Bulletin of the American Physical Society

Superconducting Qubit Readout Using Capture-Disperse-Release of Microwave Field

Eric Mlinar

Published Mar 19, 2013• 0 citations
OpenAlex

Related papers

A new microwave resonator readout scheme for superconducting qubits

Michael Metcalfe

•Jan 1, 2008•2 citations

Catch-Disperse-Release Readout for Superconducting Qubits

Eyob Alebachew Sete, Andrei Galiautdinov, Eric Mlinar +2 more

We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.

arXiv:1302.7020•Physical Review Letters•May 22, 2013•33 citations

Novel microwave readout for phase qubits

Shwetank Kumar, Matthias Steffen, Mary-Beth Rothwell +3 more

Bulletin of the American Physical Society•Mar 17, 2010•0 citations

Sequential Dispersive Measurement of a Superconducting Qubit

Théau Peronnin, Danijela Marković, Quentin Ficheux +1 more

We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.

arXiv:1904.04635•Physical Review Letters•May 7, 2020•24 citations

High fidelity qubit readout with the superconducting low-inductance undulatory galvanometer microwave amplifier

David J. Hover, S. Zhu, Ted Thorbeck +6 more

We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 dB and yields a signal-to-noise ratio improvement of 9 dB over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity.

arXiv:1312.7579•Applied Physics Letters•Apr 14, 2014•23 citations

Multiplexed dispersive readout for the superconducting phase qubit

D. Sank, R. Barends, Joerg Bochmann +16 more

Bulletin of the American Physical Society•Feb 28, 2012•0 citations
We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.
We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.
We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 dB and yields a signal-to-noise ratio improvement of 9 dB over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity.