Acta Physica Sinica

Experimental study of laser collimation of Cr beam

Yan Ma, Baowu Zhang, Zheng Chun-Lan, Ma Shan-Shan, Fosheng Li, Wang Zhan-Shan, Tongbao Li, 同济大学物理系,上海 200092

Published Jan 1, 2006• 8 citations
Publisher

Abstract

Laser collimation of Cr atomic beam using a transverse Doppler cooling scheme is studied. The frequency of laser is stabilized at 5±0.26MHz below the 7S3→7PO452Cr transition. The shortest size of the laser cooling beam is computed theoretically to be 13.7mm. Accordingly a Cr beam was collimated using a transverse Doppler cooling scheme. We obtained that the transverse distribution of Cr beam is less than 1/3 of the uncooled beam.

DOI
10.7498/aps.55.4086

Related papers

Studies on a Laser-collimated Chromium Beam

Tongbao Li

Laser collimation of Cr atomic beam was studied using a transverse Doppler cooling scheme.Collimation occured for a laser detuned to the red side of the 7S3→7P04 transition.Many optimized parameters taken from repetitious experiments and calculations are given,and the misalignment between the probe beam was gotten and the collimation beam will lead to the artificial broadening of detected transverse linewidth.Finally the collimation result is got that the transverse divergence of Cr beam is 0.48 mrad,and the transverse temperature is 265 μK.

ACTA PHOTONICA SINICA•Jan 1, 2007•1 citation

Laser Collimation of a Chromium Beam Using Doppler Force

Wentao Zhang, Baohua Zhu, Baowu Zhang +1 more

We report on the collimation of a chromium atomic beam by one-dimensional transverse Doppler laser cooling. Operated on the cycling 7S3→7P(superscript 0 subscript 4) transition at 425.55 nm, the optical molasses laser power was 60 mW, which was detuned 2.5 MHz below the resonant frequency. The angular divergence of the atomic beam was reduced from 4.5 mrad to 0.48 mrad, corresponding to a transverse velocity of ±0.46 m/s, and the relevant transverse temperature is 265 μK.

Chinese Journal of Physics•Feb 1, 2008•1 citation

Experimental measurement study of laser collimation of a chromium beam by Doppler cooling scheme

Wang Lidong, Tongbao Li, Yan Ma +1 more

In this paper,a size detecting system based on Laser induced fluorescence(LIF)is designed to measure the Cr atomic beam divergence of laser collimation by using one-dimensional transverse Doppler cooling scheme.Under the parameters of cooling laser power of 45mW,interaction distance of 24mm and detuning of-0.5Γ,we observe the angular distribution of Cr atoms(50%quantile) on the beam axis is from 1.07±0.10mrad to 0.46±0.10mrad by laser collimation.we also present detailed measurements of collimation angles over different laser powers and compare and analysis our results with numerical calculation based on the semiclassical model.

Jiguang zazhi•Jan 1, 2010•0 citations

Simulations of one-dimensional transverse laser cooling of Cr atomic beam with Monte Carlo method

Baowu Zhang, Pingping Zhang, Yan Ma +1 more

A well collimated atomic beam plays an important role in laser focused Cr atom deposition. The simulations of one-dimensional (1D) transverse laser cooling of Cr atomic beam is performed with the Monte Carlo method. Taking into account the stochastic initial conditions of each atom, isotopes other than 52Cr, longitudinal velocity distribution and transverse divergence, the atomic beam cooled by laser is optimized and evaluated. The obtained results are consistent with experimental. In addition, with picking out the trajectories of isotopes other than 52Cr that are not cooled by the laser the center maximum value can be reduced by 9.3%, and the FWHM is increased by 11% of the transverse distribution.

Acta Physica Sinica•Jan 1, 2011•1 citation

Doppler laser cooling of chromium atom beam

Wentao Zhang, Tongbao Li

We have laser collimated a chromium atomic beam in one dimension using the Doppler laser cooling technique.The experimental setup was given,in which,the laser was tuned 5MHz below the chromium transition by an AOM,the laser was generated by a frequency-doubled single-mode Ti:Sapphire laser.We also modulated the results of cooling.By calculating,the angular divergence of the atomic beam was reduced from 4.5mrad to 0.9mrad.

Journal of Guilin University of Electronic Technology•Jan 1, 2006•1 citation

Laser Collimation of Cr Atoms with 3-D Simulation Analysis

Xianming Xiong, Yanqun Li, Wentao Zhang

Based on two-level atomic theory and Doppler Effect, the laser collimation of Cr atoms with 3-D simulation analysis has been studied in this paper. By analyzing the 3-D force on chromium atom, a theoretical 3-D model is built and the accurate 3-D trajectory of chromium atoms in laser cooling field has been achieved. The final 3-D distribution of atoms with different parameters has also been described.

Journal of Nanoscience and Nanotechnology•Sep 1, 2012•1 citation
Laser collimation of Cr atomic beam using a transverse Doppler cooling scheme is studied. The frequency of laser is stabilized at 5±0.26MHz below the 7S3→7PO452Cr transition. The shortest size of the laser cooling beam is computed theoretically to be 13.7mm. Accordingly a Cr beam was collimated using a transverse Doppler cooling scheme. We obtained that the transverse distribution of Cr beam is less than 1/3 of the uncooled beam.
Laser collimation of Cr atomic beam was studied using a transverse Doppler cooling scheme.Collimation occured for a laser detuned to the red side of the 7S3→7P04 transition.Many optimized parameters taken from repetitious experiments and calculations are given,and the misalignment between the probe beam was gotten and the collimation beam will lead to the artificial broadening of detected transverse linewidth.Finally the collimation result is got that the transverse divergence of Cr beam is 0.48 mrad,and the transverse temperature is 265 μK.
In this paper,a size detecting system based on Laser induced fluorescence(LIF)is designed to measure the Cr atomic beam divergence of laser collimation by using one-dimensional transverse Doppler cooling scheme.Under the parameters of cooling laser power of 45mW,interaction distance of 24mm and detuning of-0.5Γ,we observe the angular distribution of Cr atoms(50%quantile) on the beam axis is from 1.07±0.10mrad to 0.46±0.10mrad by laser collimation.we also present detailed measurements of collimation angles over different laser powers and compare and analysis our results with numerical calculation based on the semiclassical model.
A well collimated atomic beam plays an important role in laser focused Cr atom deposition. The simulations of one-dimensional (1D) transverse laser cooling of Cr atomic beam is performed with the Monte Carlo method. Taking into account the stochastic initial conditions of each atom, isotopes other than 52Cr, longitudinal velocity distribution and transverse divergence, the atomic beam cooled by laser is optimized and evaluated. The obtained results are consistent with experimental. In addition, with picking out the trajectories of isotopes other than 52Cr that are not cooled by the laser the center maximum value can be reduced by 9.3%, and the FWHM is increased by 11% of the transverse distribution.