Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cambridge University Press eBooks

Linear measurements

Vladimir B. Braginsky, Farid Ya Khalili, Kip S. Thorne

Published Sep 24, 1992• 0 citations
Publisher
DOI
10.1017/cbo9780511622748.008

Related papers

Measurability in Linear and Non-Linear Quantum Mechanical Systems

Yakir Aharonov, Benni Reznik

The measurability by means of continuous measurements, of an observable $\A(t_0)$, at an instant, and of a time averaged observable, $\bar \A=1/T\int \A(t')dt'$, is examined for linear and in particular for non-linear quantum mechanical systems. We argue that only when the exact (non-perturbative) solution is known, an exact measurement may be possible. A perturbative approach is shown to fail in the non-linear case for measurements with accuracy $Δ\bar \A < Δ\bar \A_{min}(T)$, giving rise to a restriction on the accuracy. Thus, in order to prepare an initial pure state of a non-linear system, by means of a continuous measurement, the exact non-perturbative solution must be known.

arXiv:quant-ph/9704001•Apr 1, 1997•3 citations

Continuous linear measurements

Vladimir B. Braginsky, Farid Ya Khalili, Kip S. Thorne

Cambridge University Press eBooks•Sep 24, 1992•1 citation

Transit effects for non-linear index measurement in hot atomic vapors

Tangui Aladjidi, Murad Abuzarli, G. Brochier +4 more

Hot atomic vapors are widely used in non-linear and quantum optics due to their large Kerr non-linearity. While the linear refractive index and the transmission are precisely measured and well modeled theoretically, similar characterization remains partial for the $χ^{(3)}$ non-linear part of the susceptibility. In this work, we present a set of tools to measure and estimate numerically the non-linear index of hot atomic vapors both in the steady state and during the transient response of the medium. We apply these techniques for the characterization of a hot vapor of rubidium and we evidence the critical role played by transit effects, due to finite beam sizes, in the measurement of the non-linear index.

arXiv:2202.05764•Feb 11, 2022•9 citations

Statistics in measurements

Shiro Ishikawa

Fuzzy Sets and Systems•Dec 1, 2000•30 citations

Measurement

Paul Busch, PEKKA J. LAHTI, Juha-Pekka Pellonpää +1 more

Theoretical and mathematical physics•Jan 1, 2016•2 citations

Characterization of a measurement-based noiseless linear amplifier and its applications

Jie Zhao, Jing Yan Haw, Thomas Symul +2 more

A noiseless linear amplifier (NLA) adds no noise to the signals it processes, which works only in a probabilistic way. It can be realized approximately with either a physical implementation that truncates the working space of the NLA on a photon-number basis or a measurement-based implementation that realizes the truncation virtually by a bounded postselection filter. To examine the relationship between these two approximate NLAs, we characterize in detail the measurement-based NLA and compare it with its physical counterpart in terms of their abilities to preserve the state Gaussianity and their probability of success. The link between these amplifiers is further clarified by integrating them into a measure-and-prepare setup. We stress the equivalence between the physical and the measurement-based approaches holds only when the effective parameters, the amplification gain, the cutoff, and the amplitude of the input state, are taken into account. Finally, we construct a 1-to-infinity cloner using the two amplifiers and show that a fidelity surpassing the no-cloning limit is achievable with the measurement-based NLA.

Physical Review A•Jul 13, 2017•31 citations
The measurability by means of continuous measurements, of an observable $\A(t_0)$, at an instant, and of a time averaged observable, $\bar \A=1/T\int \A(t')dt'$, is examined for linear and in particular for non-linear quantum mechanical systems. We argue that only when the exact (non-perturbative) solution is known, an exact measurement may be possible. A perturbative approach is shown to fail in the non-linear case for measurements with accuracy $Δ\bar \A < Δ\bar \A_{min}(T)$, giving rise to a restriction on the accuracy. Thus, in order to prepare an initial pure state of a non-linear system, by means of a continuous measurement, the exact non-perturbative solution must be known.
Hot atomic vapors are widely used in non-linear and quantum optics due to their large Kerr non-linearity. While the linear refractive index and the transmission are precisely measured and well modeled theoretically, similar characterization remains partial for the χ(3)χ^{(3)}χ(3) non-linear part of the susceptibility. In this work, we present a set of tools to measure and estimate numerically the non-linear index of hot atomic vapors both in the steady state and during the transient response of the medium. We apply these techniques for the characterization of a hot vapor of rubidium and we evidence the critical role played by transit effects, due to finite beam sizes, in the measurement of the non-linear index.
A noiseless linear amplifier (NLA) adds no noise to the signals it processes, which works only in a probabilistic way. It can be realized approximately with either a physical implementation that truncates the working space of the NLA on a photon-number basis or a measurement-based implementation that realizes the truncation virtually by a bounded postselection filter. To examine the relationship between these two approximate NLAs, we characterize in detail the measurement-based NLA and compare it with its physical counterpart in terms of their abilities to preserve the state Gaussianity and their probability of success. The link between these amplifiers is further clarified by integrating them into a measure-and-prepare setup. We stress the equivalence between the physical and the measurement-based approaches holds only when the effective parameters, the amplification gain, the cutoff, and the amplitude of the input state, are taken into account. Finally, we construct a 1-to-infinity cloner using the two amplifiers and show that a fidelity surpassing the no-cloning limit is achievable with the measurement-based NLA.