Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Study on operating point controlled superconductive TES microcalorimeters

伸幸 全

Published Jan 1, 2007• 0 citations
OpenAlex

Related papers

A Predictive Control Algorithm for Time-Division-Multiplexed Readout of TES Microcalorimeters

Malcolm Durkin, G. C. O’Neil, William Bertrand Doriese +8 more

Journal of Low Temperature Physics•Jan 28, 2020•9 citations

Characteristic measurements of a low-power SQUID for TES microcalorimeter

Sayaka Yoshida, Keisuke Maehata, Shota Yoshimoto +2 more

The Japan Society of Applied Physics•Feb 8, 2016•0 citations

Development of superconducting transition edge sensor microcalorimeters

R. M. T. Damayanthi

•Jan 1, 2009•0 citations

Design of the Microwave SQUID Multiplexer for Fast TES X-ray Microcalorimeter Arrays

Yuki Nakashima, Fuminori Hirayama, Satoshi Kohjiro +4 more

IEICE Technical Report; IEICE Tech. Rep.•Oct 19, 2016•0 citations

Development of X-ray microcalorimeters with mono-layered superconducting transition edge sensors

Yoshihiko Noguchi, Daiji Fukuda, Masashi ONO +17 more

•Sep 1, 2001•0 citations

Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID

Y. Nakashima, Fuminori Hirayama, Satoshi Kohjiro +5 more

We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we have developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics are evaluated, and the results have shown that the distortion of the SQUID characteristics and the degradation of its noise performance are not clearly observed. Finally, we have developed an MW-Mux microstrip SQUID with a low current noise of <; 20 pA/√(Hz) which is below the typical noise of our TES X-ray microcalorimeter, 30 pA/√(Hz).

IEEE Transactions on Applied Superconductivity•Mar 21, 2019•8 citations
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we have developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics are evaluated, and the results have shown that the distortion of the SQUID characteristics and the degradation of its noise performance are not clearly observed. Finally, we have developed an MW-Mux microstrip SQUID with a low current noise of <; 20 pA/√(Hz) which is below the typical noise of our TES X-ray microcalorimeter, 30 pA/√(Hz).