A Configurable Surface-Electrode Ion Trap Design for Quantum Information Processing

Wei Liu, Shuming Chen, Ping‐Xing Chen, Wei Wu

Published Dec 1, 2013• 4 citations
Publisher

Abstract

We propose a configurable surface-electrode ion trap design to alleviate the poor reusability of the existing traps. It can architecturally and electrically support 5 mainstream modes by design reuse, thus enhancing the trap reusability and reducing the experiment setup overhead. We also develop a corresponding simulation suite which can optimize trap geometries and calculate trap parameters to control the trapped ion's classic motion. According to our analytical and simulated results, the configurable design can serve as a unified platform for basic research of large-scale quantum information processing.

DOI
10.1088/0256-307x/30/12/123702

Related papers

Guidelines for Designing Surface Ion Traps Using the Boundary Element Method

Seokjun Hong, Minjae Lee, Hongjin Cheon +2 more

Ion traps can provide both physical implementation of quantum information processing and direct observation of quantum systems. Recently, surface ion traps have been developed using microfabrication technologies and are considered to be a promising platform for scalable quantum devices. This paper presents detailed guidelines for designing the electrodes of surface ion traps. First, we define and explain the key specifications including trap depth, q-parameter, secular frequency, and ion height. Then, we present a numerical-simulation-based design procedure, which involves determining the basic assumptions, determining the shape and size of the chip, designing the dimensions of the radio frequency (RF) electrode, and analyzing the direct current (DC) control voltages. As an example of this design procedure, we present a case study with tutorial-like explanations. The proposed design procedure can provide a practical guideline for designing the electrodes of surface ion traps.

Sensors•Apr 28, 2016•27 citations

Monolithic microfabricated ion trap forquantum information processing

Fayaz A. Shaikh

The objective of this research is to design, fabricate, and demonstrate a microfabricated \nmonolithic ion trap for applications in quantum computation and quantum simulation. \nMost current microfabricated ion trap designs are based on planar-segmented surface electrodes. \nAlthough promising scalability to trap arrays containing ten to one hundred ions, \nthese planar designs suffer from the challenges of shallow trap depths, radial asymmetry of \nthe confining potential, and electrode charging resulting from laser interactions with dielectric \nsurfaces. In this research, the design, fabrication, and testing of a monolithic \nand symmetric two-level ion trap is presented. This ion trap overcomes the challenges of \nsurface-electrode ion traps. Numerical electrostatic simulations show that this symmetric \ntrap produces a deep (1 eV for 171Yb+ ion), radially symmetric RF confinement potential. \nThe trap has an angled through-chip slot that allows back-side ion loading and generous \nthrough laser access, while avoiding surface-light scattering and dielectric charging that \ncan corrupt the design control electrode compensating potentials. The geometry of the trap \nand its dimensions are optimized for trapping long and linear ion chains with equal spacing \nfor use with quantum simulation problems and quantum computation architectures.

•Mar 26, 2013•0 citations

A grooved planar ion trap design for scalable quantum information processing

Wei-Bang Ji, Jinyin Wan, Hua-Dong Cheng +1 more

We describe a new electrode design for a grooved surface-electrode ion trap, which is fabricated in printed-circuit-board technology with segmented electrodes. This design allows a laser beam to get through the central groove to avoid optical access blocking and laser scattering from the ion trap surface. The confining potentials are modeled both analytically and numerically. We optimize the radio frequency (rf) electrodes and dc electrodes to achieve the maximum trap depth for a given ion height above the trap electrodes. We also compare our design with the reality ion chip MI I for practical considerations. Comparison results show that our design is superior to MI I. This ion trap design may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers.

Chinese Physics B•Jun 1, 2012•3 citations

Integrated chips and optical cavities for trapped ion quantum information processing

David R. Leibrandt

Quantum information processing is a new and exciting field which uses quantum mechanical systems to perform information processing. At the heart of the excitement are quantum computation - which promises efficient algorithms for simulating physical systems, factoring, and searching unsorted databases - and quantum communication - which provides a provably secure communications protocol. Trapped ions show much promise for achieving large-scale quantum information processing. Experiments thus far have demonstrated small algorithms and entanglement of two remote ions. Current work focuses on scaling to large numbers of ions for quantum computation and interconversion between trapped ions and photons for quantum communication. This thesis addresses some of the challenges facing scaling and interconversion for trapped ion quantum information processing. The first part of the thesis describes the development of scalable, multiplexed ion trap chips for quantum computation. The ion trap chips are based on a new ion trap geometry, called the surface-electrode trap, in which all of the electrodes reside in a single plane. Three generations of surface-electrode traps are designed, fabricated, and tested - culminating with the demonstration of an ion trap chip microfabricated using standard silicon VLSI materials and processes for scalability to small trap size and large arrays of interconnected ion traps. The second part of the thesis presents an experiment that demonstrates cavity cooling, a method of laser cooling the motional state of trapped ions without decohering the internal qubit state.

