Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement Techniques

Determining the Quantum Characteristics of a Photon Counter Using Power-Calibrated Laser Radiation

A. A. Kovalev, Anatoly A. Liberman, Alexey S. Mikryukov, Sergey A. Moskalyuk, Michael V. Ulanovskii

Published Feb 1, 2016• 0 citations
Publisher
DOI
10.1007/s11018-016-0878-4

Related papers

Quantum counter for far-infrared radiation

H. Lengfellner, Karl Friedrich Renk

Two types of three-level quantum counters, based on the Bloembergen and the inverted scheme, are discussed with respect to their application for up-conversion of far-infrared (FIR) radiation to visible light. It is reported on a tunable quantum counter of the inverted type: in optically pumped ruby, photons at 29 cm-1are absorbed by the transition\bar{E}(2E) →2\bar{A}(2E) and lead to an increased R2- fluorescence radiation. By Zeeman splitting of the2Elevels, tuning of the detected frequency from 29 cm-1to higher and lower frequencies is possible (with 1 cm-1/Tesla). Using the 891-GHz radiation of an HCN laser we determine for the quantum counter a power conversion efficiency of the order of 10-6and a frequency bandwidth of 360 MHz. We find the interesting result that phonon bottleneck due to resonant trapping of 29 cm-1phonons can lead to an increase of the quantum efficiency by orders of magnitude.

IEEE Journal of Quantum Electronics•Jun 1, 1977•10 citations

Classical and quantum techniques for photon metrology

Maria Luisa Rastello

•Jan 1, 2007•0 citations

Photon counting statistics of laser light

Gabriel Bédard

Physics Letters A•May 1, 1967•8 citations

Quantum Calibration of Photon-Number-Resolving Detectors Based on Multi-Pixel Photon Counters

Yujie Cai, Yu Chen, Xiuliang Chen +5 more

In this paper, we reconstructed the positive operator-valued measure (POVM) of a photon-number-resolving detector (PNRD) based on a multi-pixel photon counter (MPPC) by means of quantum detector tomography (QDT) at 791 nm and 523 nm, respectively. MPPC is a kind of spatial-multiplexing PNRD with a silicon avalanche photodiode (Si-APD) array as the photon receiver. Experimentally, the quantum characteristics of MPPC were calibrated at 2 MHz at two different wavelengths. The POVM elements were given by QDT. The fidelity of the reconstructed POVM elements is higher than 99.96%, which testifies that the QDT is reliable to calibrate MPPC at different wavelengths. With QDT and associated Wigner functions, the quantum properties of MPPC can be calibrated more directly and accurately in contrast with those conventional methods of modeling detectors.

Applied Sciences•Jun 29, 2019•10 citations

Observation of photon counting distribution for laser light below threshold

Anders Smith, John A. Armstrong

Physics Letters•Jan 1, 1966•50 citations

Absolute self-calibration of the quantum efficiency of single-photon detectors

Chang Jun-Tao, Ling-An Wu, 中国科学院物理研究所光物理开放实验室,北京 100080

An absolute self-calibration method is proposed for determining the quantum efficiency of a single photon detector which does not require any standard referenc e or a second detector. The method is based on the time correlation of photon pa irs generated in parametric downconversion. A beam of frequency downconverted ph otons is split at a polarizing beamsplitter then recombined at a second beamspli tter, but with a time delay introduced between them so that the two photons of a n original pair enter the detector one by one. The photoelectric pulses from the detector are split into three paths; a compensating delay is introduced into tw o of the paths so that the two signals arrive simultaneously at a coincidence co unter; the third path goes directly to a photon counter. From the ratio of the r eadings of the two counters we can derive the quantum efficiency of the detector . Two methods are given, one for continuous wave lasers and another for high rep etition rate pulsed lasers.

Acta Physica Sinica•Jan 1, 2003•5 citations
Two types of three-level quantum counters, based on the Bloembergen and the inverted scheme, are discussed with respect to their application for up-conversion of far-infrared (FIR) radiation to visible light. It is reported on a tunable quantum counter of the inverted type: in optically pumped ruby, photons at 29 cm-1are absorbed by the transition\bar{E}(2E) →2\bar{A}(2E) and lead to an increased R2- fluorescence radiation. By Zeeman splitting of the2Elevels, tuning of the detected frequency from 29 cm-1to higher and lower frequencies is possible (with 1 cm-1/Tesla). Using the 891-GHz radiation of an HCN laser we determine for the quantum counter a power conversion efficiency of the order of 10-6and a frequency bandwidth of 360 MHz. We find the interesting result that phonon bottleneck due to resonant trapping of 29 cm-1phonons can lead to an increase of the quantum efficiency by orders of magnitude.
In this paper, we reconstructed the positive operator-valued measure (POVM) of a photon-number-resolving detector (PNRD) based on a multi-pixel photon counter (MPPC) by means of quantum detector tomography (QDT) at 791 nm and 523 nm, respectively. MPPC is a kind of spatial-multiplexing PNRD with a silicon avalanche photodiode (Si-APD) array as the photon receiver. Experimentally, the quantum characteristics of MPPC were calibrated at 2 MHz at two different wavelengths. The POVM elements were given by QDT. The fidelity of the reconstructed POVM elements is higher than 99.96%, which testifies that the QDT is reliable to calibrate MPPC at different wavelengths. With QDT and associated Wigner functions, the quantum properties of MPPC can be calibrated more directly and accurately in contrast with those conventional methods of modeling detectors.
An absolute self-calibration method is proposed for determining the quantum efficiency of a single photon detector which does not require any standard referenc e or a second detector. The method is based on the time correlation of photon pa irs generated in parametric downconversion. A beam of frequency downconverted ph otons is split at a polarizing beamsplitter then recombined at a second beamspli tter, but with a time delay introduced between them so that the two photons of a n original pair enter the detector one by one. The photoelectric pulses from the detector are split into three paths; a compensating delay is introduced into tw o of the paths so that the two signals arrive simultaneously at a coincidence co unter; the third path goes directly to a photon counter. From the ratio of the r eadings of the two counters we can derive the quantum efficiency of the detector . Two methods are given, one for continuous wave lasers and another for high rep etition rate pulsed lasers.