We have measured the rf-bias-current dependence of the \ensuremath{\nu}/2 subharmonic spectral response of planar 300\ifmmode\times\else\texttimes\fi{}300 Nb-Au-Nb proximity-coupled Josephson-junction arrays. The \ensuremath{\nu}/2 subharmonic voltage spectrum was examined at two rf-bias frequencies, \ensuremath{\nu}/${\ensuremath{\nu}}_{\mathit{c}}$\ensuremath{\approxeq}1.4, 2.0 (${\ensuremath{\nu}}_{\mathit{c}}$\ensuremath{\approxeq}120 MHz), and in applied magnetic fields corresponding to f=0,1/2 flux quantum per plaquette. The measurements were compared to analytical predictions for an rf-biased asymmetric superconducting quantum interference device with non-negligble loop inductance and large rf-bias-current amplitudes, based on the resistively shunted Josephson-junction model. Reasonable agreement was found between experiment and theory, suggesting that a possible origin for the observed subharmonic behavior in arrays involves an interplay between array plaquette inductances and junction critical-current variations.
We report measurements made on hybrid arrays consisting of superconducting wires along one direction of a square geometry and Josephson junctions along the perpendicular direction. The differential resistance
Rd across the array as a function of normalized applied flux per plaquette f=\ensuremath{\Phi}/${\mathrm{\ensuremath{\Phi}}}_{0}$ exhibits two distinct types of behavior. When the ratio \ensuremath{\beta}\ensuremath{\equiv}
Lg/
LJ of the geometric inductance of an array plaquette to the Josephson-junction inductance is much less than unity, we observe oscillations in
Rd characteristic of a one-dimensional (1D) N-junction interferometer. However, as \ensuremath{\beta} approaches 1, the simultaneous suppression of interferometer oscillations and emergence of local minima in
Rd at commensurate fields f=p/q (where p and q are integers) signal a crossover to behavior typical of 2D superconducting arrays. To model the experimental system, we have performed simulations of 2D arrays of Josephson junctions made anisotropic by incorporating different coupling in the two perpendicular directions (i.e., anisotropic XY model). In the limit of large anisotropy we find 1D interferometer behavior; as the anisotropy is reduced, we see a crossover to the 2D behavior familiar in isotropic arrays.