Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Cold ion–polar-molecule reactions studied with a combined Stark-velocity-filter–ion-trap apparatus

K. Okada, T Suganuma, Takahiro Furukawa, Toshinobu Takayanagi, M. Wada, Hans A. Schuessler

Published Apr 26, 2013• 25 citations
Publisher

Abstract

We have developed a combined Stark-velocity-filter--ion-trap apparatus for the purpose of reaction-rate measurements between cold trapped ions and slow polar molecules under ultrahigh vacuum conditions. The prerequisite steps such as the characterization of velocity-selected polar molecules (PM), namely ND${}_{3}$, H${}_{2}$CO, and CH${}_{3}$CN, were performed using time-of-flight (TOF) measurements. We confirmed the generation of slow ND${}_{3}$, H${}_{2}$CO, and CH${}_{3}$CN molecules having thermal energies of a few Kelvin. Additionally, the number densities of the slow velocity-filtered polar molecules were determined to be in the range of $n={10}^{4}$ to 10${}^{6}$ cm${}^{\ensuremath{-}3}$ by calibrating the TOF signals. In a first experiment, the Stark velocity filter was connected to a cryogenic linear Paul trap and reaction-rate measurements between laser-cooled Ca${}^{+}$ Coulomb crystals and velocity-selected polar molecules were carried out. The observed reaction rates are of the order of 10${}^{\ensuremath{-}5}$ s${}^{\ensuremath{-}1}$, which are much slower than typical reaction rates of molecular ion--polar-molecule reactions at low temperatures. The present results confirm that reaction-rate measurements between velocity-selected polar molecules and sympathetically cooled molecular ions cooled by a laser-cooled Ca${}^{+}$ Coulomb crystal can be performed. Next we measured the reaction rates between sympathetically cooled nonfluorescent stored ion molecules namely N${}_{2}$H${}^{+}$ ions and velocity-selected CH${}_{3}$CN molecules at the average reaction energy of about 3 K. The measured reaction rate of 2.0(2)$\ifmmode\times\else\texttimes\fi{}$10${}^{\ensuremath{-}3}$ s${}^{\ensuremath{-}1}$ is much faster than those of the Ca${}^{+}$+PM reactions. This is strong evidence that the velocity-selected polar molecules undergo reactive collisions. We also confirmed that the present reaction-rate constant of CH${}_{3}$CN+N${}_{2}$H${}^{+}$ $\ensuremath{\rightarrow}$ CH${}_{3}$CNH${}^{+}$+N${}_{2}$ is consistent with the estimated values from the room temperature results and the trajectory-scaling formula of Su et al. In the future, the present velocity-filter combined cryogenic trap apparatus will enable us to perform systematic measurements of cold ion--polar-molecule reactions, which are important problems from a fundamental viewpoint and also contribute to astrochemistry.

DOI
10.1103/physreva.87.043427

Related papers

Ion-molecule chemistry at very low temperatures: cold chemical reactions between Coulomb-crystallized ions and velocity-selected neutral molecules

Martin T. Bell, Alexander D. Gingell, James M. Oldham +2 more

The recent development of a range of techniques for producing cold atoms and molecules at very low translational temperatures T < or = 1 K has provided the opportunity to investigate collisional processes in a new physical regime. We have recently presented a new experimental method to study low-temperature reactive collisions between translationally cold ions and neutral molecules (S. Willitsch et al., Phys. Rev. Lett. 2008, 100, 043203). Our technique relies on the combination of a quadrupole-guide velocity selector for the generation of translationally cold neutral molecules with a facility to produce ordered structures of cold ions (Coulomb crystals) by laser cooling in a linear quadrupole ion trap. The strong localisation of the ions in the trap in combination with the high sensitivity of laser-induced-fluorescence detection enabled us to study chemical reactions on the single-particle level, down to temperatures of T approximately 1 K. In the current paper, we present a detailed characterisation of the scope and limitations of this method based on our study of the reaction between laser-cooled Ca+ ions and velocity-selected CH3F molecules. The properties of our cold-neutrals source and the dependence of the measured rate constant on the shape of the Coulomb crystals, trapping and laser-cooling parameters are discussed. An extension of our technique for the study of low-temperature reactions with sympathetically cooled molecular ions (translational temperature T > 10 mK) is presented and first results on the charge-transfer reaction between OCS+ and ND3 are discussed. Finally, perspectives for further developments of our method are explored.

Faraday Discussions•Jan 1, 2009•74 citations

Digital ion trap mass spectrometry for cold ion-molecule chemistry

Laura L. Pollum

A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.

•Jan 1, 2015•0 citations

A Stark velocity filter for studying cold polar molecule–molecular ion reactions

T Suganuma, K. Okada, Naoki Kimura +3 more

A Stark velocity filter has been developed for studying molecular ion-polar molecule reactions at very low temperatures. We have successfully produced slow polar molecules of ND 3 , NH 3 and CH 2 O with a peak velocity of lower than 40 m/s. The property of the Stark velocity filter was systematically studied by changing the Stark voltage, the nozzle pressure and the source gas temperature. Finally the number density of the extracted slow molecules was determined.

