The 27 Al + ion optical clock is one of the most attractive optical clocks due to its own advantages such as low black-body radiation shift at room temperature and insensitivity to the magnetic drift. However, it cannot be laser-cooled directly in the absence of 167nm laser to date. This problem can be solved by sympathetic cooling. In this work, a linear Paul trap is used to trap both 40 Ca + and 27 Al + ions simultaneously, and a single Doppler-cooled 40 Ca + ion is employed to sympathetically cool a single 27 Al + ion. Thus a 'bright-dark' two-ion crystal has been successfully synthesized. The temperature of the crystal has been estimated to be about 7 mK by measuring the ratio of carrier and sideband spectral intensities. Finally, the dark ion is proved to be an 27 Al + ion by precise measuring of the ion crystal's secular motion frequency, which means that it is a great step for our 27 Al + quantum logic clock.
Coulomb crystals, containing up to a few hundred ions of which more than 50% were cooled sympathetically by the Coulomb interaction with laser cooled Mg+ ions, have been produced in a linear Paul trap. By controlling the balance of the radiation pressure from the two cooling lasers, the Coulomb crystals could be segregated according to ion species. Previous studies of ion crystals and molecular dynamics simulations suggest that the temperature may be around 10 mK or lower. The obtained results indicate that a wide range of atomic and molecular ions, which due to their internal structures are not amenable to direct laser cooling, can be effectively cooled and localized (crystallized) in linear Paul traps. For high resolution spectroscopy of such ions this may turn out to be very useful.
We report on the sympathetic cooling and Coulomb crystallization of xenon highly charged ions (HCIs) with laser-cooled Ca
+ ions. The HCIs are produced in a compact electron beam ion trap, then charge selected, decelerated, and finally injected into a cryogenic linear Paul trap. There, they are captured into
40Ca
+ Coulomb crystals, and co-crystallized within them, causing dark voids in their fluorescence images. Fine control over the number of trapped ions and HCIs allows us to realize mixed-species crystals with arbitrary ordering patterns. By investigating Xe
q+--Ca
+ strings, we confirm the HCI charge states, measure their lifetime and characterize the mixed-species motional modes. Our system effectively combines the established quantum control toolbox for Ca
+ with the rich set of atomic properties of Xe highly charged ions, providing a resourceful platform for optical frequency metrology, searches for signatures of new physics, and quantum information science.
We have created multispecies Coulomb crystals in a linear Paul trap containing up to a few hundred ions of which more than
50 were cooled only sympathetically through the Coulomb interaction with laser-cooled
Mg+ ions. In an extreme case, one laser-cooled ion maintained order in a 15 ion string. Ion species segregation was obtained by radiation pressure. Previous experiments and molecular dynamics simulations suggest the temperature is 10 mK or lower. These results indicate that a wide range of atomic and molecular ions can be cooled and localized in linear Paul traps which is important for improvements in spectroscopic studies of such ions.
We report sympathetic cooling of
113Cd
+ by laser-cooled
40Ca
+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of
113Cd
+ ions was achieved. The temperature of these ions was measured at
90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of
2×10−17. Up to
4.2×105 Cd
+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still
105 Cd
+ ions present, indicating that this Ca
+--Cd
+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca
+ lasers and fluorescence, which was carefully estimated to an accuracy of
5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
An investigation of the sympathetic cooling \nmethod for the studies of large ultra-cold molecular ions in a quadrupole ion trap has been conducted.Molecular dynamics simulations are performed to study the rf heating mechanisms in the ion trap. The dependence of \nrf heating rates on the ion temperature, trapping parameters, \nand the number of ions is obtained. New rf heating mechanism \naffecting ultra-cold ion clouds exposed to laser radiation is described.The saturation spectroscopy setup of the hyperfine spectra \nof the molecular iodine has been built to provide an accurate frequency reference for the laser wavelength. This reference is used to obtain the fluorescence lineshapes of \nthe laser cooled Mg
+ ions under different trapping conditions.The ion temperatures are deduced from the measurements, and \nthe influence of the rf heating rates on the fluorescence lineshapes \nis also discussed. Cooling of the heavy (
m=720a.u.) fullerene ions to under 10K by the means of the sympathetic cooling by the Mg
+ ions(
m=24a.u.) is demonstrated. The single-photon imaging system has been developed and used to obtain the images of the Mg
+ ion crystal structures at mK temperatures.