Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Reduced spin measurement back-action for a phase sen- sitivity ten times beyond the standard quantum limit: sup- plementary information

Justin Bohnet, Kevin C. Cox, Matthew A. Norcia, Joshua M. Weiner, Zilong Chen, James K. Thompson

Published Jan 1, 2014• 1 citation
OpenAlex

Related papers

Reduced spin measurement back-action for a phase sensitivity ten times beyond the standard quantum limit

Justin Bohnet, Kevin C. Cox, Matthew A. Norcia +3 more

arXiv:1310.3177•Nature Photonics•Jul 11, 2014•183 citations

Tracking the evolution of a quantum state beyond classical limits

Giorgio Colangelo, Ferran Martin Ciurana, R. J. Sewell +1 more

Summary form only given. Continuous monitoring or tracking of a quantum system is essential to high-sensitivity measurement of time-varying quantities. We estimate spin precession of a magnetically-sensitive atomic ensemble by measuring spin projectors Fαat different times. Such projectors do not commute, and thus quantum measurement back-action (QMBA) necessarily enters the spin measurement record, introducing errors and limiting sensitivity. We show how to reduce this disturbance below δFα~ √N, the classical limit for N spins, by directing the QMBA almost entirely into an unmeasured spin component. This generates a planar squeezed state [1, 2] which allows simultaneous precise knowledge of spin angle and amplitude. We use high-dynamic-range optical quantum non-demolition measurements applied to a precessing magnetic spin ensemble, to demonstrate spin tracking with steady-state angular sensitivity 2.9 dB beyond the standard quantum limit, simultaneous with amplitude sensitivity 7.0 dB beyond Poisson statistics, surpassing classical limits in non-commuting observables for the first time [3]. Our method is close to practical application in high-performance atomic sensors, such as magnetometers and clocks, and is compatible with multi-pass and cavity build-up methods.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Force Sensing Beyond the Standard Quantum Limit in a Hybrid Optomechanical Platform

Alolika Roy, Amarendra K. Sarma

We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.

quant-pharXiv:2512.20081•Journal of the Optical Society of America B•Dec 24, 2025•0 citations

Information extraction and back-action in quantum measurements

Anders Karlsson, Gunnar G. Bjork

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•0 citations

Quantum limits encountered in atomic spin measurements

Jens Lykke Sørensen, Brian Julsgaard, C. Schori +1 more

Spectrochimica Acta Part B Atomic Spectroscopy•Jun 1, 2003•2 citations

Generating entanglement between atomic spins with low-noise probing of an optical cavity

Kevin C. Cox, Joshua M. Weiner, Graham P. Greve +1 more

Atomic projection noise limits the ultimate precision of all atomic sensors, including clocks, inertial sensors, magnetometers, etc. The independent quantum collapse of N atoms into a definite state (for example spin up or down) leads to an uncertainty ΔθSQL= 1/√N in the estimate of the quantum phase accumulated during a Ramsey sequence or its many generalizations. This phase uncertainty is referred to as the standard quantum limit. Creating quantum entanglement between the N atoms can allow the atoms to partially cancel each other's quantum noise, leading to reduced noise in the phase estimate below the standard quantum limit. Recent experiments have demonstrated up to 10 dB of phase noise reduction relative to the SQL by making collective spin measurements. This is achieved by trapping laser-cooled Rb atoms in an optical cavity and precisely measuring the shift of the cavity resonance frequency by an amount that depends on the number of atoms in spin up. Detecting the probe light with high total efficiency reduces excess classical and quantum back-action of the probe. Here we discuss recent progress and a technique for reducing the relative frequency noise between the probe light and the optical cavity, a key requirement for further advances.

arXiv:1504.05160•Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•7 citations
Summary form only given. Continuous monitoring or tracking of a quantum system is essential to high-sensitivity measurement of time-varying quantities. We estimate spin precession of a magnetically-sensitive atomic ensemble by measuring spin projectors Fαat different times. Such projectors do not commute, and thus quantum measurement back-action (QMBA) necessarily enters the spin measurement record, introducing errors and limiting sensitivity. We show how to reduce this disturbance below δFα~ √N, the classical limit for N spins, by directing the QMBA almost entirely into an unmeasured spin component. This generates a planar squeezed state [1, 2] which allows simultaneous precise knowledge of spin angle and amplitude. We use high-dynamic-range optical quantum non-demolition measurements applied to a precessing magnetic spin ensemble, to demonstrate spin tracking with steady-state angular sensitivity 2.9 dB beyond the standard quantum limit, simultaneous with amplitude sensitivity 7.0 dB beyond Poisson statistics, surpassing classical limits in non-commuting observables for the first time [3]. Our method is close to practical application in high-performance atomic sensors, such as magnetometers and clocks, and is compatible with multi-pass and cavity build-up methods.
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.
Atomic projection noise limits the ultimate precision of all atomic sensors, including clocks, inertial sensors, magnetometers, etc. The independent quantum collapse of N atoms into a definite state (for example spin up or down) leads to an uncertainty ΔθSQL= 1/√N in the estimate of the quantum phase accumulated during a Ramsey sequence or its many generalizations. This phase uncertainty is referred to as the standard quantum limit. Creating quantum entanglement between the N atoms can allow the atoms to partially cancel each other's quantum noise, leading to reduced noise in the phase estimate below the standard quantum limit. Recent experiments have demonstrated up to 10 dB of phase noise reduction relative to the SQL by making collective spin measurements. This is achieved by trapping laser-cooled Rb atoms in an optical cavity and precisely measuring the shift of the cavity resonance frequency by an amount that depends on the number of atoms in spin up. Detecting the probe light with high total efficiency reduces excess classical and quantum back-action of the probe. Here we discuss recent progress and a technique for reducing the relative frequency noise between the probe light and the optical cavity, a key requirement for further advances.