Journal of Physics Conference Series•Nov 5, 2012•0 citations

Combination of a cold ion and cold molecular source

James M. Oldham

This thesis describes the combination of two sources of cold atomic or molecular species which can be used to study a wide range of ion-molecule reactions. The challenges in forming these species and in determining the fate of reactive events are explored throughout. Reactions occur in a volume within a radio-frequency ion trap, in which ions have previously been cooled to sub-Kelvin temperatures. Ions are laser-cooled, with migration of ions slowed sufficiently to form a quasi-crystalline spheroidal structure, deemed a Coulomb crystal. Fluorescence emitted as a consequence of laser-cooling is detected; the subsequent fluorescence profiles are used to determine the number of ions in the crystal and, in combination with complementary simulations, the temperature of these ions. Motion imparted by trapping fields can be substantial and simulations are required to accurately determine collision energies. A beam of decelerated molecules is aimed at this stationary ion target. An ammonia seeded molecular beam enters a Stark decelerator, based on the original design of Meijer and co-workers. The decelerator uses time-varying electric fields to remove kinetic energy from the molecules, which exit at speeds down to 35 m/s. A fast-opening shutter and focussing elements are subsequently used to maximise the decelerated flux in the reaction volume while minimising undecelerated molecule transmission. Substantial fluxes of decelerated ammonia are obtained with narrow velocity distributions to provide a suitable source of reactant molecules. Combination of these two techniques permits studies of reactions between atomic ions and decelerated molecules that can be entirely state-specific. Changes in the Coulomb crystal fluorescence profile denote changes in the ion identities, the rate of these changes can be used to obtain rate constants. Determination of rate constants is even possible despite the fact that neither reactant nor product ions are directly observed. This work has studied reactions between sympathetically cooled Xe+ ions and guided ND3 and has obtained data consistent with prior studies. Determination of reactive events is complicated if ion identities can change without affecting the fluorescence profile, or if multiple reaction channels are possible. A range of spectroscopic techniques are discussed and considered in regards to determining rate constants and product identities. Pulsed axial excitation of trapped ions can follow rapid changes in average ion weights and subtle changes for small crystals. Time-of-flight mass spectrometry is also demonstrated using the trapping electrodes and is suitable for discrimination of ions formed within the trap.

•Jan 1, 2014•1 citation

Cold Reactive Collisions between Laser-Cooled Ions and Velocity-Selected Neutral Molecules

Stefan Willitsch, Martin T. Bell, Alexander D. Gingell +2 more

We report a new experimental method to study reactive ion-molecule collisions at very low temperatures. A source of laser-cooled ions in a linear Paul trap has been combined with a quadrupole-guide velocity selector to investigate the reaction of Ca+ with CH3F at collision energies E[over](coll)/k(B)> or =1 K with single-particle sensitivity. The technique represents a general approach to study reactive collisions between ions and polar molecules over a wide temperature range down to the cold regime.

Physical Review Letters•Jan 30, 2008•234 citations

Cold reactive collisions between neutral molecules and trapped ions

Lorenzo Salvatore Petralia

This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.