•Jan 1, 2009•3 citations

Surface-Electrode Ion Trap Development

Timur Abbasov, Sergei A. Zibrov, I. Sherstov

We present a segmented linear surface electrode ion trap design that can be used for various applications in optical clocks and quantum computation based on trapped 171Yb+ ions. Our simulations show that calculated trap depth can reach up to several electronvolts and that the pseudopotential minimum of the trap is located above the trap surface at a distance greater than 80 μm. The described pseudopotential simulations and calculations of different trap parameters can be used to design the planar trap with required parameters. This design could be scaled to store a long chain of ions and used for quantum logic applications as well.

Journal of Experimental and Theoretical Physics Letters•Jul 31, 2023•6 citations

Microfabricated Surface-Electrode Ion Trap for Scalable Quantum Information Processing

Signe Louise Seidelin, John Chiaverini, R. Reichle +13 more

Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.

arXiv:quant-ph/0601173•Physical Review Letters•Jun 30, 2006•457 citations
We propose a configurable surface-electrode ion trap design to alleviate the poor reusability of the existing traps. It can architecturally and electrically support 5 mainstream modes by design reuse, thus enhancing the trap reusability and reducing the experiment setup overhead. We also develop a corresponding simulation suite which can optimize trap geometries and calculate trap parameters to control the trapped ion's classic motion. According to our analytical and simulated results, the configurable design can serve as a unified platform for basic research of large-scale quantum information processing.
Ion traps can provide both physical implementation of quantum information processing and direct observation of quantum systems. Recently, surface ion traps have been developed using microfabrication technologies and are considered to be a promising platform for scalable quantum devices. This paper presents detailed guidelines for designing the electrodes of surface ion traps. First, we define and explain the key specifications including trap depth, q-parameter, secular frequency, and ion height. Then, we present a numerical-simulation-based design procedure, which involves determining the basic assumptions, determining the shape and size of the chip, designing the dimensions of the radio frequency (RF) electrode, and analyzing the direct current (DC) control voltages. As an example of this design procedure, we present a case study with tutorial-like explanations. The proposed design procedure can provide a practical guideline for designing the electrodes of surface ion traps.
The objective of this research is to design, fabricate, and demonstrate a microfabricated \nmonolithic ion trap for applications in quantum computation and quantum simulation. \nMost current microfabricated ion trap designs are based on planar-segmented surface electrodes. \nAlthough promising scalability to trap arrays containing ten to one hundred ions, \nthese planar designs suffer from the challenges of shallow trap depths, radial asymmetry of \nthe confining potential, and electrode charging resulting from laser interactions with dielectric \nsurfaces. In this research, the design, fabrication, and testing of a monolithic \nand symmetric two-level ion trap is presented. This ion trap overcomes the challenges of \nsurface-electrode ion traps. Numerical electrostatic simulations show that this symmetric \ntrap produces a deep (1 eV for 171Yb+ ion), radially symmetric RF confinement potential. \nThe trap has an angled through-chip slot that allows back-side ion loading and generous \nthrough laser access, while avoiding surface-light scattering and dielectric charging that \ncan corrupt the design control electrode compensating potentials. The geometry of the trap \nand its dimensions are optimized for trapping long and linear ion chains with equal spacing \nfor use with quantum simulation problems and quantum computation architectures.
We describe a new electrode design for a grooved surface-electrode ion trap, which is fabricated in printed-circuit-board technology with segmented electrodes. This design allows a laser beam to get through the central groove to avoid optical access blocking and laser scattering from the ion trap surface. The confining potentials are modeled both analytically and numerically. We optimize the radio frequency (rf) electrodes and dc electrodes to achieve the maximum trap depth for a given ion height above the trap electrodes. We also compare our design with the reality ion chip MI I for practical considerations. Comparison results show that our design is superior to MI I. This ion trap design may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers.
Quantum information processing is a new and exciting field which uses quantum mechanical systems to perform information processing. At the heart of the excitement are quantum computation - which promises efficient algorithms for simulating physical systems, factoring, and searching unsorted databases - and quantum communication - which provides a provably secure communications protocol. Trapped ions show much promise for achieving large-scale quantum information processing. Experiments thus far have demonstrated small algorithms and entanglement of two remote ions. Current work focuses on scaling to large numbers of ions for quantum computation and interconversion between trapped ions and photons for quantum communication. This thesis addresses some of the challenges facing scaling and interconversion for trapped ion quantum information processing. The first part of the thesis describes the development of scalable, multiplexed ion trap chips for quantum computation. The ion trap chips are based on a new ion trap geometry, called the surface-electrode trap, in which all of the electrodes reside in a single plane. Three generations of surface-electrode traps are designed, fabricated, and tested - culminating with the demonstration of an ion trap chip microfabricated using standard silicon VLSI materials and processes for scalability to small trap size and large arrays of interconnected ion traps. The second part of the thesis presents an experiment that demonstrates cavity cooling, a method of laser cooling the motional state of trapped ions without decohering the internal qubit state.
We present a segmented linear surface electrode ion trap design that can be used for various applications in optical clocks and quantum computation based on trapped 171Yb+ ions. Our simulations show that calculated trap depth can reach up to several electronvolts and that the pseudopotential minimum of the trap is located above the trap surface at a distance greater than 80 μm. The described pseudopotential simulations and calculations of different trap parameters can be used to design the planar trap with required parameters. This design could be scaled to store a long chain of ions and used for quantum logic applications as well.
Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.