Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Dispersive qubit measurement using an on-chip parametric amplifier: theory

B. A. Levitan, Saeed I. Khan, Andrew Eddins, D.M. Toyli, Irfan A. Siddiqi, Aashish A. Clerk

Published Mar 3, 2015• 0 citations
OpenAlex

Related papers

Dispersive qubit measurement using an integrated on-chip parametric amplifier

Andrew Eddins, D.M. Toyli, Eli M. Levenson-Falk +4 more

Bulletin of the American Physical Society•Mar 3, 2015•0 citations

Improving the Quality of Heisenberg Back-Action of Qubit Measurements made with Parametric Amplifiers

Katrina Sliwa

•Jan 1, 2016•4 citations

Development of integrated, on-chip microwave amplifiers for superconducting qubit measurement

D.M. Toyli, Andrew Eddins, Eli M. Levenson-Falk +4 more

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

Qubit readout with a directional parametric amplifier

Katrina Sliwa, Baleegh Abdo, A. Narla +5 more

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

Dispersive qubit measurement using an on-chip parametric amplifer

B. A. Levitan

We investigate the quantum measurement physics of a system in which a phase-sensitive parametric amplifier is used to directly measure a qubit to which it is coupled dispersively. By analytic calculation of the signal-to-noise ratio, we show that the amplification properties of the paramp can be exploited to achieve on-chip gain of the qubit readout signal, mitigating the damage done to the measurement rate by circulator added noise and losses in between the readout cavity and any following amplification chain. With a different choice of drive phase, we show that when added noise is not a concern, the squeezing properties of the paramp can be used to enhance the measurement rate relative to a standard dispersive readout by reducing the readout noise without corresponding reduction of qubit signal. We then proceed to calculate the back-action dephasing of the qubit by way of a phase-space technique, and find analytic results valid in the long-time limit while numerically handling the finite-time case. We show how in both operating modes, in the long-time limit, the back-action dephasing of the qubit can be made as small as is allowed by quantum mechanics by using using sufficiently many photons in the measurement, i.e.\@ by using a sufficiently strong coherent measurement drive. Crucially, we find that in the presence of experimentally realistic amounts of added noise, the on-chip gain afforded by such a device can be used to come significantly closer to the quantum limit than is possible with a standard dispersive measurement setup, allowing for efficiencies of ~ 75% under conditions that would yield efficiencies <~ 1 % when applying the usual scheme.

•Jan 1, 2016•0 citations

High-Efficiency Measurement of an Artificial Atom Embedded in a Parametric Amplifier

A. Eddins, John Mark Kreikebaum, D. M. Toyli +7 more

A crucial limit to measurement efficiencies of superconducting circuits comes from losses involved when coupling to an external quantum amplifier.Here, we realize a device circumventing this problem by directly embedding an artificial atom, comprised of a transmon qubit, within a flux-pumped Josephson parametric amplifier.This configuration is able to enhance dispersive measurement without exposing the qubit to appreciable excess backaction.Near-optimal backaction is obtained by engineering the circuit to permit high-power operation that reduces information loss to unmonitored channels associated with the amplification and squeezing of quantum noise.By mitigating the effects of off-chip losses downstream, the on-chip gain of this device produces end-to-end measurement efficiencies of up to 80%.Our theoretical model accurately describes the observed interplay of gain and measurement backaction and delineates the parameter space for future improvement.The device is compatible with standard fabrication and measurement techniques and, thus, provides a route for definitive investigations of fundamental quantum effects and quantum control protocols.

arXiv:1806.05276•Physical Review X•Jan 7, 2019•41 citations
We investigate the quantum measurement physics of a system in which a phase-sensitive parametric amplifier is used to directly measure a qubit to which it is coupled dispersively. By analytic calculation of the signal-to-noise ratio, we show that the amplification properties of the paramp can be exploited to achieve on-chip gain of the qubit readout signal, mitigating the damage done to the measurement rate by circulator added noise and losses in between the readout cavity and any following amplification chain. With a different choice of drive phase, we show that when added noise is not a concern, the squeezing properties of the paramp can be used to enhance the measurement rate relative to a standard dispersive readout by reducing the readout noise without corresponding reduction of qubit signal. We then proceed to calculate the back-action dephasing of the qubit by way of a phase-space technique, and find analytic results valid in the long-time limit while numerically handling the finite-time case. We show how in both operating modes, in the long-time limit, the back-action dephasing of the qubit can be made as small as is allowed by quantum mechanics by using using sufficiently many photons in the measurement, i.e.\@ by using a sufficiently strong coherent measurement drive. Crucially, we find that in the presence of experimentally realistic amounts of added noise, the on-chip gain afforded by such a device can be used to come significantly closer to the quantum limit than is possible with a standard dispersive measurement setup, allowing for efficiencies of ~ 75% under conditions that would yield efficiencies <~ 1 % when applying the usual scheme.
A crucial limit to measurement efficiencies of superconducting circuits comes from losses involved when coupling to an external quantum amplifier.Here, we realize a device circumventing this problem by directly embedding an artificial atom, comprised of a transmon qubit, within a flux-pumped Josephson parametric amplifier.This configuration is able to enhance dispersive measurement without exposing the qubit to appreciable excess backaction.Near-optimal backaction is obtained by engineering the circuit to permit high-power operation that reduces information loss to unmonitored channels associated with the amplification and squeezing of quantum noise.By mitigating the effects of off-chip losses downstream, the on-chip gain of this device produces end-to-end measurement efficiencies of up to 80%.Our theoretical model accurately describes the observed interplay of gain and measurement backaction and delineates the parameter space for future improvement.The device is compatible with standard fabrication and measurement techniques and, thus, provides a route for definitive investigations of fundamental quantum effects and quantum control protocols.