•Jan 1, 2018•0 citations
We have developed a combined Stark-velocity-filter--ion-trap apparatus for the purpose of reaction-rate measurements between cold trapped ions and slow polar molecules under ultrahigh vacuum conditions. The prerequisite steps such as the characterization of velocity-selected polar molecules (PM), namely ND3{}_{3}3​, H2{}_{2}2​CO, and CH3{}_{3}3​CN, were performed using time-of-flight (TOF) measurements. We confirmed the generation of slow ND3{}_{3}3​, H2{}_{2}2​CO, and CH3{}_{3}3​CN molecules having thermal energies of a few Kelvin. Additionally, the number densities of the slow velocity-filtered polar molecules were determined to be in the range of n=104n={10}^{4}n=104 to 106{}^{6}6 cm\ensuremath−3{}^{\ensuremath{-}3}\ensuremath−3 by calibrating the TOF signals. In a first experiment, the Stark velocity filter was connected to a cryogenic linear Paul trap and reaction-rate measurements between laser-cooled Ca+{}^{+}+ Coulomb crystals and velocity-selected polar molecules were carried out. The observed reaction rates are of the order of 10\ensuremath−5{}^{\ensuremath{-}5}\ensuremath−5 s\ensuremath−1{}^{\ensuremath{-}1}\ensuremath−1, which are much slower than typical reaction rates of molecular ion--polar-molecule reactions at low temperatures. The present results confirm that reaction-rate measurements between velocity-selected polar molecules and sympathetically cooled molecular ions cooled by a laser-cooled Ca+{}^{+}+ Coulomb crystal can be performed. Next we measured the reaction rates between sympathetically cooled nonfluorescent stored ion molecules namely N2{}_{2}2​H+{}^{+}+ ions and velocity-selected CH3{}_{3}3​CN molecules at the average reaction energy of about 3 K. The measured reaction rate of 2.0(2)\ifmmode×\else\texttimes\fi\ifmmode\times\else\texttimes\fi{}\ifmmode×\else\texttimes\fi10\ensuremath−3{}^{\ensuremath{-}3}\ensuremath−3 s\ensuremath−1{}^{\ensuremath{-}1}\ensuremath−1 is much faster than those of the Ca+{}^{+}++PM reactions. This is strong evidence that the velocity-selected polar molecules undergo reactive collisions. We also confirmed that the present reaction-rate constant of CH3{}_{3}3​CN+N2{}_{2}2​H+{}^{+}+ \ensuremath→\ensuremath{\rightarrow}\ensuremath→ CH3{}_{3}3​CNH+{}^{+}++N2{}_{2}2​ is consistent with the estimated values from the room temperature results and the trajectory-scaling formula of Su et al. In the future, the present velocity-filter combined cryogenic trap apparatus will enable us to perform systematic measurements of cold ion--polar-molecule reactions, which are important problems from a fundamental viewpoint and also contribute to astrochemistry.
The recent development of a range of techniques for producing cold atoms and molecules at very low translational temperatures T < or = 1 K has provided the opportunity to investigate collisional processes in a new physical regime. We have recently presented a new experimental method to study low-temperature reactive collisions between translationally cold ions and neutral molecules (S. Willitsch et al., Phys. Rev. Lett. 2008, 100, 043203). Our technique relies on the combination of a quadrupole-guide velocity selector for the generation of translationally cold neutral molecules with a facility to produce ordered structures of cold ions (Coulomb crystals) by laser cooling in a linear quadrupole ion trap. The strong localisation of the ions in the trap in combination with the high sensitivity of laser-induced-fluorescence detection enabled us to study chemical reactions on the single-particle level, down to temperatures of T approximately 1 K. In the current paper, we present a detailed characterisation of the scope and limitations of this method based on our study of the reaction between laser-cooled Ca+ ions and velocity-selected CH3F molecules. The properties of our cold-neutrals source and the dependence of the measured rate constant on the shape of the Coulomb crystals, trapping and laser-cooling parameters are discussed. An extension of our technique for the study of low-temperature reactions with sympathetically cooled molecular ions (translational temperature T > 10 mK) is presented and first results on the charge-transfer reaction between OCS+ and ND3 are discussed. Finally, perspectives for further developments of our method are explored.
A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.
This thesis describes the combination of two sources of cold atomic or molecular species which can be used to study a wide range of ion-molecule reactions. The challenges in forming these species and in determining the fate of reactive events are explored throughout. Reactions occur in a volume within a radio-frequency ion trap, in which ions have previously been cooled to sub-Kelvin temperatures. Ions are laser-cooled, with migration of ions slowed sufficiently to form a quasi-crystalline spheroidal structure, deemed a Coulomb crystal. Fluorescence emitted as a consequence of laser-cooling is detected; the subsequent fluorescence profiles are used to determine the number of ions in the crystal and, in combination with complementary simulations, the temperature of these ions. Motion imparted by trapping fields can be substantial and simulations are required to accurately determine collision energies. A beam of decelerated molecules is aimed at this stationary ion target. An ammonia seeded molecular beam enters a Stark decelerator, based on the original design of Meijer and co-workers. The decelerator uses time-varying electric fields to remove kinetic energy from the molecules, which exit at speeds down to 35 m/s. A fast-opening shutter and focussing elements are subsequently used to maximise the decelerated flux in the reaction volume while minimising undecelerated molecule transmission. Substantial fluxes of decelerated ammonia are obtained with narrow velocity distributions to provide a suitable source of reactant molecules. Combination of these two techniques permits studies of reactions between atomic ions and decelerated molecules that can be entirely state-specific. Changes in the Coulomb crystal fluorescence profile denote changes in the ion identities, the rate of these changes can be used to obtain rate constants. Determination of rate constants is even possible despite the fact that neither reactant nor product ions are directly observed. This work has studied reactions between sympathetically cooled Xe+ ions and guided ND3 and has obtained data consistent with prior studies. Determination of reactive events is complicated if ion identities can change without affecting the fluorescence profile, or if multiple reaction channels are possible. A range of spectroscopic techniques are discussed and considered in regards to determining rate constants and product identities. Pulsed axial excitation of trapped ions can follow rapid changes in average ion weights and subtle changes for small crystals. Time-of-flight mass spectrometry is also demonstrated using the trapping electrodes and is suitable for discrimination of ions formed within the trap.
We report a new experimental method to study reactive ion-molecule collisions at very low temperatures. A source of laser-cooled ions in a linear Paul trap has been combined with a quadrupole-guide velocity selector to investigate the reaction of Ca+ with CH3F at collision energies E[over](coll)/k(B)> or =1 K with single-particle sensitivity. The technique represents a general approach to study reactive collisions between ions and polar molecules over a wide temperature range down to the cold regime.
This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.