement.

•Jan 1, 2009•0 citations
Classical information theory can be used to quantify the resolution performance of optical imaging systems. When an optical parametric amplifier (OPA) operated as a phase-sensitive amplifier (PSA) in the transverse spatial domain is used for point source imaging, the angular resolution improvement can approach the de Broglie resolution (i.e. Heisenberg limit). In this paper, classical information theory is employed to quantify the signal-to-noise ratio (SNR) improvement for both an ideal and a realistic multimode PSA applied to the problem of sub-Rayleigh imaging. When only considering the noise originating from the detector, the SNR improvement is found to scale quadratically as a function of the PSA gain, in the limit of noise power comparable to signal power. Differences in performance of an ideal PSA and a realistic PSA are discussed.
The Rayleigh criterion sets a classical limit on the resolution of optical imaging systems, which brings challenges in remote sensing of spatial information. According to the Rayleigh criterion, only a limited control of resolution can be accomplished by adjusting the optical wavelength or aperture diameter. The resolvability of optical imaging systems can also be represented in terms of the signal-to-noise ratio (SNR). The optical parametric amplier (OPA) is a common nonlinear device used in a variety of applications, such as imaging, quantum information, and ultrafast laser science. It has been shown that when the OPA is operated as a phase-sensitive amplifier (PSA), no quantum noise is added thus preserving the SNR. In this thesis, the hypothesis testing from the classical information theory has been applied to the problem of distinguishing distant point sources. It is numerically demonstrated that an improvement of resolution beyond the classical limit and SNR enhancement could be achieved by utilizing the PSA operated in spatial domain. Plasma diagnostics deducts information of important parameters (such as temperature, plasma density and confinement) in magnetic confinement fusion (MCF) reactions. Interferometer can be used to measure the refractive index of plasma which is correlated with the plasma density. A Mach-Zehnder type interferometer enhanced by the PSA is studied. It has been found that the effect of the PSA is to increase the minimum resolvable interference fringe shift caused by plasma density perturbation so that a better resolution of the interferogram can be obtained. This method may enable significant improvement in plasma density measurement.